Teflon-coated magnetic stir bars are suspected to be a source of impurities for the laboratory blank solutions. To evaluate the ability of magnetic bars to absorb and release different elements at sub-ppb and above-ppb (µg L−1) level, the experiment with new and used bars was conducted. The bars were subjected to microwave-assisted acid digestion with the soil sample and a series of successive cleaning procedures. The spectrometry analysis of the obtained extracts revealed that most of the elements may be released during subsequent extractions in the ppb-level concentrations, whereas the following elements: Cr, Cu, Sb, Sn, and Pb may be extracted even in elevated concentrations. Electronic microscope inspection of Teflon surfaces demonstrated the multiple defects that probably increase the absorption of the elements. We concluded that the concentration of mineral impurities in the laboratory blank solution prepared in the randomly selected one vessel per sample preparation batch is hardly propagated to the other used vessels. The alternative concept "blank per vessel" was proposed especially for ultra-trace analysis. Also, an additional step in the bar washing procedure was proposed.
Graphical abstract
References
Richter RC, Nobrega JA, Pirola C (2016) Think blank: clean chemistry tools for atomic spectroscopy. Ikonos, Italy. https://milestonesci.com/wp-content/uploads/2017/09/Think_Blank_EBook.pdf. Accessed 24 August 2021
Michel T, Potter D (2011) Clean chemistry tools: what it takes to achieve the low analytical blanks necessary to produce good ICP/ICP-MS data. Lab Manag Issue 6:24–27
Pentsak EO, Eremin DB, Gordeev EG, Ananikov VP (2019) Phantom reactivity in organic and catalytic reactions as a consequence of microscale destruction and contamination-trapping effects of magnetic stir bars. ACS Catal 9(4):3070–3081. https://doi.org/10.1021/acscatal.9b00294
EPA (1994) Method 200.8: Determination of trace elements in waters and wastes by inductively coupled plasma-mass spectrometry. Revision 5.4. https://www.epa.gov/sites/default/files/2015-06/documents/epa-200.8.pdf. Accessed 22 Sept 2021.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors have no relevant financial or non-financial interests to disclose. The authors have no competing interests to declare that are relevant to the content of this article. All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest or non-financial interest in the subject matter or materials discussed in this manuscript. The authors have no financial or proprietary interests in any material discussed in this article.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Rosen, V.V., Andrushchenko, Y., Zelinger, E. et al. The magnetic stir bar as a source of impurities in laboratory blank solutions of the environmental samples subjected to microwave-assisted acid digestion. Chem. Pap. 76, 5985–5990 (2022). https://doi.org/10.1007/s11696-022-02276-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11696-022-02276-z