Abstract
Building failure usually results in collapse if not discovered and properly addressed. Building collapse/failure most times causes loss of properties and lives. A case study of a partially collapsed one-story building is presented for emphasis with technical assessment of the partial-collapse cause so as to proffer remedy of the structure. This is achieved through detailed engineering analysis of the building’s structural elements and identification of remedial options. Field inspection is carried out through soil excavation to assess the foundation condition, taking soil samples from the collapsed building for laboratory study and nondestructive test. From inspection, it was observed that the building construction was inadequately supervised and as a result was under-reinforced, which led to excessive cracks and deflection. The soil is classified by AASHTO A-2-4: maximum dry density 2.15 mg/m3 and optimum moisture content 9%. The compressive strength of the structural elements was measured using the rebound hammer, and a mean compressive strength of 13 N/mm2 was obtained which indicates a low-compressive-strength concrete. Analytical hierarchical process is utilized as the multi-criteria decision-making method to derive the actual partial-collapse cause; from the priority vector 6, 56, 26 and 12% were obtained for soil/foundation, under-reinforcement, low-compressive-strength and overloading alternatives, respectively. The consistency ratio computed was 0.065 which shows the decision maker’s subjective assessment was consistent. The summary of the failure investigation underscored the importance of ensuring proper supervision and quality control for framed-structures construction.
Similar content being viewed by others
Abbreviations
- PCM:
-
Pairwise comparison matrix
- AHP:
-
Analytical hierarchical process
- PV:
-
Priority vector
- RI:
-
Random Consistency Index
- CI:
-
Consistency Index
- CR:
-
Consistency ratio
- AASHTO:
-
American Association of State Highway and Transportation Officials
References
M.A. Salau, Design, construction and maintenance measure for preventing the collapse of reinforced concrete structure. J. Niger. Inst. Struct. Eng. I(1), 1–13 (2005)
T.U. Onyemachi, Z.A. Uji, Building failures and it’s implication on real estate investment in Nigeria. AARCHES J. 4(1), 57–63 (2005)
Mansur Hamma-adama, Obinna Iheukwumere, Tahar Kouider, Analysis of causes of building collapse: system thinking approach. Jordan J. Civil Eng. 14(2), 188–197 (2020)
M.A. Adetunji, O.I. Oyeleye, O.A. Akindele, Assessment of building collapse in Lagos Island. Nigeria. Am. J. Sustain. Cities Soc. 1(7), 18–28 (2018). https://doi.org/10.26808/rs.aj.i7v1.04
W. Ho, X. Xu, K.P. Dey, Multi-criteria decision making approaches for supplier evaluation and selection: a literature review. Eur. J. Oper. Res. 202, 16–24 (2010)
J.-Y. Do, D.-K. Kim, AHP-based evaluation model for optimal selection process of patching materials for concrete repair: focused on quantitative requirements. Int. J. Concrete Struct. Mater. 6(2), 87–100 (2012)
I.G. Chendo, N.I. Obi, Building collapse in Nigeria: the causes, effects, consequences and remedies. Int. J. Civil Eng. Construct. Estate Manage. 3(4), 41–49 (2015)
G.M. Ayininuola, O.O. Olalusi, Assessment of building failures in Nigeria: lagos and Ibadan as case study. Afr. J. Sci. Technol. 5(1), 73–78 (2004)
R. Olagunju, S. Aremu, J. Ogundele, Incessant collapse of buildings in Nigeria: an architect’s view. Civil Environ. Res. 3(4), 49–54 (2013)
T.L. Saaty, An exposition of the AHP in reply to the paper “Remarks on the analytic hierarchy process”. Manage. Sci. 36(3), 259–268 (1990)
T.L. Saaty, L.G. Vargas, Decision making with the analytic network process: economic, political, social and technological applications with benefits, opportunities, costs and risks (Springer, New York, 2006)
T.L. Saaty, L.G. Vargas, Models, methods, concepts and applications of the analytic hierarchy process (Kluwer Academic Publishers, Boston, 2000)
T.L. Saaty, Axiomatic foundation of the analytic hierarchy process. Manage. Sci. 32(7), 841–855 (1986)
T.L. Saaty, Decision-making with the AHP: why is the principal eigenvector necessary. Eur. J. Oper. Res. 145(1), 85–91 (2003)
C.O. Olayinka, S.O. Abiodun, O. Ayodeji, J. Opeyemi, O.B. Daniel, Incessant building collapse in Nigeria: a framework for post-development management control. Develop. Country Stud. 7(3), 114–127 (2017)
S.A. Oke, A.N. Amadi, A.E. Abalaka, R.T. Akerele, Result of subsoil investigation on a collapsed building site in Lagos. Nigerian J. Construct. Technol. Manage. 10(1&2), 36–45 (2009)
A.F. Bosede, G.M. Sunday, An investigation on the causes of building collapse in Nigeria. J. Environ. Sci. Resour. Manage. 6(1), 12–22 (2014)
A.M. Olajumoke, L.A. Oke, A.B. Fajobi, M.O. Ogedengbe, Engineering failure analysis of a failed building in Osun State, Nigeria. J. Failed Anal. Prevent. 9, 8–15 (2009)
K.C. Onyelowe, G. Alaneme, C. Igboayaka, F. Orji, H. Ugwuanyi, D. Van Bui, M. Van Nguyen, Scheffe optimization of swelling California bearing ratio, compressive strength, and durability potentials of quarry dust stabilized soft clay soil. Mater. Sci. Energy Technol. 2(1), 67–77 (2019). https://doi.org/10.1016/j.mset.2018.10.005
AASHTO (1995a) Determining the Liquid Limit of Soils. AASHTO Designation: T89-94, Standard Specifications for Transportation Materials and Methods of Sampling and Testing, American association of state highway and transportation officials, 17th Edition, Washington, DC
AASHTO (1995b) Determining the Plastic Limit and Plasticity Index of Soils. AASHTO Designation: T90-94, Standard Specifications for Transportation Materials and Methods of Sampling and Testing, American Association of State Highway and Transportation Officials, 17th Edition, Washington, DC
AASHTO (1993) Particle Size Analysis of Soils. AASHTO Designation: T88-93, Standard Specifications for Transportation Materials and Methods of Sampling and Testing, American Association of State Highway and Transportation Officials, 16th Edition, Washington, DC
AASHTO (1995c) The Moisture-Density Relations Using a 4.45-kg (10-lb) Rammer and a 457-mm (18-in.) Drop. AASHTO Designation: T180-93, Standard Specifications for Transportation Materials and Methods of Sampling and Testing, American Association of State Highway and Transportation Officials, 17th Edition, Washington, DC
M. Bernasconi, C. Choirat, R. Seri, Measurement by subjective estimation: testing for separable representations. J. Math. Psych. 52(3), 184–201 (2008)
Nucera, F. & Pucinotti, R. (2009). Destructive and Non-destructive Testing on Reinforced Concrete Structure: The Case Study of the Museum of Magna Graecia in Reggio, Calabria
BS 8110: Structural use of concrete, Part 3. British Standards Institution, London (1985)
BS 8110: Structural use of concrete, Part 1. British Standards Institution, London (1997)
BS 6399: Loading for buildings, Part 1 (Code of practice for dead and imposed loads). British Standards Institution, London (1996)
W.H. Moseley, J.H. Bungey, Reinforced Concrete Design, ELBS, 3rd edn. (Chapman and Hall, Hong Kong, 1990)
F.K. Kong, R.H. Evans, Reinforced and Prestressed Concrete, ELBS, 3rd edn. (Chapman and Hall, Hong Kong, 1990)
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
In this research study, there are no recorded conflicts of interests. We also affirm that the content of this work is original and has followed the journal template. Compliance with Ethical Standards was strictly observed.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Alaneme, G.U., Ezeokpube, G.C. & Mbadike, E.M. Failure Analysis of a Partially Collapsed Building using Analytical Hierarchical Process. J Fail. Anal. and Preven. 21, 160–171 (2021). https://doi.org/10.1007/s11668-020-01040-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11668-020-01040-3