Abstract
This study describes a novel exposure technique for base of tongue trans-oral robotic surgery (BOT TORS) and early experience with it. The technique discussed involves placement of a suture through the mobile tongue with distraction and suspension of the tongue to the operating table. TORS is then performed per previously described techniques. In our series, 13 patients with either benign or malignant mass lesions involving the tongue base were treated with TORS at a tertiary academic medical center. We reviewed the rates of adequate exposure, console time, adequacy of resection (in malignant cases), complication rates, and costs associated with this technique. In our series, adequate exposure was achieved in 92.3 % of patients. Mean console time was 36 min. Negative surgical margins were achieved in all cancer resections. Five minor complications (tongue lacerations) were observed. Per-case cost attributable to this technique is $3.81. We conclude that BOT TORS is feasible without the use of a mouth prop. Operative times are consistent with those reported by centers that routinely use mouth props for BOT TORS. This technique does not appear to compromise margin adequacy during oncologic resections. Its use may result in a significant cost savings when compared to the FK and other similar retractors.
Similar content being viewed by others
References
O’Malley BW, Weinstein GS, Snyder W, Hockstein NG (2006) Transoral robotic surgery (TORS) for base of tongue neoplasms. Laryngoscope 116:1465–1472
Genden EM, Desai S, Sung CK (2009) Transoral robotic surgery for the management of head and neck cancer: a preliminary experience. Head Neck 31:283–289
Moore EJ, Olsen KD, Kasperbauer JL (2009) Transoral robotic surgery for oropharyngeal squamous cell carcinoma: a prospective study of feasibility and functional outcomes. Laryngoscope 119:2156–2164
Hurtuk A, Agrawal A, Old M et al (2011) Outcomes of transoral robotic surgery: a preliminary clinical experience. Otolaryngol Head Neck Surg 145:248–253
Remacle M, Matar N, Lawson G, Bachy V (2011) Laryngeal advanced retractor system: a new retractor for transoral robotic surgery. Otolaryngol Head Neck Surg 145:696–697
Weinstein GS, O’Malley BW, Magnuson JS et al (2012) Transoral robotic surgery: a multicenter study to assess feasibility, safety, and surgical margins. Laryngoscope 122:1701–1707
Lawson G, Remacle M, Matar N et al (2011) Transoral robotic surgery for the management of head and neck tumors: learning curve. Eur Arch Otorhinolaryngol 268:1795–1801
Cognetti DM, Luginbuhl AJ, Nguyen AL, Curry JM (2012) Early adoption of transoral robotic surgery program: preliminary Outcomes. Otolaryngol Head Neck Surg 147:482–488
Jonson PJ, Rivera-Serrano CM, Castro M et al (2013) Demonstration of transoral surgery in cadaveric specimens with the medrobotics flex system. Laryngoscope 123:1168–1172
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Dr. Miller declares that he has no conflict of interest.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Rights and permissions
About this article
Cite this article
Miller, M.C. Tongue base exposure during TORS without the use of a mouth prop. J Robotic Surg 10, 347–352 (2016). https://doi.org/10.1007/s11701-016-0609-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11701-016-0609-5