Skip to main content
Log in

Experimental observation of two phase flow of R123 inside a herringbone microfin tube

  • Published:
Journal of Thermal Science Aims and scope Submit manuscript

Abstract

Vapor-liquid two phase flow behavior of R123 inside herringbone microfin tubes has been studied. Herringbone microfin tube is a kind of internally finned tube in which microfins are installed inside the tube where the microfins form multi-V-shape in flow direction. For the present experiment three different types of herringbone microfin tubes with helix angle β=8°, 14° and 28° are used. Experimental observations showed how flow diverges and converges inside herringbone microfin tube due to fin arrangement. The effect is more remarkable for larger helix angle. From the measurements of the cross-sectional liquid flow rate distribution, the liquid removal and collection and the entrained droplet are discussed. Quantity of liquid droplets is increased with increase of helix angle. The tube with helix angle β=28° shows higher quantity of liquid droplets than others.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ebisu, T, Fujino, H, Torikoshi, K. Heat Transfer Characteristics and Heat Exchanger Performances for R407C Using Herringbone Heat Transfer Tube. Proc. International Refrigerant Conference at Purdue. 1998. 343–348

  2. Miyara, A, Nonaka, K, Taniguchi, M. Condensation Heat Transfer and Flow Pattern Inside a Herringbone-type Microfin Tube. International Journal of Refrigeration, 2000, 23: 141–152

    Article  Google Scholar 

  3. Miyara, A, Otsubo, Y, Ohtsuka, S. Evaporation Heat Transfer of R410 in Herringbone Microfin Tubes. Conf. IIR Commission B1 2001/5, Thermophysical Properties and Transfer Process of New Refrigerant. Paderborn, Germany, 2001. 314–319

  4. Yoshimura, H, Mori, H, Yoshida, S, et al. Measurement of Flow Rate of Entrained Liquid Droplets in Microfin Tubes. Proc. 38th National Heat Transfer Symposium of Japan (in Japanese). Saitama, Japan, 200. 2: 647

  5. Kakimoto, Y, Mori, H, Yoshida, S, et al. Observation of Air-water Two-phase Flow Behavior in Microfin Tubes. 38th National Heat Transfer Symposium of Japan (in Japanese). Saitama, Japan, 2001. 2: 645

    Google Scholar 

  6. McLinder, M O, Klein, S A, Lemmon, E W, et al. NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP. Version 6.0.1, 1998

  7. Miyara, A, Otsubo, Y. Condensation Heat Transfer of Herringbone Microfin Tubes. Int. J. Thermal Sciences, 2002, 41: 639–645

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miyara, A., Islam, M.A., Mizuta, Y. et al. Experimental observation of two phase flow of R123 inside a herringbone microfin tube. J. of Therm. Sci. 12, 270–274 (2003). https://doi.org/10.1007/s11630-003-0081-1

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11630-003-0081-1

Keyword

Navigation