Advertisement

Journal of Failure Analysis and Prevention

, Volume 16, Issue 4, pp 527–532 | Cite as

Lamellar Tearing: A Failure Case Study

  • Sujit S. Laddha
  • Pandurang S. Salunkhe
  • Deepashri D. Nage
Case History---Peer-Reviewed
  • 189 Downloads

Abstract

A variety of materials are used in the Oil & Gas industry ranging from carbon steel, stainless steel to nickel alloys, etc. including non-metallic materials as well. Amongst these, carbon steel is the industry favorite because of many of its desirable attributes like machinability, weldability, availability, and cost. Wide use of carbon steel in the industry is also due to the presence of required properties for the specific application. In spite of carbon steel’s wide uses, poor workmanship, improper heat treatment, or negligent manufacturing processes can reduce its service life and also can lead to unexpected failures. One such failure case involves carbon steel plate meant for construction of a tank that failed by cracking immediately after the welding operation. A detailed investigation was carried out by means of visual examination, metallographic and chemical analysis, SEM, and EDAX analysis. Microstructure revealed banded pearlitic structure along with a number of inclusions, a few of which were elongated. In conclusion, stresses due to weld joint restraint, elongated inclusions, and high transverse direction stresses after welding resulted in lamellar tearing which propagated in the linear direction along the weld line.

Keywords

Lamellar tearing Inclusions MnS Welding Cracking 

References

  1. 1.
    J.W. McEnerney, Assessment of Lamellar Tearing. ORNL/NUREG/TM-171 (US Nuclear Regulatory Commission, Rockville, 1978)Google Scholar
  2. 2.
    S. Ganesh, R.D. Stout, Material variables affecting lamellar tearing susceptibility in steels. Weld. J. (Miami) 55(11), 341-s–354-s (1976)Google Scholar
  3. 3.
    J.C.M. Farrar, R.E. Dolby, Lamellar Tearing in Welded Steel Fabrication—The Role of Sulphide Inclusions, Sulphide Inclusions in Steel (American Society for Metals, Materials Park, 1975), pp. 252–268Google Scholar
  4. 4.
    J.C.M. Farrar, Inclusions and susceptibility to lamellar tearing of welded structural steels. Weld. J. 8, 321-s–331-s (1974)Google Scholar
  5. 5.
    A.D. Wilson, Clean steel technology—fundamental to the development of high performance steels, in Advances in the Production and Use of Steel with Improved Internal Cleanliness. ASTM STP 1361, ed. by J.K. Mahaney Jr. (American Society for Testing and Materials, West Conshohocken, 1999), pp. 73–88Google Scholar
  6. 6.
    J. Somella, Significance and Control of Lamellar Tearing of Steel Plate in the Shipbuilding Industry. SSC-290 (Ship Structure Committee, Washington, DC, 1979)Google Scholar
  7. 7.
    Technical Sheet on Lamellar Tearing, European Federation for Welding Joining and Cutting, http://www.ewf.be/media/documentosdocs/doc_78_lamellar_tearing.pdf

Copyright information

© ASM International 2016

Authors and Affiliations

  • Sujit S. Laddha
    • 1
  • Pandurang S. Salunkhe
    • 1
  • Deepashri D. Nage
    • 1
  1. 1.Research & Development CentreL&T Hydrocarbon Engineering LtdMumbaiIndia