Skip to main content
Log in

High-resolution esophageal long-term ECG allows detailed atrial wave morphology analysis in case of atrial ectopic beats

  • Letter
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beats.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. ADuC7060 Data Sheet (2011) Analog Devices, Norwood, USA (Rev. C)

  2. Benzadón MN, Ortega DF, Thierer JM, Torcivia RAS, Aldunate L, Alves de Lima AE, Navia D, Dorsa A, Rossi A, Trivi M (2006) Comparison of the amplitude of the P-wave from intracardiac electrocardiogram obtained by means of a central venous catheter filled with saline solution to that obtained via esophageal electrocardiogram. Am J Cardiol 98:978–981

    Article  PubMed  Google Scholar 

  3. DiCarlo LA, Lin D, Jenkins JM (1993) Automated interpretation of cardiac arrhythmias: design and evaluation of a computerized model. J Electrocardiol 26:53–67

    Article  PubMed  CAS  Google Scholar 

  4. Farshchi S, Pesterev A, Nuyujukian PH, Mody I, Judy JW (2007) Bi-Fi: an embedded sensor/system architecture for remote biological monitoring. IEEE T Inf Technol B 11:611–618

    Article  Google Scholar 

  5. Goldwasser D, Bayés de Luna A, Serra G, Elosúa R, Rodriguez E, Guerra JM, Alonso C, Viñolas Prat X (2011) A new method of filtering T waves to detect hidden P waves in electrocardiogram signals. Europace 13:1028–1033

  6. Hickey B, Heneghan C (2002) Screening for paroxysmal atrial fibrillation using atrial premature contractions and spectral measures. In: Computers in cardiology. IEEE, pp 217–220

  7. Jenkins J, Wu D, Arzbaecher R (1979) Computer diagnosis of supraventricular and ventricular arrhythmias. A new esophageal technique. Circulation 60:977–987

    Article  PubMed  CAS  Google Scholar 

  8. Kligfield P, Gettes LS, Bailey JJ, Childers R, Deal BJ, Hancock EW, van Herpen G, Kors JA, Macfarlane P, Mirvis DM, Pahlm O, Rautaharju P, Wagner GS (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society Endorsed by the International Society for Computerized Electrocardiology. J Am Coll Cardiol 49:1109–1127

    Article  PubMed  Google Scholar 

  9. Márquez MF, Colín L, Guevara M, Iturralde P, Hermosillo AG (2002) Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring. Am Heart J 144:187–197

    PubMed  Google Scholar 

  10. Seet RCS, Friedman PA, Rabinstein AA (2011) Prolonged rhythm monitoring for the detection of occult paroxysmal atrial fibrillation in ischemic stroke of unknown cause. Circulation 124:477–486

    Article  PubMed  Google Scholar 

  11. Wallmann D, Tüller D, Wustmann K, Meier P, Isenegger J, Arnold M, Mattle HP, Delacrétaz E (2007) Frequent atrial premature beats predict paroxysmal atrial fibrillation in stroke patients. Stroke 38:2292–2294

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

This work was funded by the Commission for Technology and Innovation CTI, Switzerland, the Department of Cardiology, Bern University Hospital and the Swiss Heart Foundation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rolf Vogel.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Niederhauser, T., Marisa, T., Haeberlin, A. et al. High-resolution esophageal long-term ECG allows detailed atrial wave morphology analysis in case of atrial ectopic beats. Med Biol Eng Comput 50, 769–772 (2012). https://doi.org/10.1007/s11517-012-0915-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-012-0915-7

Keywords

Navigation