Skip to main content
Log in

Capacity limitation of nuclear units in grid based on analysis of frequency regulation

  • Research Article
  • Published:
Frontiers in Energy Aims and scope Submit manuscript

Abstract

The increasing capacity of nuclear units in power grid poses threat to system stability and security. Load disturbance may cause overspeed of the units and trigger the overspeed protection controller (OPC). Repeating actions of valves have a strong impact on the security of the equipment and may result in a collapse of the power system. Based on the analysis of frequency regulation, mathematic models for nuclear units in the grid are established in this paper to simulate the dynamic process when load disturbance occurs. The critical action of the OPC is proposed as the constraint of safe operation for the units. The relationship between different styles of frequency regulation and the allowable capacity of the nuclear units in the grid is discussed. This research can help to estimate the capacity limitation of nuclear units in the grid.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Dai Y P, Zhao P, Chang S P. Primary frequency control characteristic of a grid. In: Proceedings of the 3rd IEEE Conference on Industrial Electronics and Applications, Singapore, 2008, 1493–1497

  2. Younkins T D, Johnson L H. Steam turbine overspeed control and behaviour during system disturbances. IEEE Transactions on Power Apparatus and Systems, 1981, PAS-100(5): 2504–2511

    Article  Google Scholar 

  3. Kundur P, Lee D C, Bayne J P, Dandeno P L. Impact of turbine generator overspeed controls on unit performance under system disturbance conditions. IEEE Transactions on Power Apparatus and Systems, 1985, PAS-104(6): 1262–1269

    Article  Google Scholar 

  4. Gao L, Dai Y P. Impact of overspeed protection control on stability for islanded power system. International Journal of Emerging Electric Power Systems, 2009, 10(6): 1–9

    MATH  Google Scholar 

  5. Yu D R, Guo Y F, Xu J Y. The primary frequency regulation stability of parallel turbo-generators. Proceedings of the CSEE, 2000, 20(9): 59–63

    Google Scholar 

  6. Zhang Z Y, Cai Y J. Automatic Control of Turbomachinery. Xi’an: Xi’an Jiaotong University Press, 1993

    Google Scholar 

  7. Guo Y F, Xu Z Q, Yu D R, Zhao T. The design of secondary frequency regulation loop considering regulation dead band. Proceedings of the CSEE, 2004, 24(10): 77–81

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pan Jiang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dai, Y., Jiang, P., Gao, L. et al. Capacity limitation of nuclear units in grid based on analysis of frequency regulation. Front. Energy 6, 148–154 (2012). https://doi.org/10.1007/s11708-012-0174-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11708-012-0174-1

Keywords

Navigation