Abstract
Voltammetric behavior of the antineoplastic drug 5-fluorouracil is for the first time studied on polished copper solid amalgam electrode. It was proved that the presence of the copper in the electrode material is advantageous for the determination of 5-fluorouracil, and one well-developed cathodic signal belonging to the reduction of the absorbed complex of 5-fluorouracil–Cu(II) was found as suitable for its precise determination. The highest response was recorded in Britton–Robinson buffer of pH 8 and excellent results like repeatability of measurements and determination as well or limit of detection (1.2 × 10−9 mol L−1) were reached. Moreover, the proposed method was successfully applied to the analysis of pharmaceutical sample with excellent recovery (97.0–100.9%).
Similar content being viewed by others
References
Alanazi FK, Yassin AE, El-Badry M, Mowafy HA, Alsarra IA (2009) Validated high-performance liquid chromatographic technique for determination of 5-fluorouracil: applications to stability studies and simulated colonic media. J Chromatogr Sci 47:558–563. doi:10.1093/chromsci/47.7.558
Badea I, Moja D, Tudose A, Stoicescu D (2002) Determination of the 5-fluorouracil and N1(2′-furanidyl)uracil in the presence of tegafur by zero-crossing first derivative spectrometry. J Pharm Biomed Anal 30:1371–1378. doi:10.1016/S0731-7085(02)00436-3
Bandžuchová L, Šelešovská R, Navrátil T, Chýlková J (2013a) Sensitive voltammetric method for determination of herbicide triasulfuron using silver solid amalgam electrode. Electrochim Acta 113:1–8. doi:10.1016/j.electacta.2013.09.077
Bandžuchová L, Šelešovská R, Navrátil T, Chýlková J (2013b) Silver solid amalgam electrode as a tool for monitoring the electrochemical reduction of hydroxocobalamin. Electroanalysis 25:213–222. doi:10.1002/elan.201200365
Bouzid B, MacDonald AMG (1988) Polarographic study of uracil derivatives. Anal Chim Acta 211:155–173. doi:10.1016/S0003-2670(00)83677-6
Buckpitt AR, Boyd MR (1980) A sensitive method for determination of 5-fluorouracil and 5-fluoro-2′-deoxyuridine in human plasma by high-pressure liquid chromatography. Anal Biochem 106:432–437. doi:10.1016/0003-2697(80)90544-8
Cameron DA, Gabra H, Leonard RCF (1994) Continuous 5-fluorouracil in the treatment of breast cancer. Br J Cancer 70:120–124. doi:10.1038/bjc.1994.259
Casale F, Canaparo R, Muntoni E, Serpe L, Zara GP, Pepa CD, Berno E, Costa M, Eandi M (2002) Simultaneous HPLC determination of 5-fluorouracil and its metabolites in plasma of cancer patients. Biomed Chromatogr 16:446–452. doi:10.1002/bmc.181
Cataldi TRI, Guerrieri A, Palmisano F, Zambonin PG (1988) Determination of the anticancer drug 5-fluorouracil added to blood serum by liquid chromatography with anodic amperometric detection. Anal Chim Acta 207:183–194. doi:10.1016/S0003-2670(00)80794-1
Chen W, Shen Y, Rong H, Lei L, Guo S (2012) Development and application of a validated gradient elution HPLC method for simultaneous determination of 5-fluorouracil and paclitaxel in dissolution samples of 5-fluorouracil/paclitaxel-co-eluting stents. J Pharm Biomed Anal 59:179–183. doi:10.1016/j.jpba.2011.10.005
Chorti P, Fischer J, Vyskočil V, Economou A, Barek J (2014) Voltammetric determination of insecticide thiamethoxam on silver solid amalgam electrode. Electrochim Acta 140:5–10. doi:10.1016/j.electacta.2014.01.081
Christian GD, Purdy WC (1961) A polarographic study of copper complexes with some cancer chemotherapeutic agents. Biochim Biophys Acta 54:587–588. doi:10.1016/0006-3002(61)90103-2
Daňhel A, Barek J (2011) Amalgam electrodes in organic electrochemistry. Curr Org Chem 15:2957–2969. doi:10.2174/138527211798357218
Daňhel A, Raindlová V, Havran L, Pivoňková H, Hocek M, Fojta M (2014) Electrochemical behaviour of 2,4-dinitrophenylhydrazi(o)ne as multi-redox centre DNA label at mercury meniscus modified silver solid amalgam electrode. Electrochim Acta 126:122–131. doi:10.1016/j.electacta.2013.09.147
de Bono JS, Twelves CJ (2001) The oral fluorinated pyrimidines. Invest New Drugs 19:41–59. doi:10.1023/A:1006404701008
de Souza D, de Toledo RA, Mazo LH, Machado SAS (2005) Utilization of a copper solid amalgam electrode for the analytical determination of atrazine. Electroanalysis 17:2090–2094. doi:10.1002/elan.200503331
de Souza D, de Toledo RA, Sufredini HB, Mazo LH, Machado SAS (2006) Characterization and use of copper solid amalgam electrode for electroanalytical determination of triazines-based herbicides. Electroanalysis 18:605–612. doi:10.1002/elan.200503441
Gebrosky NP, Koukol S, Nseyo UO, Carpenter C, Lamm DL (1997) Treatment of renal cell carcinoma with 5-fluorouracil and alfa-interferon. Urology 50:863–868. doi:10.1016/S0090-4295(97)00542-6
Guerrieri A, Cataldi TRI, Palmisano F, Zambonin PG (1991) The anodic behavior of mercury in the presence of 5-fluorouracil—an electroanalytical study. J Electroanal Chem 314:117–134. doi:10.1016/0022-0728(91)85432-O
Gui R, Wan A, Jinm H (2013) Facile synthesis of quantum dots/mesoporous silica/quantum dots core/shell/shell hybrid microspheres for radiometric fluorescence detection of 5-fluorouracil in human serum. Analyst 138:5956–5964. doi:10.1039/C3AN01089A
Hansova B, Synek S, Opatrilova R (2011) 5-Fluorouracil—characteristics and analytical determination. Curr Pharm Anal 7:1–11. doi:10.2174/157341211794708767
Heidelberger C, Chaudhuri NK, Danneberg P, Mooren D, Griesbach L, Duschinsky R, Schnitzer RJ, Pleven E, Scheiner J (1957) Fluorinated pyrimidines, a new class of tumour-inhibitory compounds. Nature 179:663–665. doi:10.1038/179663a0
Heyrovský J (1922) Elektrysa se rtuťovou kapkovou kathodou. Chemické Listy 16:256–264
Horáková E, Šmídová D, Vyskočil V, Barek J (2015) Voltammeric determination of 2-nitrobiphenyl and 4-nitrobiphenyl using a mercury meniscus modified silver solid amalgam electrode. Int J Electrochem Sci 10:2155–2169
Huynh TP, Pieta P, D´Souza F, Kutner W (2013) Molecularly imprinted polymer for recognition of 5-fluorouracil by RNA-type nucleobase pairing. Anal Chem 85:8304–8312. doi:10.1021/ac401598k
Jelen F, Yosypchuk B, Kouřilová A, Novotný Y, Paleček E (2002) Label-free determination of picogram quantities of DNA by stripping voltammetry with solid copper amalgam or mercury electrodes in the presence of copper. Anal Chem 74:4788–4793. doi:10.1021/ac0200771
Jiangli Y, Chongjie Z, Guogong P, Erkang W (1993) Differential pulse stripping voltammetry of cancerostatic 5-fluorouracil and determination in blood serum. Bioelectrochem Bioenerg 29:347–355. doi:10.1016/0302-4598(93)85009-I
Joulia JM, Pinguet F, Grosse PY, Astre C, Bressolle F (1997) Determination of 5-fluorouracil and its main metabolites in plasma by high-performance liquid chromatography: application to a pharmacokinetic study. J Chromtaogr B 692:427–435. doi:10.1016/S0378-4347(96)00518-X
Khodari M (1998) Determination of cadmium in seawater by cathodic stripping voltammetry of complexes with 5-fluorouracil. Electroanalysis 10:1061–1063. doi:10.1002/(SICI)1521-4109(199810)10:15<1061:AID-ELAN1061>3.0.CO;2-2
Khodari M, Ghandour M, Taha AM (1997) Cathodic stripping voltammetry of the anticancer agent 5-fluorouracil and determination in urine. Talanta 44:305–310. doi:10.1016/S0039-9140(96)01957-1
Kish JA, Weaver A, Jacobs J, Cummings G, Al-Sarraf M (1984) Cisplatin and 5-fluorouracil infusion in patients with recurrent and disseminated epidermoid cancer of the head and neck. Cancer 53:1819–1824. doi:10.1002/1097-0142(19840501)53:9<1819:AID-CNCR2820530903>3.0.CO;2-R
Kovach JS, Moertel CG, Schutt AJ, Hahn R Gr, Reitmeier RJ (1974) A controlled study of combined 1,3-bis-(2-chloroethyl)-1-nitrosourea and 5-fluorouracil therapy for advanced gastric and pancreatic cancer. Cancer 33:563–5670. doi:10.1002/1097-0142(197402)33:2<563:AID-CNCR2820330235>3.0.CO;2-K
Kuchaříková K, Novotný L, Yosypchuk B, Fojta M (2004) Detecting DNA damage with a silver solid amalgam electrode. Electroanalysis 16:410–414. doi:10.1002/elan.200302874
Longley DB, Harkin DP, Johnston PG (2003) 5-Fluorouracil: mechanism of action and clinical strategies. Nat Rev Cancer 3:330–338. doi:10.1038/nrc1074
Mahnik SN, Rizovski B, Fuerhacker M, Mader RM (2004) Determination of 5-fluorouracil in hospital effluents. Anal Bioanal Chem 380:31–35. doi:10.1007/s00216-004-2727-6
Marunaka T, Umeno Y, Yoshida K, Nagamachi M, Minami Y, Fuji S (1980) High-pressure liquid chromatographic determination of ftorafur [1-(tetrahydro-2-furanyl)-5-fluorouracil] and GLC-mass spectrometric determination of 5-fluorouracil and uracil in biological materials after oral administration of uracil plus ftorafur. J Pharm Sci 69:1296–1300. doi:10.1002/jps.2600691117
Meropol NJ (1998) Oral fluoropyrimidines in the treatment of colorectal cancer. Eur J Cancer 34:1509–1513. doi:10.1016/S0959-8049(98)00226-3
Micoli G, Turci R, Arpellini M, Minoia C (2001) Determination of 5-fluorouracil in environmental samples by solid-phase extraction and high-performance liquid chromatography with ultraviolet detection. J Chromatogr B 750:25–32. doi:10.1016/S0378-4347(00)00377-7
Mirčeski V, Gulaboski R, Jordanoski B, Komorsky-Lovrić Š (2000) Square-wave voltammetry of 5-fluorouracil. J Electroanal Chem 490:37–47. doi:10.1016/S0022-0728(00)00203-5
Murad AM, Santiago FF, Ptroianu A, Rocha PRS, Rodrigues MAG, Rausch M (1993) Modified therapy with 5-fluorouracil, doxorubicin, and methotrexate in advanced gastric cancer. Cancer 72:37–41. doi:10.1002/1097-0142(19930701)72:1<37:AID-CNCR2820720109>3.0.CO;2-P
Nováková K, Navrátil T, Jaklová Dytrtová J, Chýlková J (2013a) The use of copper solid amalgam electrodes for determination of the pesticide thiram. J Solid State Electrochem 17:1517–1528. doi:10.1007/s10008-013-2035-1
Nováková K, Navrátil T, Jaklová Dytrtová J, Chýlková J (2013b) Application of copper solid amalgam electrode for determination of fungicide tebuconazole. Int J Electrochem Sci 8:1–16
Nováková K, Hrdlička V, Navrátil T, Vyskočil V, Barek J (2014) Determination of 5-nitroindazole using silver solid amalgam electrode. Monatshefte für Chemmie Chem Mon 146:761–769. doi:10.1007/s00706-014-1346-y
Ordieres AJM, Gutierrez MJG, Garcia AC, Blanco PT (1987) Cathodic stripping voltammetry of 5-fluorouracil. Analyst 112:243–246. doi:10.1039/AN9871200243
Paleček E, Jelen F, Hung MA (1981) Reaction of the purine and pyrimidine derivatives with the electrode mercury. Bioelectrochem Bioenerg 8:621–631. doi:10.1016/0302-4598(81)87005-5
Pattar VP, Nandibewoor ST (2015) Electroanalytical method for the determination of 5-fluorouracil using a reduced graphene oxide/chitosan modified sensor. RSC Adv 5:34292–34301. doi:10.1039/C5RA04396D
Prasad BB, Srivastava S, Tiwari K, Sharma PS (2009) Development of uracil and 5-fluorouracil sensors based on molecularly imprinted polymer-modified hanging mercury drop electrode. Sens Mater 21:291–306
Prasad BB, Kumar D, Madhuri R, Tiwari MP (2012) Nonhydrolytic sol–gel derived imprinted polymer–multiwalled carbon nanotubes composite fiber sensors for electrochemical sensing of uracil and 5-fluorouracil. Electrochim Acta 71:106–115. doi:10.1016/j.electacta.2012.03.110
Remaud G, Boisdron-Celle M, Morel A, Gamelin A (2005) Sensitive MS/MS–liquid chromatography assay for simultaneous determination of tegafur, 5-fluorouracil and 5-fluorodihydrouracil in plasma. J Chromatogr B 824:153–160. doi:10.1016/j.jchromb.2005.07.023
Satyanarayana M, Goud KY, Reddy KK, Gobi KV (2015) Biopolymer stabilized nanogold particles on carbon nanotube support as sensing platform for electrochemical detection of 5-fluorouracil in-vitro. Electrochim Acta 178:608–616. doi:10.1016/j.electacta.2015.08.036
Takimoto CH (2001) The clinical pharmacology of the oral fluoropyrimidines. Curr Probl Cancer 25:134–213. doi:10.1067/mcn.2001.116058
Tauxe-Wuersch A, De Alencastro LF, Grandjean D, Tarradellas J (2006) Trace determination of tamoxifen and 5-fluorouracil in hospital and urban wastewaters. Int J Environ Anal Chem 86:473–485. doi:10.1080/03067310500291502
Thomas G, Dembo A, Ackerman I, Franssen E, Balogh J, Fyles A, Levin W (1998) A randomized trial of standard versus partially hyperfractionated radiation with or without concurrent 5-fluorouracil in locally advanced cervical cancer. Gynecol Oncol 69:137–145. doi:10.1006/gyno.1998.4990
Wang J, Lin MS, Villa V (1987) Investigation of the adsorptive stripping voltammetric behaviour of the anticancer drugs chlorambucil and 5-fluorouracil. Analyst 112:247–251. doi:10.1039/AN9871200247
Yosypchuk B, Barek J (2009) Analytical applications of solid and paste amalgam electrodes. Crit Rev Anal Chem 39:189. doi:10.1080/10408340903011838
Yosypchuk B, Novotný L (2002a) Electrodes of nontoxic solid amalgams for electrochemical measurements. Electroanalysis 14:1733–1738. doi:10.1002/elan.200290018
Yosypchuk B, Novotný L (2002b) Cathodic stripping voltammetry of cysteine using silver and copper solid amalgam electrodes. Talanta 56:971–976. doi:10.1016/S0039-9140(01)00657-9
Yosypchuk B, Novotný L (2003) Copper solid amalgam electrodes. Electroanalysis 15:121–125. doi:10.1002/elan.200390012
Yosypchuk B, Šestáková I, Novotný L (2003) Voltammetric determination of phytochelatins using copper solid amalgam electrode. Talanta 59:1253–1258. doi:10.1016/S0039-9140(03)00023-7
Zeybek DK, Demir B, Zeybek B, Pekyardimci S (2015) A sensitive electrochemical DNA biosensor for antineoplastic drug 5-fluorouracil based on glassy carbon electrode modified with poly(bromocresol purple). Talanta 144:793–800. doi:10.1016/j.talanta.2015.06.077
Zhu L, Shen GJ, Ding SQ, Hua X (2012) Determination of 5-fluorouracil in 5-fluorouracil injection and human serum by HPLC. J Food Drug Anals 20:947–950. doi:10.6227/jfda.2012200425
Acknowledgements
This work was supported by The Ministry of Education, Youth and Sports of the Czech Republic (Project No. CZ.1.07/2.3.00/30.0021 “Strengthening of Research and Development Teams at the University of Pardubice”) and by the University of Pardubice (Project No. SGS_2016_002).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Šelešovská, R., Janíková, L., Štěpánková, M. et al. Copper solid amalgam electrode as a simple and sensitive tool for voltammetric determination of the antineoplastic drug 5-fluorouracil in pharmaceuticals. Chem. Pap. 71, 679–688 (2017). https://doi.org/10.1007/s11696-016-0091-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11696-016-0091-6