Abstract
It has become generally accepted that water quality can deteriorate in a distribution system through microbiological and chemical reactions in the bulk phase and/or at the pipe wall. The most serious aspect of water quality deterioration in a network is the loss of the disinfectant residual that can weaken the barrier against microbial contamination. Studies have suggested that one factor contributing to the loss of disinfectant residuals is the reaction between bulk phase disinfectants and pipe wall material. Free chlorine loss in corroded metal and PVC pipes, subject to changes in velocity, was assessed during an experiment conducted under controlled conditions in a specially constructed pipe loop located at the US Environmental Protection Agency’s (EPA’s) Test and Evaluation (T&E) Facility in Cincinnati, Ohio (USA). These studies demonstrated that in older unlined metal pipes, the loss of chlorine residual increases with velocity but that wall demand in PVC was negligible.
Similar content being viewed by others
References
Al-Jasser A O (2007). Chlorine decay in drinking-water transmission and distribution systems: Pipe service age effect. Water Res, 41(2): 387–396
Benjamin M M, Sontheimer H, Leroy P (1996). Corrosion of iron and steel. Internal Corrosion of Water Distribution Systems, American Water Works Association Research Foundation/DVGW-Technologiezentrum Wasser, 29–77
Biswas P, Lu C, Clark R M (1993). A model for chlorine concentration decay in pipes. Water Res, 27(12): 1715–1724
Clark R M, Coyle J A (1990). Measuring and modeling variations in distribution system water quality. J Am Water Works Assoc, 82(8): 46–53
Clark R M, Grayman W M, Goodrich J A, Deininger R A, Hess A F (1991). Field testing distribution water quality models. J Am Water Works Assoc, 83(7): 67–75
Clark R M, Haught R C (2005). Characterizing pipe wall demand: Implications for water quality. J Water Resour Plan Manage, 131(3): 208–217
Clark R M, Haught R C, Panguluri S, Roman W (2006). Predicting the Loss of Chlorine and Chloramine Residuals in Metallic Pipes. In: Proceedings of the 8th Annual Water Distribution Systems Analysis Symposium, Cincinnati, USA, August 27th–30th
Clark R M, Rossman L, Wymer L (1995). Modeling distribution system water quality: Regulatory implications. JWater Resour Plan Manage, 121(6):423–428
Clark RM, Smalley G, Goodrich J A, Tull R, Rossman L A, Vasconcelos J, Boulos P (1994). Managing water quality in distribution systems: Simulating TTHM and chlorine residual propagation. J Water Supply, 43(4): 182–191
Clark R M, Yang Y J, Impellitteri C A, Haught R C, Schupp D A, Panguluri S, Krishnan E R (2010). Chlorine fate and transport in distribution systems: Experimental and modeling studies. J Am Water Works Assoc, 102(5): 144–155
Digiano F A, Zhang W (2005). Pipe section reactor to evaluate chlorine-Wall reaction. Journal AWWA, 97(1): 74–85
Doshi P E, Grayman W M, Guastella D (2003). Field Testing the Chlorine Wall Demand in Distribution Mains. In: Proceedings of the 2003 Annual Conference of the American Water Works Association, American Water Works Association, Denver, USA, 1–10
Grayman W M, Rossman L A, Gill M A, Li Y, Guastella D E (2002). Measuring and Modeling Disinfectant Wall Demand in Metallic Pipes. In: Proceedings of the EWRI Conference on Water Resources Planning and Management, Reston VA, ASCE
Panguluri S, Yang Y J, Haught R C, Clark R M, Krishnan E R, Schupp D A (2007). Tracer Dispersion Studies for Hydraulic Characterization of Pipes. In: Proceedings of the Water Environmental and Water Resources Congress, EWRI 2007, Tampa, USA, May15th–19th
Powell J C (1998). Modeling chlorine in water distribution networks. A thesis submitted to the faculty of Engineering at the University of Birmingham for the degree of Doctor of Philosophy
Rossman L A, Brown R A, Singer P C, Nuckols J R (2001). DBP formation kinetics in a simulated distribution system. Water Res, 35(14): 3483–3489
Rossman L A, Clark R M, Grayman W M (1994). Modeling chlorine residuals in drinking water distribution systems. J Environ Eng, 120(4): 803–820
Vasconcelos J J, Rossman L A, Grayman W M, Boulos P F, Clark R M (1997). Kinetics of chlorine decay. J Am Water Works Assoc, 89(7): 54–65
Williams D B (1958). Dechlorination linked to corrosion in water distribution systems. Water and Sewage Works, 106–111
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Clark, R.M. Chlorine fate and transport in drinking water distribution systems: Results from experimental and modeling studies. Front. Earth Sci. 5, 334–340 (2011). https://doi.org/10.1007/s11707-011-0194-x
Received:
Accepted:
Published:
Issue Date: