Abstract
The biocompatibility of silicone rubber (SR) based electrodes coating with poly (vinyl alcohol) (PVA) films after implanted in the brain of rats was investigated. Twenty-two Wistar rats were used and implanted with SR electrodes and PVA/PAA films coated electrodes in left and right cerebral cortex respectively. After 4 and 8 weeks, the expression of glial fibrillary acidic protein (GFAP, a specific marker of astrocytes) and cluster of differentiation 68 (CD68, a specific marker of macrophages) were evaluated by immunohistochemistry. After 8 weeks, GFAP and CD68 expressions around PVA electrodes were significantly lower than those around SR electrodes in every stratified area (0–50 μm, 50–100 μm, 100 μm from further up to the electrode-tissue interface). The results show that PVA coating can reduce the expressions of GFAP and CD68, suggesting the PVA coating can improve the biocompatibility of the SR while it is implanted in brain.
Similar content being viewed by others
References
Chen D, Fertig S J, Kleitman N, et al. Advances in Neural Interfaces: Report from the 2006 NIH Neural Interfaces Workshop[J]. J Neural Eng. 2007, 4(3): S137–S142
Piper M, Abrams G M, Marks W J Jr. Deep Brain Stimulation for the Treatment of Parkinson’s Disease: Overview and Impact on Gait and Mobility[J]. Neuro Rehabilitation, 2005, 20(3): 223–232
Back C, Alesch F, Lanmüller H. Postoperative Monitoring of the Electrical Properties of Tissue and Electrodes in Deep brain Stimulation[J]. Neuromodulation, 2003, 6(4): 248–253
He W, McConnell G C, Schneider T M, et al. A Novel Anti-inflammatory Surface for Neural Electrodes[J]. Adv Mater, 2007, 19(21): 3 529–3 533
Polikov V S, Tresco P A, Reichert W M. Response of Brain Tissue to Chronically Implanted Neural Electrodes[J]. J Neurosci Methods, 2005, 148(1): 1–18
Yue YM, XU K, Liu XG, et al. Preparation and Characterization of Interpenetration Polymer Network Films Based on Poly(vinyl alcohol) and Poly(acrylic acid) for Drug Delivery[J]. J Appl Polym Sci, 2008, 108(6): 3836–3842.
Lee KY, Mooney DJ. Hydrogels for Tissue Engineering[J]. Chemical Reviews, 2001, 101(7): 1 869–1 879
Zhong Y, Bellamkonda RV. Biomaterials for the Central Nervous System[J]. J R Soc Interface, 2008, 5(26): 957–975
Fournier E, Passirani C, Montero-Menei C N, et al. Biocompatibility of Implantable Synthetic Polymeric Drug Carriers: Focus on Brain Biocompatibility[J]. Biomaterials, 2003, 24(19): 3 311–3 331
Biran R, Martin DC, Tresco PA. Neuronal Cell Loss Accompanies the Brain Tissue Response to Chronically Implanted Silicon Microelectrode Arrays[J]. Exp Neurol, 2005, 195(1): 115–126
McCall M A, Gregg R G, Behringer R R, et al. Targeted Deletion in Astrocyte Intermediate Filament (Gfap) Alters Neuronal Physiology[J]. Proc Natl Acad Sci U S A, 1996, 93(13): 6 361–6 366
Iwata M, Harada K, Hiramatsu K, et al. Fas Ligand Expressing Mononuclear Cells around Intrahepatic Bile Ducts Co-express CD68 in Primary Biliary Cirrhosis [J]. Liver, 2000, 20(2): 129–135
Author information
Authors and Affiliations
Corresponding author
Additional information
Funded by the “863” Program of China (No.2006AA02Z4E6) and the National Nature Science Foundation of China (No.30570516)
Rights and permissions
About this article
Cite this article
Zhou, Q., Li, T., Li, C. et al. Biocompatibility of implantable electrodes coated with PVA films in the brain of rats: a histological evaluation. J. Wuhan Univ. Technol.-Mat. Sci. Edit. 24, 393–396 (2009). https://doi.org/10.1007/s11595-009-3393-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11595-009-3393-5