Abstract
A body in an advanced stage of mummification was found in a concrete apartment in Japan. Natural complete mummification is very rare in Japan’s humid and temperate climate. We performed multi-slice computed tomography (MSCT) to obtain information on the body prior to autopsy. MSCT clearly illustrated old fractures in the right lower leg. Bone resists destruction during body decomposition. If antemortem medical records of the deceased are available, MSCT scanning can provide information for positive identification. At autopsy, the cervical tissues presented as a dried mass, and it was difficult to separately remove the hyoid bone and thyroid cartilage. Fractures of the large horn of the hyoid bone and superior horn of the thyroid cartilage, which are not observed in all strangulation cases, strongly suggest criminal activity. The diagnosis of these fractures is of great value. In our case, MSCT revealed that there was no fracture in the hyoid bone or ossified area of the thyroid cartilage. Hard tissues are usually well preserved in mummies. Although MSCT images have limits in mummies because of the severe dryness of soft tissues and organs, they could become a useful tool not only for personal identification, but also for the identification of neck compression.
References
Lynnerup N. Mummies. Am J Phys Anthropol. 2007;Suppl 45:162–90.
Harwood-Nash DC. Computed tomography of ancient Egyptian mummies. J Comput Assist Tomogr. 1979;3:768–73.
Jackowski C, Bolliger S, Thali MJ. Common and unexpected findings in mummies from ancient Egypt and South America as revealed by CT. Radiographics. 2008;28:1477–92.
Sakuma A, Ishii M, Yamamoto S, Shimofusa R, Kobayashi K, Motani H, et al. Application of postmortem 3D-CT facial reconstruction for personal identification. J Forensic Sci. 2010;55:1624–9.
Eklektos N, Dayal MR, Manger PR. A forensic case study of a naturally mummified brain from the bushveld of South Africa. J Forensic Sci. 2006;51:498–503.
Oh CS, Lee SY, Lee IS, Kim YS, Koh KS, Shin DH. Differential findings in post-factum dissections of medieval Korean mummies exhibiting similar preservation patterns on computerized tomography images. Ann Anat. 2011;193:544–9.
Persson A, Jackowski C, Engström E, Zachrisson H. Advances of dual source, dual-energy imaging in postmortem CT. Eur J Radiol. 2008;68:446–55.
Wanek J, Székely G, Rühli F. X-ray absorption-based imaging and its limitations in the differentiation of ancient mummified tissue. Skelet Radiol. 2011;40:595–601.
Murphy WA Jr, Nedden Dz D, Gostner P, Knapp R, Recheis W, Seidler H. The iceman: discovery and imaging. Radiology. 2003;226:614–29.
Kempter M, Ross S, Spendlove D, Flach PM, Preiss U, Thali MJ, et al. Post-mortem imaging of laryngohyoid fractures in strangulation incidents: first results. Leg Med (Tokyo). 2009;11:267–71.
Conflict of interest
The authors declare that they have no conflicts of interest.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Usui, A., Kawasumi, Y., Hosokai, Y. et al. Radiological analysis of a naturally mummified body. Jpn J Radiol 30, 458–462 (2012). https://doi.org/10.1007/s11604-012-0068-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11604-012-0068-5