Abstract
In this paper the effects of the condenser design parameters (such as turbine inlet condition, turbine power and condenser pressure) on heat transfer area, cooling water flow-rate, condenser cost and specific energy generation cost are studied for surface type condenser. The results are given in the text and also shown as diagrams.
Similar content being viewed by others
References
Eyice, S. Steam Turbines. Turkey: Yildiz Technical University, 1976. III
Schröder, K. GrosseDampfkraftwerke. Springer Verlag, 1970
Coulson, Richardson. Chemical Engineering Fluid Flow. Heat Transfer and Mass Transfer, 1996, 5
Aybers, N, Sahin, B. Energy Cost. Turkey: Yildiz Technical University, 1995
Geankoplis, Christie, J. Transport Processes and Unit Operation. Prentice Hall, 1993
Guyer, E C. Handbook of Applied Thermal Design. McGraw Hill Book, 1989
Perry, P H, Green, D. Chemical Engineering Handbook. Mc-Graw Hill Book, 1997
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bekdemir, Ş., Öztürk, R. & Yumurtac, Z. Condenser optimization in steam power plant. J. of Therm. Sci. 12, 176–178 (2003). https://doi.org/10.1007/s11630-003-0062-4