Effect of respirator resistance on tolerant capacity during graded load exercise

Summary

Respirator breathing resistance impacts performance of wearers during constant work load. However, it is less clear as to how breathing resistance affects the tolerant capacity of users during graded work load. The present study investigated the tolerant capacity of 8 individuals during incremental work load. The 8 subjects were required to wear two matched respirators (respirators I and II which were designed to have different breathing resistances and the same dead space) respectively on separate days and then work to end points. Minute ventilation (VE), breathing frequency (BF), oxygen consumption (VO2) and heart rate (HR) were recorded during exercise, while tolerant time, response time and breathing discomfort were measured at the end of each test trial. The test variables were compared between the two respirators by using matched-pairs t-test. The results showed that the tolerant time was significantly reduced for the respirator I with higher level of breathing resistance when compared with its counterpart with lower breathing resistance (respirator II) (P<0.05). The same changes occurred for response time. Results also showed a significant increase in VE and BF for respirator I wearers when the work load was above 125 W. The O2 consumption was similar under the two breathing resistance conditions. These findings suggested that the respiratory resistance caused by self-contained breathing apparatus (SCBA) has an impact on the tolerant capacity of users.

This is a preview of subscription content, access via your institution.

References

  1. Johnson AT, Scott WH, Lausted CG, et al. Effect of respirator inspiratory resistance level on constant load treadmill work performance. Am Ind Hyg Assoc J, 1999, 60(4):474–479

    PubMed  Article  CAS  Google Scholar 

  2. Caretti DM, Scott WH, Johnson AT, et al. Work performance when breathing through different respirator exhalation resistances. Am Ind Hyg Assoc J, 2001,62(4): 411–415

    Article  CAS  Google Scholar 

  3. Peter BR, Ann TD, Thomas OD. The physiological consequences of wearing industrial respirators: A review. Am Ind Hyg Assoc J, 1979,40(6):517–534

    Article  Google Scholar 

  4. Duggan A. Energy cost of stepping protective clothing ensembles. Ergonomics, 1988,31(1):3–11

    PubMed  Article  CAS  Google Scholar 

  5. Seliga R, Bhattacharya A, Succop P, et al. Effect of work load and respirator wear on postural stability, heart rate, and perceived exertion. Am Ind Hyg Assoc J, 1991,52(10):417–422

    PubMed  Article  CAS  Google Scholar 

  6. William EN, Joe S, Fredric LG, et al. Physiological responses during graded treadmill exercise in chemical-resistant personal protective equipment. Preh Emer Care, 2007,11(4):394–396

    Article  Google Scholar 

  7. Arthur TJ, Cathryn RD, Charles OD. Respirator mask effects on exercise metabolic measures. Am Ind Hyg Assoc J, 1995,56(5):467–473

    Article  Google Scholar 

  8. Louhevaara V, Smolander J, Korhoen O, et al. Effects of industrial respirators on breathing pattern at different work levels. Eur J Appl Physiol, 1986,55(2):142–146

    Article  CAS  Google Scholar 

  9. Caretti DM, Coyne KM, Johnson A, et al. Performance when breathing through different respirator inhalation and exhalation resistances during hard work. J Occup Env Hyg, 2006,3(4):214–224

    Article  Google Scholar 

  10. Jette M, Thoden J, Livingstone S. Physiological effects of inspiratory resistance on progressive aerobic work. Eur J Appl Physiol,1990,60(1):65–70

    Article  CAS  Google Scholar 

  11. Laferty AE, Mckay RT. Physiologic effects and measurement of carbon dioxide and oxygen levels during qualitative respirator fit testing. J Chem Health Safety, 2006,13(5):22–28

    Article  Google Scholar 

  12. Catetti DM, Whitley JA. Exercise performance during inspiratory resistance breathing under exhaustive constant load work. Ergonomics, 1998,41(4):501–511

    Article  Google Scholar 

  13. Berndtsson G. Peak inhalation air flow and minute volumes measured in a bicycle ergometer test. J Int Soc Respir Prot, 2004,21(5):21–29

    Google Scholar 

  14. Johnson AT, Dooly CR, Coyne KM, et al. Work performance when breathing through very high exhalation resistance. J Int Soc Respir Prot, 1997,15(2):25–29

    Google Scholar 

  15. Johnson AT, Weiss R, Grove C. Respirator performance rating tables for mask design. Am Ind Hyg Assoc J, 1992,53(3):193–202

    PubMed  Article  CAS  Google Scholar 

  16. Harber P, Tamimie J, Emory J, et al. Effects of exercise using industrial respirators. Am Ind Hyg Assoc J, 1984,45(9):603–609

    PubMed  Article  CAS  Google Scholar 

  17. Harber P, Tamimie JM, Bhattacharya A, et al. Physiologic effect of respirator dead space and resisitance loading. J Occu Med, 1982,24(9):681–684

    Article  CAS  Google Scholar 

  18. Johnson AT, Scott WH, Lausted CG, et al. Effect of external dead volume on performance while wearing a respirator. Am Ind Hyg Assoc J, 2000,61(5):678–684

    Article  CAS  Google Scholar 

  19. Louhevaara V, Toumi T, Korhonen O, et al. Cardiorespiratory effects of respiratory protective devices during exercise in well-trained men. Eur J Appl Physiol, 1984,52(3):340–345

    Article  CAS  Google Scholar 

  20. Yan S, Jason HT. Breathing responses to small inspiratory threshold loads in humans. J Appl Physiol, 1999,86(3): 874–880

    PubMed  CAS  Google Scholar 

  21. Morgan WP. Psychological problems associated with the wearing of industrial respirators: A review. Am Ind Hyg Assoc J, 1983,44(9):671–676

    PubMed  Article  CAS  Google Scholar 

  22. Qiu M, Liu BL, Liu ZQ. Effect of SCBA on wearer. CPPE (Chinese), 2008, 89(4):19–22

    Google Scholar 

  23. DuBois AB, Harb ZF, Fox SH. Thermal discomfort of respiratory protective devices. Am Ind Hyg Assoc J, 1990, 51(10):550–554

    PubMed  Article  CAS  Google Scholar 

  24. Jones JG. The physiological cost of wearing a disposable respirator. Am Ind Hyg Assoc J, 1991,52(6):219–225

    PubMed  Article  CAS  Google Scholar 

  25. Caretti DM. Cognitive performance and mood during respirator wear and exercise. Am Ind Hyg Assoc J, 1999,60(2):213–218

    PubMed  Article  CAS  Google Scholar 

  26. Zimmerman NJ, Eberts C, Salvendy G, et al. Effects of respirators on performance of physical, psychomotor and cognitive tasks. Ergonomics, 1991,34(3):321–334

    PubMed  Article  CAS  Google Scholar 

  27. Laird IS, Goldsmith R, Pack RJ, et al. The effect on heart rate and facial skin temperature of wearing respiratory protection at work. Annual Occu Hyg, 2002,46(2):143–148

    Article  CAS  Google Scholar 

  28. Johnson AT, Dooly CR, Dotson CO. Respirator mask effects on exercise metabolic measure. Am Ind Hyg Assoc J, 1995,56(5):467–473

    PubMed  Article  CAS  Google Scholar 

  29. Johnson AT, Dooly CR, Blanchard CA, et al. Influence of anxiety level on work performance with and without a respirator mask. Am Ind Hyg Assoc J, 1995,56(9):858–865

    PubMed  Article  CAS  Google Scholar 

  30. Qiu M, Wang S, Liu TM. Analysis on the problems of protective respirators based on ergonomics. China Safety Sci J, 2007,17(2):139–143

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sheng Wang.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Qiu, M., Wang, S. Effect of respirator resistance on tolerant capacity during graded load exercise. J. Huazhong Univ. Sci. Technol. [Med. Sci.] 32, 434–437 (2012). https://doi.org/10.1007/s11596-012-0075-x

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11596-012-0075-x

Keywords

  • self-contained breathing apparatus
  • breathing resistance
  • respirator
  • tolerant time