Skip to main content
Log in

A multi-FPGA architecture-based real-time TFM ultrasound imaging

  • Original Research Paper
  • Published:
Journal of Real-Time Image Processing Aims and scope Submit manuscript

Abstract

Real-time imaging, using ultrasound techniques, is a complex task in non-destructive evaluation. In this context, fast and precise control systems require design of specialized parallel architectures. Total focusing method (TFM) for ultrasound imaging has many advantages in terms of flexibility and accuracy in comparison to traditional imaging techniques. However, one major drawback is the high number of data acquisitions and computing requirements for this imaging technique. Due to those constraints, the TFM algorithm was earlier classified in the field of post-processing tasks. This paper describes a multi-FPGA architecture for real-time TFM imaging using the full matrix capture (FMC). In the acquisition process, data are acquired using a phased array and processed with synthetic focusing techniques such as the TFM algorithm. The FMC-TFM architecture consists of a set of interconnected FPGAs integrated on an embedded system. Initially, this imaging system was dedicated to data acquisition using a phased array. The algorithm was reviewed and partitioned to parallelize processing tasks on FPGAs. The architecture was entirely described using VHDL language, synthesized and implemented on a V5FX70T Xilinx FPGA for the control and high-level processing tasks and four V5SX95T Xilinx FPGAs for the acquisition and low-level processing tasks. The designed architecture performs real-time FMC-TFM imaging with a good characterization of defects.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18

Similar content being viewed by others

References

  1. Von Ramm, O.T., Smith, S.W.: Beam steering with linear arrays. IEEE Trans Biomed Eng 30(8), 438–452 (1983)

    Article  Google Scholar 

  2. Harput, S., Bozkurt, A.: Ultrasonic phased array device for acoustic imaging in air. IEEE Sens J 8(11), 1755–1762 (2008)

    Article  Google Scholar 

  3. Luo, Y., Lu, X., Wang, K., Wang, L.: The application in detection of defects in compound material with ultrasonic phased array technology. In: Proceeding of the 26th Chinese control and decision conference (CCDC), pp. 2100–2103, May 31–June 2, 2014

  4. Hosono, Y., Yamashita, Y.: Piezoelectric ceramics with high dielectric constants for ultrasonic medical transducers. IEEE Trans Ultrason Ferroelectr Freq Contr 52(10), 1823–1828 (2005)

    Article  Google Scholar 

  5. Drinkwater, B.W., Wilcox, P.D.: Ultrasonic arrays for non-destructive evaluation: a review. NDT E Int. 39(7), 525–541 (2006)

    Article  Google Scholar 

  6. Li, Y., Robinson, B.: The cross algorithm for phase-aberration correction in medical ultrasound images formed with two-dimensional arrays. IEEE Trans Ultrason Ferroelectr Freq Control 55(3), 588–601 (2008)

    Article  Google Scholar 

  7. De Andrade Maia, O.M., Schneider, F.K., Maia, J.M., Comar Neves, L., Do Rocio Chiarello Penteado, S.: Wood characterization using the power spectral density and phase velocity of ultrasonic signals. In: Proceeding of IEEE international ultrasonics symposium (IUS), pp. 1416–1419, 3–6 Sept. 2014

  8. Yang, J.S., Zhao, X.G., Zhang, Y.J., Cao, Z.: A new type of wheeled intelligent ultrasonic thickness measurement system. In: Symposium on piezoelectricity, acoustic waves and device applications (SPAWDA), pp. 1–4, 25–27 Oct. 2013

  9. Lines, D.I.A., Pettigrew, I.G., Kirk, K.J., Cochran, S., Skramstad, J.A.: Rapid distributed data collection and processing with arrays—the next step beyond full waveform capture. In: The 44th annual British conference on NDT, vol. 48, no. 2, pp. 84–88. September 2005

  10. Jensen, J.A., Nikolov, S.I., Gammelmark, K.L., Pedersen, M.H.: Synthetic aperture ultrasound imaging. Ultrasonics 44, e5–e15 (2006)

    Article  Google Scholar 

  11. Nikolov, S.I., Jensen, J.A., Tomov, B.G.: Fast parametric beamformer for synthetic aperture imaging. IEEE Trans Ultrason Ferroelectr Freq Control 55(8), 1755–1767 (2008)

    Article  Google Scholar 

  12. Holmes, C., Drinkwater, B.W., Wilcox, P.D.: Post-processing of the full matrix of ultrasonic transmit–receive array data for non-destructive evaluation. NDT E Int. 38(8), 701–711 (2005)

    Article  Google Scholar 

  13. Holmes, C., Drinkwater, B.W., Wilcox, P.D.: Advanced post-processing for scanned ultrasonic arrays: application to defect detection and classification in non-destructive evaluation. Ultrasonics 48, 636–642 (2005)

    Article  Google Scholar 

  14. Jensen, J.A., Hansen, M., Tomov, B.G., Nokolov, S.I., Holten-Lund, H.: System architecture of an experimental synthetic aperture real-time ultrasound system. IEEE ultrasonics symposium, pp. 636–640 (2007)

  15. Lines, D., Wharrie, J., Hottenroth, J., Skramstad, J., Goodman, R., Wood, N.: Real-time ultrasonic array imaging using full matrix capture and the total focusing method. In: Proceedings of 2nd aircraft airworthiness and sustainment conference, San Diego, 18–21 April 2011

  16. Lambert, J., Pedron, A., Gens, G., Bimbard, F., Lacassagne, L., Iakovleva, E.: Performance evaluation of total focusing method on GPP and GPU. In: Conference on design and architectures for signal and image processing (DASIP), pp. 1–8, 23–25 Oct 2012

  17. Sutcliffe, M., Weston, M., Dutton, B., Charlton, P., Donne, K.: Real-time full matrix capture for ultrasonic non-destructive testing with acceleration of post-processing through graphic hardware. NDT E Int. 51, 16–23 (2012)

    Article  Google Scholar 

  18. Charlton, P., Sutcliffe, M., Weston, M., Cooper, I., Donne, K.: Full matrix capture with time efficient auto focusing of unknown geometry through dual-layered media. Insight (Br. J. NDT), 55(6) (2013)

  19. CIVA. Simulation software for non destructive testing. http://www-civa.cea.fr/

  20. MultiX++: PAUT equipment for NDT application. http://www.m2m-ndt.com/products/MultiXpp.pdf

  21. Virtex-5 FPGA RocketIO GTP transceiver wizard. http://www.xilinx.com/products/intellectual-property/v5_fpga_gtp_transceiver_wizard.html#documentation

  22. Todorovich, E., Dai Pra, A.L., Passoni, L.I., Vázquez, M., Cozzolino, E., Ferrara, F., Bioul, B.: Real-time speckle image processing. J Real Time Image Proc. (2013). doi:10.1007/s11554-013-0343-4

    Google Scholar 

  23. Bahri, N., Grandpierre, T., Masmoudi, N., Akil, M., Sorel, Y.: Optimization of real time application on mixed architecture using AAA methodology extension. Int J Electr Commun Comput Eng 4(5), 1455–1466 (2013)

    Google Scholar 

  24. Czechowski, K., Vuduc, R.: A theoretical framework for algorithm-architecture co-design. In: IEEE 27th international symposium on parallel and distributed processing (IPDPS), pp. 791–802, 20–24 May 2013. doi:10.1109/IPDPS.2013.99

  25. Njiki M., Elouardi, A., Bouaziz, S., Casula, O., Roy, O.: A real-time implementation of the total focusing method for rapid and precise diagnostic in non destructive evaluation. IEEE 24th international conference on application-specific systems, architectures and processors (ASAP), 2013

  26. Bannouf, S., Robert, S., Casula, O., Prada, C.: Data set reduction for ultrasonic TFM imaging using the effective aperture approach and virtual sources. J Phys Conf Ser 457(1), 0120071 (2013)

    Google Scholar 

  27. Cruza, J.F., Perez, M., Moreno, J.M., Fritsch, C.: Real time fast ultrasound imaging technology and possible applications. Phys Proc 63, 79–84 (2015)

    Article  Google Scholar 

Download references

Acknowledgments

This work has been supported by the French institute “Laboratoire d’Intégration de Systèmes et des Technologies” (LIST) from the “Commissariat à l’Energie Atomique” (CEA) in partnership with the M2M-NDT company.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Mickael Njiki or Abdelhafid Elouardi.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Njiki, M., Elouardi, A., Bouaziz, S. et al. A multi-FPGA architecture-based real-time TFM ultrasound imaging. J Real-Time Image Proc 16, 505–521 (2019). https://doi.org/10.1007/s11554-016-0563-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11554-016-0563-5

Keywords

Navigation