Abstract
Managing the maintenance of CT scanners can often present a significant challenge for numerous companies. Nevertheless, this challenge can be effectively addressed using a variety of well-established tools grounded in optimal ergonomics. Hence, the primary objective of this study is to employ PARETO's maintenance management methodology in the analysis of component failures within a 16-slice scanner. To obtain failure data, service reports from three Neusoft NeuViz 16-slice scanners were collected over a two-year period. The components examined included the gantry, console, patient couch, and reprographic system. The cumulative failures totaled 53, with 20, 13, 11, and 9 failures recorded for the gantry, console, reprographic system, and patient couch, respectively. These corresponded to percentages of 37.73, 24.52, 20.75, and 16.98%. Notably, the gantry and console accounted for 80% of scanner failures. Furthermore, a detailed analysis of the gantry failures highlighted that a substantial portion of them, specifically 80%, could be attributed to the F102 fuse holder, UCOM card, DMS system, and the left-hand control panel. Similarly, in the case of console failures, the Database and RDC card were identified as culprits responsible for 80% of such failures. Consequently, to enhance the availability and reliability of the Neusoft NeuViz scanner, it is imperative to periodically implement a regimen of preventive, corrective, and improvement actions.
Similar content being viewed by others
References
M. El Mansouri, A. Choukri, S. Semghouli, M. Talbi, K. Eddaoui, Z. Saga, Size-specific dose estimates for thoracic and abdominal computed tomography examinations at two Moroccan hospitals. J. Digit. Imaging. 2022, 1–6 (2022)
M. El Mansouri, A. Choukri, M. Talbi, O.K. Hakam, Impact of tube voltage on radiation dose (CTDI) and image quality at chest CT examination. Atom Indones. 47(2), 105–109 (2021)
M. El Mansouri, A. Choukri, O. Nhila, M. Talbi, Evaluation of radiation dose in lumbar spine computed tomography in a single Moroccan center. Radiat. Phys. Chem. 195, 110089 (2022)
M. El Mansouri, A. Choukri, M. Talbi, H. Khallouki, Computed tomography scan optimization of chest and abdomen protocols. Mosc. Univ. Phys. Bull. 76(1), S88–S94 (2022)
R. Marini, C. Anam, E. Hidayanto, A. Naufal, G. Dougherty, Automated slice thickness measurement on the Nessoft CT QA Phantom. Int. J. Sci. Res. Sci. Technol. 10(3), 472–484 (2023)
O. Khaldouni et al., La gestion des dispositifs médicaux et l’état des lieux des services biomédicaux au Maroc. IRBM News. 42(4), 100337 (2021)
B.G. Mwanza, C. Mbohwa, An assessment of the effectiveness of equipment maintenance practices in public hospitals. Procedia Manuf. 4, 307–314 (2015)
A.F. Cardona Ortegón, W.J. Guerrero, Optimizing maintenance policies of computed tomography scanners with stochastic failures. Stud. Comput. Intell. 987, 331–342 (2021)
Maintenance - Préalables aux contrats de maintenance - Inventaires et expertise d’états de biens. https://www.boutique.afnor.org/fr-fr/norme/fd-x60100/maintenance-prealables-aux-contrats-de-maintenance-inventaires-et-expertise/fa141738/29207. Accessed 29-Jun-2023.
A. Jamshidi, S. A. Rahimi, D. Ait-Kadi, A. Ruiz, and A. Ruiz Bartolome, Medical devices inspection and maintenance; a literature review Prioritization of patients’ access to health care services View project supplying operating theatre View project Medical devices Inspection and Maintenance; A Literature Review (2014)
R. Dunford, Q. Su, E. Tamang, The Pareto principle. Plymouth Stud. Sci. 07(1), 140–148 (2014)
A. Grosfeld-Nir, B. Ronen, N. Kozlovsky, The Pareto managerial principle: when does it apply? Int. J. Prod. Res. 45(10), 2317–2325 (2007). https://doi.org/10.1080/00207540600818203
NeuViz 16 Classic CT - Neusoft Medical Systems. http://www.neusoftmedical.com/en_m/cpyjjfa/ct/NeuViz16Classic/. Accessed 29-Jun-2023.
What Is a Pareto Analysis?
G. Kohl, The evolution and state-of-the-art principles of multislice computed tomography. Proc. Am. Thorac. Soc. 2(6), 470–476 (2005)
M. Prokop, Multislice CT: technical principles and future trends. Eur. Radiol. 13(5), 3–13 (2003)
Neusoft NeuViz 16 System CT scanner - Preinstallation Manual. https://fr.scribd.com/document/397211709/4541-102-60551-NeuViz-16-System-Preinstallation-Manual-Rev-A. Accessed 30-Jun-2023
Acknowledgments
None.
Funding
No external funding was obtained for the execution of this study.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
There is no conflict of interest to be declared.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
El Mansouri, M., Talbi, M., Tahiri, Z. et al. Application of the Pareto Tool for the Analysis of CT Scanner Failures. J Fail. Anal. and Preven. 23, 2039–2043 (2023). https://doi.org/10.1007/s11668-023-01748-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11668-023-01748-y