Abstract
Purpose
During ultrasound-guided (US-guided) needle puncture for minimally invasive procedures, automated needle tip localization can help clinicians capture small tips in US images easily and precisely, providing them with obvious tip indicators on the screen and bringing them more confidence during the procedures. However, automated needle tip localization in US images is challenging due to serious interferences arising from all kinds of echoes.
Methods
We propose a method that localizes needle tips under continuous spatial and temporal constraints in the real-time US frame stream. A temporal constraint is firstly acquired by detecting translational tip motion in motion-enhanced US images with a deep learning-based (DL-based) detector. A spatial constraint and candidate tip locations are obtained by detecting needle shafts and tips in the raw grayscale B-mode images with another DL-based detector. To provide continuous constraints, estimated tip velocity from acquired temporal constraint is used to predict tip locations in frames where no temporal or spatial constraint is detected. Finally, tip coordinates are precisely localized among candidate tips under the spatial and temporal constraints.
Results
Experimental results evaluated on 1121 US images from porcine organ punctures, and 895 images from human thyroid punctures demonstrate that the proposed method is effective and efficient, surpassing existing methods. On porcine organ data, a 97.2% recall rate and a 91.9% precision rate on tip detection and 0.88 ± 0.70 mm root-mean-square error (RMSE) on tip localization were achieved. On the human thyroid data, which was not involved in the training, 86.5% recall, 84.3% precision and 0.92 ± 0.78 mm RMSE were achieved separately. The running speed of 14.5 frames per second was achieved only using a CPU.
Conclusion
The proposed method provides a more reliable solution for automated needle tip localization during US-guided needle puncture, being more robust to interferences. Fast running speed leads to its practicability in the real-time US stream.
Similar content being viewed by others
References
Holm HH, Skjoldbye B (1996) Interventional ultrasound. Ultrasound Med Biol 22:773–789. https://doi.org/10.1016/0301-5629(96)00086-5
Karmakar MK, Li X, Ho AMH, Kwok WH, Chui PT (2009) Real-time ultrasound-guided paramedian epidural access: evaluation of a novel in-plane technique. Brit J Anaesthesia 102:845–854. https://doi.org/10.1093/bja/aep079
Conroy PH, Luyet C, McCartney CJ, McHardy PG (2013) Realtime ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach. Anesthesiol Res Pract. https://doi.org/10.1155/2013/525818
Lin TL, Chung CT, Lan HHC, Sheen HM (2014) Ultrasound guided facet joint injection to treat a spinal cyst. J Chin Med Assoc 77:213–216. https://doi.org/10.1016/j.jcma.2014.01.003
Gadsden J, Latmore M, Levine DM (2015) Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures. Expert Rev Med Dev 12:251–261. https://doi.org/10.1586/17434440.2015.995095
Stolka PJ, Foroughi P, Rendina M, Weiss CR, Hager GD, Boctor EM (2014) Needle guidance using handheld stereo vision and projection for ultrasound-based interventions. In: Proceedings of international conference on medical image computing and computer-assisted intervention (MICCAI), pp 684–691. https://doi.org/10.1007/978-3-319-10470-6_85
Zhao Y, Cachard C, Liebgott H (2013) Automatic needle detection and tracking in 3-D ultrasound using an ROI-based RANSAC and Kalman method. Ultrason Imag 35:283–306. https://doi.org/10.1177/0161734613502004
Hacihaliloglu I, Beigi P, Ng G, Rohling R, Salcudean S, Abolmaesumi P (2015) Projection-based phase features for localization of a needle tip in 2D curvilinear ultrasound. In: Proceedings of international conference on medical image computing and computer-assisted intervention (MICCAI), pp 347–354. https://doi.org/10.1007/978-3-319-24553-9_43
Mwikirize C, Nosher JL, Hacihaliloglu I (2018) Convolution neural networks for real-time needle detection and localization in 2D ultrasound. Int J Comput Assist Radiol Surg 13:647–657. https://doi.org/10.1007/s11548-018-1721-y
Harmat A, Rohling RN, Salcudean SE (2006) Needle tip localization using stylet vibration. Ultrasound Med Biol 32:1339–1348. https://doi.org/10.1016/j.ultrasmedbio.2006.05.019
Ayvali E, Desai J (2015) Optical flow-based tracking of needles and needle-tip localization using circular hough transform in ultrasound images. Ann Biomed Eng 43:1828–1840. https://doi.org/10.1007/s10439-014-1208-0
Mwikirize C, Nosher JL, Hacihaliloglu I (2019) Learning needle tip localization from digital subtraction in 2D ultrasound. Int J Comput Assist Radiol Surg 14:1017–1026. https://doi.org/10.1007/s11548-019-01951-z
Mwikirize C, Nosher JL, Hacihaliloglu I (2019) Single shot needle tip localization in 2D ultrasound. In: Proceedings of international conference on medical image computing and computer-assisted intervention (MICCAI), Shenzhen, China, p 637–645. https://doi.org/10.1007/978-3-030-32254-0_71
Mwikirize C, Kimbowa AB, Imanirakiza S, Katumba A, Nosher JL, Hacihaliloglu I (2021) Time-aware deep neural networks for needle tip localization in 2D ultrasound. Int J Comput Assist Radiol Surg 16:819–827. https://doi.org/10.1007/s11548-021-02361-w
Ge Z, Liu S, Wang F, Li Z, Sun J (2021) YOLOX: Exceeding YOLO series in 2021. arXiv preprint arXiv:2107.08430
Li H, Chen YL, Chang TH, Wu XY, Ou YS, Xu YS (2011) Binocular vision positioning for robot grasping. In: Proceedings, 2011 IEEE international conference on robotics and biomimetics (ROBIO), Karon Beach, Thailand, pp 1522–1527. https://doi.org/10.1109/ROBIO.2011.6181505
Loshchilov I, Hutter F (2016) SGDR: Stochastic gradient descent with warm restarts. arXiv preprint arXiv:1608.03983. https://doi.org/10.48550/arXiv.1608.03983
Acknowledgements
This work is supported in part by the National Natural Science Foundation of China (Grant Nos. 61832005, U21B2016).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethics approval
Ethical approval was waived by the local Ethics Committee of Hohai University in view of the retrospective nature of the study and all the procedures being performed were part of the routine care.
Informed consent
It is not necessary to obtain consent for the ultrasound images used in this research.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Wang, R., Tan, G. & Liu, X. Robust tip localization under continuous spatial and temporal constraints during 2D ultrasound-guided needle puncture. Int J CARS 18, 2233–2242 (2023). https://doi.org/10.1007/s11548-023-02894-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11548-023-02894-2