The use of electromedical equipment (EME) throughout the years has brought benefits in the aid of diagnosis and therapies as well as in surgical interventions. However, the equipment may fail and can cause health hazards, for example, the passing of a small but dangerous electric current through the patient (microshock). To prevent and minimize the risk of failure we propose the Protegemed2, an extension of the previous version called Protegemed, addressed in 2009. This system uses radio frequency identification to automatically identify EME and increases the performance of the system allowing a large-scale supervision of EMEs. Protegemed2 was built embedded into the gas and electric power panel of surgical rooms and uses an ARM 32-bit microcontroller.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Amaral LA, Hessel FP, Bezerra EA, Corrêa JC, Longhi OB (2010) Dias TFO eCloudRFID A mobile software framework architecture for pervasive RFID-based applications. J Netw Comput Appl 34(3):972–979

    Google Scholar 

  2. Angeles R (2005) RFID technology: supply-chain applications and implementations issues. Inf Syst Manage 22(1):51–65

    Article  Google Scholar 

  3. Boncinelli S, Citti P, Del Re E, Campatelli G, Pierucci L, Bocchi L (2010) Real time detection and tracking of gauzes by RFID UWB technique. In: Proceedings of IEEE International Conference on RFID, Orlando, pp 97–101

  4. Chen PJ, Chen YF, Chai SK, Huang YF (2009) Implementation of an RFID-based management system for operation room. In: Proceedings of International Conference on Machine Learning and Cybernetics, 2009, Baoding, pp 2933–2938

  5. Cormen TH, Leiserson CE, Rivest RL (2001) Introduction To Algorithms, 2nd edn, The Mit Press, Cambridge, c2001

  6. ECRI (1992) OR Renovation and the use of isolated power and explosion-proof plugs. Health Devices 21(9):334–335

    Google Scholar 

  7. Ferris LP, King BG, Spence PW, Williams HB (1936) Effect of electric shock on the heart. AIEE Trans 55:498−515

    Google Scholar 

  8. Florentino GHP, Bezerra HU, de A Junior HB, Araújo MX, de M Valentim RA, Morais AHF, Jesus TO, Guerreiro AMG, Brandão GB, Paz de Araújo CA (2008) Hospital Automation RFID-Based. In: IEEE International Conference on Industrial Informatics, 2008. INDIN 2008. 6th Daejeon, pp 1534–1538

  9. Friedlander GD (1971) Electricity in hospital: elimination of lethal hazards IEEE spectrum 8(9):40–51

  10. IEC (2002) Electrical Installations of Buildings—Requirements for Special Installations or Locations—Medical Locations, Part 710.413.1.5, IT System, Geneva, Switzerland, IEC 60364-7-710 Ed. 1.0 b

  11. IEC (2005) Effects of Current on Human Beings and Livestock—Part 1:General Aspects, Geneva, Switzerland, IEC/TS 60479-1 Ed. 4.0 Std

  12. IEC (2005) Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance, Geneva, Switzerland, IEC 60601-1 Std

  13. Kuo F, Fu C, Liu L, Jin M (2007) The implementation of RFID in Emergency Medicine. In: IEEE International Conference on e-Health Networking, Application and Services, pp 125–130

  14. Lee S, Liang WH, Fang Q (2010) A low-power RFID integrated circuits for intelligent healthcare systems. IEEE Trans Inf Tech Biomed 14(6):1387–1396

    Article  Google Scholar 

  15. NXP HITAG (2012) Nxp Semiconductors. http://www.nxp.com/products/identification_and_security/smart_label_and_tag_ics/hitag/ Acessed 23 mar. 2012

  16. Panescu D (2006) Healthcare applications of rfid identification. Engineering in Medicine and biology magazine IEEE Comp Soc 25(3):77–83

    Google Scholar 

  17. Spalding LES, Abatti PJ, Ianiski A (2004) Controle automatic patrimonial e de segurança elétrica para equipamento s eletromédicos, Automatic Control Patrimonial and of Electric Safety for Electromedical Equipments, vol 1745, Brazilian Invention Patent 9701995-0 (04/22/1997)RPI/INPI, Rio de Janeiro, Brazil (in Portuguese)

  18. Spalding LES, Carpes WP Jr, Batistela NJ (2009) A method to detect the microshock risk during a surgical procedure. IEEE Trans Instr Meas 58(7):2335–2342

    Article  Google Scholar 

  19. Yamashita K et al (2008) Identification of information surgical instrument by ceramic RFID tag. In: Automation Congress, Hawaii, pp 1–6

Download references

Acknowledgments

The authors would like to thank the Brazilian research programs Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), Financiadora de Estudos e Projetos (FINEP) and Fundção de Amparo à Pesquisa do Estado do Rio Grande do Sul (Fapergs). They either would like to thank the São Vicente de Paulo Hospital in Passo Fundo-RS, Universidade de Passo Fundo (UPF) and Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS), sponsors of the project.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marcelo Trindade Rebonatto.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rebonatto, M.T., Spalding, L.E.S., Hessel, F.P. et al. Protegemed2: an extended platform based on RFID to identify EME and improve the detection of microshocks. Med Biol Eng Comput 51, 719–727 (2013). https://doi.org/10.1007/s11517-013-1041-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-013-1041-x

Keywords

Navigation