Cuenca-Navalon E, Finocchiaro T, Laumen M, Fritschi A, Schmitz-Rode T, Steinseifer U (2014) Design and evaluation of a hybrid mock circulatory loop for total artificial heart testing. Int J Artif Organs 1(37):71–80. https://doi.org/10.5301/ijao.5000301
Article
Google Scholar
Demondion P, Fournel L, Niculescu M, Pavie A, Leprince P (2013) The challenge of home discharge with a total artificial heart: the La PitieSalpetriere experience. Eur J Cardiothorac Surg 44(5):843–848. https://doi.org/10.1093/ejcts/ezt146
Article
PubMed
Google Scholar
Eurotransplant International Foundation (2016) Eurotransplant Statistics - 2015. Eurotransplant International Foundation. Leiden, Netherlands. Available via DIALOG: http://www.eurotransplant.org/cms/mediaobject.php?file=AR_ET_20153.pdf. Accessed 20 Dec 2016
Finocchiaro T, Butschen T, Kwant P, Steinseifer U, Schmitz-Rode T, Hameyer K, Lessmann M (2008) New linear motor concepts for artificial hearts. IEEE Trans Magn 44(6):678–681. https://doi.org/10.1109/TMAG.2007.916110
Article
Google Scholar
Fritschi A, Laumen M, Spiliopoulos S, Finocchiaro T, Egger C, Schmitz-Rode T, Tenderich G, Koerfer R, Steinseifer U (2013) Image based evaluation of mediastinal constraints for the development of a pulsatile total artificial heart. Biomed Eng Online 12(1):12. https://doi.org/10.1186/1475-925X-12-81
Article
Google Scholar
Gerosa G, Scuri S, Iop L, Torregrossa G (2014) Present and future perspectives on total artificial hearts. Ann Cardiothorac Surg 3(6):595–602. https://doi.org/10.3978/j.issn.2225-319X.2014.09.05
PubMed
PubMed Central
Article
Google Scholar
Guo J, Ge H, Ye J, Emadi A (2015) Improved method for MOSFET voltage rise-time and fall-time estimation in inverter switching loss calculation. Transportation Electrification Conference and Expo, Dearborn. https://doi.org/10.1109/ITEC.2015.7165790
Book
Google Scholar
Ohm D, Oleksuk R (2002) Influence of PWM schemes and commutation methods for DC and brushless motors and drives. P.E. Technology Conference, Rosemont
Google Scholar
Pelletier B, Blaszczyk Y, Carstens P, Alvarez G, Lamping F, Laumen M, Finocchiaro T, Steinseifer U (2016) Novel optical position sensing for miniaturized applications and validation in a total artificial heart. IEEE Trans Biomed Eng 63(3):478–484. https://doi.org/10.1109/TBME.2015.2463729
Article
PubMed
Google Scholar
Pelletier B, Spiliopoulos S, Finocchiaro T, Graef F, Kuipers K, Laumen M, Guersoy D, Steinseifer U, Koerfer R, Tenderich G (2014) System overview of the fully implantable destination therapy—ReinHeart-total artificial heart. Eur J Cardiothorac Surg 47(1):80–86. https://doi.org/10.1093/ejcts/ezu321
Article
PubMed
Google Scholar
Rashid M (2011) Inverters in power electronics handbook, 3rd edn. Elsevier, Amsterdam, pp 363–364
Google Scholar
Unthan K, Gräf F, Laumen M, Finocchiaro T, Sommer C, Lanmüller H, Steinseifer U (2015) Design and evaluation of a fully implantable control unit for blood pumps. BioMed Res Int 2015:9 pages. doi: https://doi.org/10.1155/2015/257848. Available: https://www.hindawi.com/journals/bmri/2015/257848/abs/
World Health Organization (2014) The top 10 causes of death. World Health Organization, Geneva, Switzerland. Available via DIALOG: http://www.who.int/mediacentre/factsheets/fs310/en/. Accessed 20 Dec 2016