Failure Analysis of Heat Exchanger Using Internal Rotary Inspection System (IRIS)

  • Technical Article---Peer-Reviewed
  • Published:
Journal of Failure Analysis and Prevention Aims and scope Submit manuscript

Abstract

Retubing of a heat exchanger always plays a critical role in oil and gas plants. Normally, many end-users prefer to do full retubing rather than partial retubing during maintenance or shutdown in order to achieve more efficiency. But in case of alloy steel tube-based heat exchanger, partial retubing is preferred because cost of alloy steel tubes is ten times higher than that of the carbon steel tubes. In this research, low-efficiency heat exchanger was selected since it requires full retubing (maintenance) due to severe in-service tube thickness loss and low efficiency as per end-user. Tube material was Inconel SB 163-800H, and the quantity of tubes was 286. Among numerous advanced NDT strategies used to minimize downtime arising from catastrophic failures induced by erosion/corrosion or mechanical loss sustained during the operating period, internal rotating inspection was chosen. This approach identifies a lack of wall thickness reduction arising from deterioration, wear, pitting (ID & OD) and corrosion. After IRIS inspection method was carried out, it was easy to categorize how many tubes are exactly defective and exchanger requires partial retubing or full retubing which finds huge savings and reduction in maintenance cost and time. IRIS inspection method also provides the distribution of tubes by wall thickness loss of total 286 tubes in the heat exchanger and retubing of heat exchanger will be further continued to achieve more efficiency.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. M.F. Saffiudeen, F.T. Mohammed, A. Syed, A case study on procedure standardization of heat exchanger retubing in KSA oil and gas industries. J Fail. Anal. Preven. 20, 1451–1455 (2020). https://doi.org/10.1007/s11668-020-00965-z.

    Article  Google Scholar 

  2. F.E. Al-Qadeeb, Tubing inspection using multiple NDT techniques, in 3rd MENDT—Middle East Nondestructive Testing Conference & Exhibition—27–30 Nov 2005 Bahrain, Manama

  3. Anmol Birring, Eddy Current Testing vs. Ultrasonic IRIS for Inspection of Heat Exchanger Tubing

  4. K.S. Vivekanand, K.S. Venkataraman, NDE Techniques for reliable inspection of carbon steel tubes, in Proceedings of the National Seminar on

  5. K. Krzywosz, L. Cagle, Flaw Detection and Characterization in Heat Exchanger Tubing. MTI Project 123, Material Technology Institute of the Chemical Industries, St. Louis (1999)

  6. M. Birchall, N. Sevciuc, C. Madureira, Internal Ultrasonic Pipe & Tube Inspection—IRIS

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohamed Fayas Saffiudeen.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Saffiudeen, M.F., Syed, A. & Mohammed, F.T. Failure Analysis of Heat Exchanger Using Internal Rotary Inspection System (IRIS). J Fail. Anal. and Preven. 21, 494–498 (2021). https://doi.org/10.1007/s11668-020-01093-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11668-020-01093-4

Keywords

Navigation