Abstract
A 10 MeV, 5 kW S-band travelling wave electron linear accelerator has been developed at Raja Ramanna Centre for Advanced Technology for industrial applications. The electron accelerating structure is made of oxygen-free electronic (OFE) copper and comprises of fifty-six brazed joints and is fabricated in multiple stages, as per the process and testing requirements. The accelerating structure is often required to be repaired through an additional brazing cycle with the same filler. The present study evaluates possible microstructural and mechanical property degradation of OFE copper brazed joints, as a result of its exposure to multiple brazing cycles. The study was performed on an OFE copper cavity stack brazed assembly, made through a four-stage brazing using BVAg-8 as braze filler. The resultant brazed assembly did not exhibit any leak at a sensitivity of 1 × 10−10 mbar.L/s. The results of the study demonstrate that OFE copper brazements can be safely subjected to an additional brazing cycle without causing significant degradation in its microstructure and strength. However, brazed joint’s exposure to any additional brazing cycles results in the formation of voids and cracks due to intergranular penetration of silver, with associated drop in tensile strength from about 210 MPa to about 150-180 MPa. Based on the results of study, it is recommended to qualify the accelerating structure, fabricated through multiple brazing cycles, by a suitable non-destructive technique. The results of the study are important for design, fabrication and maintenance of electron linear accelerator components.
Similar content being viewed by others
References
R.S Sandha, S.G. Goswami, R.S. Choudhary, J. Dwivedi, S. Sharma, T. Veerbhadraiah, S.D. Sharma, K. Yedle, V. Bhatnagar, P. Ram Sankar, P. Ganesh, R. Kaul, N. Kulkarni, V. Kumar, P. Jana, Y. Wanmode, S. Reddy, P. Shrivastava, R. Sridhar, G. Mundra and A.C. Thakurta, Engineering Design and Development of 10 MeV, S-Band Accelerating Structure, Paper ID 209, in Proceedings of Indian Particle Accelerator Conference InPAC-2015, Dec. 21-24, 2015, Tata Institute of Fundamental Research, Colaba, Mumbai, India, 2015
ASTM F68-10, Standard Specification For Oxygen-Free Copper In Wrought Forms For Electron DeviceS, ASTM International, West Conshohocken, 2010
E. Huttel, Materials for accelerator vacuum systems, http://www.chem.elte.hu/departments/altkem/vakuumtechnika/CERN19.pdf
S.B. Hodge, L.W. Funk and S.O. Schriber, Mechanical Design Considerations of a Standing Wave S-band Accelerator with On-Axis Couplers, in Proceedings of Proton Linear Accelerator Conference, Chalk River, Ontario, Canada, vol. F06, 1976, pp. 344–349
R. Singh, K Yedle and A.K. Jain, Development of Vacuum Brazing Furnace, in Proceedings of Indian Vacuum Society National Symposium on Vacuum Science and Technology and its Application to Plasmas, IVSNS-2005, Nov. 16-18, 2005, Gandhinagar, India
D.K. Wang, H.C. Wu, R.K. Shiue, and C. Chen, Vacuum repair brazing of the Inconel 939 superalloy, Adv. Mater. Res., 2008, 51, p 71–78. doi:10.4028/www.scientific.net/AMR.51.71
Y.H. Kim, I.H. Kim, and C.S. Kim, Effect of process variables on microstructure and mechanical properties of wide-gap brazed IN738 superalloy, Key Eng. Mater., 2005, 297–300, p 2876–2882. doi:10.4028/www.scientific.net/KEM.297-300.2876
Xiao Huang and Warren Miglietti, Wide gap braze repair of gas turbine blades and vanes—a review, J. Eng. Gas Turbines Power, 2012, 134(1), p 010801. doi:10.1115/1.4003962
D.P. Sekulić, Ed., Advances in brazing—science, technology and applications, Woodhead Publishing Limited, Cambridge, 2013
P.R. Subramanian and J.H. Perepezko, The Ag-Cu (silver-copper) system, J. Ph. Equilib., 1993, 14(1), p 62–75. doi:10.1007/BF02652162
L. Xin, Q. Wenqing, L. Haitao, and W. Guojian, Grain boundary penetration behavior analysis of OFC brazed with AgCu28 brazing filler, J. Beijing Univ. Aeronaut. Astronaut., 2014, 40, p 717–720. doi:10.13700/j.bh.1001-5965.2013.0379
http://alphaassembly.com/~/media/Files/CooksonElectronics/Effect%20of%20Multiple%20Reflow%20Cycles%20on%20Solder%20Joint%20Formation%20and%20Reliability%20SMTAI%20Oct%202010.pdf visited on 22-May-2017
Acknowledgments
Authors thank Shri A. P. Singh, Shri C. Manikandan and Shri G. S. Deshmukh for their contribution in chemical cleaning and Shri Ram Nihal Ram for metallographic specimen preparation. They thank staff of accelerator components design and fabrication section for conducting brazing experiments and colleagues involved in helium leak testing of brazed cavity. Authors thankfully acknowledge Dr. N. Sathish and Shri Anup Kumar Khare of Advanced Materials and Processes Research Institute (AMPRI), Bhopal, for their support in SEM-EDS analysis.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ganesh, P., Sandha, R.S., Choudhary, R.S. et al. Influence of Exposure to Multiple Brazing Cycles on the Integrity of OFE Copper Brazed Joints. J. of Materi Eng and Perform 26, 5348–5354 (2017). https://doi.org/10.1007/s11665-017-2991-1
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11665-017-2991-1