Abstract
Among degradable metal cardiac stent materials, zinc has great biocompatibility and corrosion properties, which make it become the most potential stent material. However, the mechanical properties of zinc cannot meet the performance requirements of stent material which severely limit its application. In this paper, Zn-xCu (x = 1, 2 and 3 wt.%) alloys were prepared, and their mechanical properties, corrosion properties and biocompatibility were studied. Tensile testing showed the tensile strength and hardness of Zn-xCu alloys both increased with the addition of copper, but the elongation decreased at first and then upturned. Since the formation of galvanic cell, the corrosion rates of Zn-xCu alloys increased. The main corrosion mechanism of Zn-xCu alloy was pitting corrosion, and the corrosion products mainly included ZnO and Zn(OH)2. The cytotoxicity evaluation showed that Cu2+ and Zn2+ would contribute to cell proliferation, while the concentrations of them reached a suitable range like the concentration of soaking solution of Zn-3Cu alloy was 25%. However, it would inhibit proliferation, while the concentrations of Zn2+ and Cu2+ were too large. In general, Zn-3Cu alloy had the best comprehensive properties.
This is a preview of subscription content, access via your institution.









References
E. Yılmaz, A. Gökçe, F. Findik, O. Gulsoy, and O. Iyibilgin, Mechanical Properties and Electrochemical Behavior of Porous Ti-Nb Biomaterials, J. Mech. Behav. Biomed. Mater., 2018, 87, p 59–67
E. Yılmaz, A. Gökçe, F. Findik, and O. Gulsoy, Assessment of Ti-16Nb-xZr Alloys Produced Via PIM for Implant Applications, J. Therm. Anal. Calorimet., 2018, 134(1), p 7–14
P.K. Bowen, J. Drelich, and J. Goldman, Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stent, Adv. Mater., 2013, 25(18), p 2577
H.F. Li, H.X. Xie, Y.F. Zheng, F.Y. Zhou, K.J. Qiu, X. Wang, S.H. Chen, L. Huang, L. Tian, and L. Qiu, Development of Biodegradable Zn-X Binary Alloys with Nutrient Alloying Elements Mg, Ca and Sr, Sci. Rep., 2015, 5, p 10719
X.W. Liu, Study on the Structure and Properties of Medical Degradable Zinc-Based Materials, Harbin Engineering University, Harbin, 2016
C. Shen, Study on Mechanical Properties, Degradation Properties and Biocompatibility of Medical Degradable Zinc Alloy (Zn-1.2 Mg-0.1Ca), Fourth Military Medical University, Xi’an, 2017
J. Ma, N. Zhou, and D. Zhu, Endothelial Cellular Responses to Biodegradable Metal Zinc, ACS Biomater. Sci. Eng., 2016, 2(4), p 634
E. Shearier, P.K. Bowen, W. He, A. Drelich, J. Drelich, J. Goldman, and F. Zhao, In vitro Cytotoxicity, Adhesion, and Proliferation of Human Vascular Cells Exposed to Zinc, ACS Biomater. Sci. Eng., 2016, 2(4), p 634
P.K. Bowen, R. Guillory, E.R. Shearier, J.M. Seitz, J. Drelich, M.L. Bocks, F. Zhao, and J. Goldman, Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents, Mater. Sci. Eng., C, 2015, 56, p 467
N.S. Murni, M.S. Dambatta, S.K. Yeap, G.R.A. Froemming, and H. Hermawan, Cytotoxicity Evaluation of Biodegradable Zn-3 Mg Alloy Toward Normal Human Osteoblast Cells, Mater. Sci. Eng., C, 2015, 49, p 560–566
M. Sikora-Jasinska, E. Mostaed, A. Mostaed et al., Fabrication, Mechanical Properties and in Vitro Degradation Behavior of Newly Developed ZnAg Alloys for Degradable Implant Applications, Mater. Sci. Eng., C, 2017, 77, p 1170–1181
J.S. Jing, T.M. Wang, R. Ling, and Y. Ke, The Beneficial Effects of Copper in the Cardiovascular System, Adv. Mod. Biomed., 2018, 18(16), p 3196–3200
Y. Ke and R. Ling, New Copper-Containing Metal Cardiovascular Scaffold Materials, Progress Chin. Mater., 2018, 37(09), p 681–692
Y. Ma. Research on Copper-based Solder Brazing Particle Reinforced Composite Coating, 2007
Z.B. Tang, J.L. Niu, H. Huang, H. Zhang, J. Pei, J. Pei, and G.Y. Yuan, Potential Biodegradable Zn-Cu Binary Alloys Developed for Cardiovascular Implant Applications, J. Mech. Behav. Biomed. Mater., 2017, 72, p 182–192
D. Gerlier and N. Thomasset, Use of MTT Colorimetric Assay to Measure Cell Activation, J. Immunol. Methods, 1986, 94(1–2), p 57–63
S. Zhang, X. Zhang, C. Zhao, J. Li, Y. Song, C. Xie, H. Tao, Y. Zhang, Y. He, Y. Jiang, and Y. Bian, Research on an Mg-Zn Alloy as a Degradable Biomaterial, Acta Biomater., 2010, 6, p 626–640
X. Zhang, G. Yuan, L. Mao, J. Niu, P. Fu, and W. Ding, Effects of Extrusion and Heat Treatment on the Mechanical Properties and Biocorrosion Behaviors of a Mg-Nd-Zn-Zr Alloy, Mech. Behav. Biomed. Mater., 2012, 7, p 77–86
S. Lin, Q. Wang, X. Yan et al., Mechanical Properties, Degradation Behaviors and Biocompatibility Evaluation of a Biodegradable Zn-Mg-Cu Alloy for Cardiovascular Implants, Mater. Lett., 2019, 234, p 294–297
J. Wang, F. Witte, T. Xi, Y. Zheng, K. Yang, Y. Yang, D. Zhao, J. Meng, Y. Li, W. Li, K. Chan, and L. Qin, Recommendation for Modifying Current Cytotoxicity Testing Standards for Biodegradable Magnesium-Based Materials, Acta Biomater., 2015, 21, p 237–249
Acknowledgments
The National Natural Science Foundation of China (Grant numbers #51401101) is acknowledged for funding this work. & represented these authors contributed equally to this work.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Jiajun Huang and Yonglai Lai are common first author.
Rights and permissions
About this article
Cite this article
Huang, J., Lai, Y., Jin, H. et al. Preparation and Properties of Zn-Cu Alloy for Potential Stent Material. J. of Materi Eng and Perform 29, 6484–6493 (2020). https://doi.org/10.1007/s11665-020-05167-0
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11665-020-05167-0
Keywords
- biocompatibility
- corrosion rate
- mechanical properties
- stent
- zinc-copper alloys