Skip to main content
Log in

Is Fixation During Gastric Banding Necessary? A Randomised Clinical Study

  • Clinical Report
  • Published:
Obesity Surgery Aims and scope Submit manuscript

Abstract

Anterior fixation via a gastro-gastric suture in laparoscopic adjustable gastric banding (LAGB) is commonly performed to prevent band-related complications. However, the necessity of this common technique has never been proven. Not fixing the band would be time sparing and would reduce adhesions on the stomach and probably make revisional surgery easier. This study was conceived as a 3-year randomised clinical trial to test the safety and efficacy of the non-fixation technique. From December 2006 to December 2007, 81 patients undergoing LAGB were randomly distributed into two groups: group A, with gastro-gastric sutures (n = 41) and group B, without gastro-gastric fixation (n = 40). The two groups were equivalent regarding initial body mass index (BMI), age and sex ratio. The main outcome was postoperative complications and secondary outcomes were operative time and weight loss expressed by the percentage of excess BMI loss (%EBMIL). All patients were prospectively followed up for 2 years. The mean preoperative BMI was 42.5 kg/m² (35–56). All patients were available for follow-up at 2 years. The mean overall preoperative time was 82 ± 20 min for the fixation group and 72 ± 20 min for the non-fixation group (p = 0.13). The mean hospital stay was 4.1 ± 1.5 days (no significant difference between the two groups). The 2-year %EBMIL was 35.9 for group A and 39.4 for group B (p = NS). The mean BMI at 2 years was 36.3 and 36.1, respectively, with no statistical difference. We observed three early band slippages in the non-fixation group and none in the fixation group. Three bands were removed during the second year of follow-up for causes other than band slippage (no significant difference between the two groups). This study was interrupted before a statistical significance could be reached, under the general agreement of all participating surgeons, because of the three unexpected early band slippages. For the patients who did not suffer from this complication, we did not observe any differences between the two groups in terms of late complications and weight loss. The operative time was shorter in the non-fixation group. This randomised clinical trial suggests that care should be taken when not fixating the LAGB because of the risk of early postoperative band slippage. We suggest that fixing the LAGB by gastro-gastric sutures should remain common practice.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Data from the National Register of ATIH (Agence Technique de L’Information pour l’Hospitalisation), http://www.atih.sante.fr/. Accessed 1 Apr 2011.

  2. O'Brien PE, Dixon JB, Laurie C, et al. A prospective randomized trial of placement of the laparoscopic adjustable gastric band: comparison of the perigastric and pars flaccida pathways. Obes Surg. 2005;15(6):820–6.

    Article  PubMed  Google Scholar 

  3. Khoursheed M, Al-Bader I, Mohammad AI, et al. Slippage after adjustable gastric banding according to the pars flaccida and the perigastric approach. Med Princ Pract. 2007;16(2):110–3.

    Article  PubMed  CAS  Google Scholar 

  4. Dargent J. Pouch dilatation and slippage after adjustable gastric banding: is it still an issue? Obes Surg. 2003;13:111–15.

    Article  PubMed  Google Scholar 

  5. Fielding GA, Duncombe JE. Clinical and radiological follow-up of laparoscopic adjustable gastric bands, 1998 and 2000: a comparison of two techniques. Obes Surg. 2005;15:634–40.

    Article  PubMed  Google Scholar 

  6. Weiner R, Blanco-Engert R, Weiner S, et al. Outcome after laparoscopic adjustable gastric banding—8 years’ experience. Obes Surg. 2003;13:427–34.

    Article  PubMed  CAS  Google Scholar 

  7. Wölnerhanssen B, Kern B, Peters T, et al. Reduction in slippage with 11-cm Lap-Band® and change of gastric banding technique. Obes Surg. 2005;15:1050–4.

    Article  PubMed  Google Scholar 

  8. Zappa MA, Micheletto G, Lattuada E, et al. Prevention of pouch dilatation after laparoscopic adjustable gastric banding. Obes Surg. 2006;16(2):132–6.

    Article  PubMed  Google Scholar 

  9. Singhal R, Kitchen M, Ndirika S, et al. The "Birmingham stitch"—avoiding slippage in laparoscopic gastric banding. Obes Surg. 2008;18(4):359–63.

    Article  PubMed  Google Scholar 

  10. Boschi S, Fogli L, Berta RD, et al. Avoiding complications after laparoscopic esophago-gastric banding: experience with 400 consecutive patients. Obes Surg. 2006;16(9):1166–70.

    Article  PubMed  Google Scholar 

  11. Shashidhar I, Gallagher K, Horner J. Does suturing prevents gastric band slippage?: a national (British) survey presented at the International Federation for the Surgery of Obesity and Metabolic Disorders, XIV World Congress, Palais des Congrès, Paris, France, August 26–29, 2009 (abstract). Obes Surg. 2009;19:953–1076.

    Article  Google Scholar 

  12. Lantsberg L, Cohen Y, Kirshtein B, et al. Laparoscopic adjustable gastric banding: with or without gastro-gastric sutures? Presented at the International Federation for the Surgery of Obesity and Metabolic Disorders, XIV World Congress, Palais des Congrès, Paris, France, August 26–29, 2009 (abstract). Obes Surg. 2009;19:953–1076.

    Article  Google Scholar 

  13. Lantsberg L, Yizhak A, Avinoah E, et al. Laparoscopic gastric banding in adolescents. Presented at the 4th International Alpine Obesity Surgery Expert Meeting, Saalfelden, Austria, March 12–15, 2006, (abstract). Obes Surg. 2006;16:217.

    Google Scholar 

  14. Avinoah E, Lantsberg L, Mizrahi S. Laparoscopic gastric banding for morbidly obese adolescents—ten years of clinical experience. Presented at the International Federation for the Surgery of Obesity and Metabolic Disorders, XIV World Congress, Palais des Congrès, Paris, France, August 26–29, 2009 (abstract). Obes Surg. 2009;19:953–1076.

    Article  Google Scholar 

  15. Boudouris O, Gaitis A, Koutsogoulas N. Is the fixation of gastric band useful? Presented at the International Federation for the Surgery of Obesity and Metabolic Disorders, XIV World Congress, Palais des Congrès, Paris, France, August 26–29, 2009 (abstract). Obes Surg. 2009;19:953–1076.

    Article  Google Scholar 

  16. Kasalický M, Fried M, Pesková M. Are complications of gastric banding decreased with cuff fixation? Sb Lek. 2002;103(2):213–22.

    PubMed  Google Scholar 

  17. Fried M, Dolezalova K, Sramkova P. Adjustable gastric banding outcomes with and without gastrogastric imbrication sutures: a randomized controlled trial. Surg Obes Relat Dis. 2011;7(1):23–31.

    Article  PubMed  Google Scholar 

  18. Thomas H, Agrawal S. Systematic review of same-day laparoscopic adjustable gastric band surgery. Obes Surg. 2011;21(6):805–10.

    Article  PubMed  Google Scholar 

  19. Msika S. Surgery for morbid obesity: 2. Complications. Results of a technologic evaluation by the ANAES. J Chir (Paris). 2003;140(1):4–21.

    CAS  Google Scholar 

Download references

Conflicts of Interest

The authors do not have any commercial interest to declare.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Lazzati.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lazzati, A., Polliand, C., Porta, M. et al. Is Fixation During Gastric Banding Necessary? A Randomised Clinical Study. OBES SURG 21, 1859–1863 (2011). https://doi.org/10.1007/s11695-011-0523-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11695-011-0523-x

Keywords

Navigation