Asymmetric time-dependent model for the dynamic finger arterial pressure–volume relationship

  • Technical Note
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The volumetric pulses in the finger PPG signal appear as an information source for several indirect measurement methods. In this study we modelled transformation of pressure pulses into volume pulses in a wide transmural pressure range. The noninvasive finger arterial pressure and photoplethysmographic (PPG) signals were simultaneously registered in 13 healthy subjects while the pressure in the PPG cuff ramped up and down. The nonlinearity of the pressure–volume (PV) relationship was modelled by an asymmetric function, consisting of two arctangents, each for a different pressure region. The time dependency was described by the first order lag. The disturbing effect of slow creeps in the PPG signal was suppressed by an equal filtering of the measured and model-predicted signal. The differences between the two estimates of the subject’s PV relationship for the increasing and decreasing cuff pressure were small thus showing the repeatability of this method, which can be used for the characterization of individual finger arterial behaviour as well as its changes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  1. Allen J, Murray A (1999) Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniques. Physiol Meas 20(3):287–301

    Article  Google Scholar 

  2. Baker PD, Westenskow DR, Kück K (1997) Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure. Med Biol Eng Comput 35(3):271–278

    Article  Google Scholar 

  3. Bank AJ, Wang H, Holte JE et al (1996) Contribution of collagen, elastin, and smooth muscle to in vivo human brachial artery wall stress and elastic modulus. Circulation 94(12):3263–3270

    Google Scholar 

  4. Bank AJ, Kaiser DR, Rajala S et al (1999) In vivo human brachial artery elastic mechanics: effects of smooth muscle relaxation. Circulation 100(1):41–47

    Google Scholar 

  5. Buchs A, Slovik Y, Rapoport M et al (2005) Right–left correlation of the sympathetically induced fluctuations of the photoplethysmographic signal in diabetic and non-diabetic subjects. Med Biol Eng Comput 43:252–257

    Article  Google Scholar 

  6. Drzewiecki G, Hood R, Apple H (1994) Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann Biomed Eng 22(1):88–96

    Article  Google Scholar 

  7. Giannattasio C, Failla M, Grappiolo A et al (2001) Progression of large artery structural and functional alterations in type I diabetes. Diabetologia 44(2):203–208

    Article  Google Scholar 

  8. Gizdulich P, Wesseling KH (1988) Forearm arterial pressure-volume relationships in man. Clin Phys Physiol Meas 9(3):123–132

    Article  Google Scholar 

  9. Guerrisi M, Vannucci I, Gizdulich P (2002) Dynamic blood pressure–volume relationship estimated in man, in vivo. IFMBE Proc 2:47–48

    Google Scholar 

  10. Heerman JR, Segers P, Roosens CD et al (2005) Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters model. Am J Physiol Heart Circ Physiol] 288(5):H2504–H2511

    Article  Google Scholar 

  11. Imholz BP, Langewouters GJ, van Montfrans GA et al (1993) Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording. Hypertension 21(1):65–73

    Google Scholar 

  12. Lal SK, Mihailidou AS, Cejnar M et al (1993) Continuous, non-invasive volume-clamp blood pressure: determinants of performance. J Hypertens 11(12):1413–1422

    Article  Google Scholar 

  13. Langewouters GJ, Wesseling KH, Goedhard WJ (1984) The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17(6):425–435

    Article  Google Scholar 

  14. Mendelson Y (1992) Pulse oximetry: theory and applications for noninvasive monitoring (eng; includes abstract). Clin Chem 38(9):1601–1607

    Google Scholar 

  15. Millasseau SC, Guigui FG, Kelly RP et al (2000) Noninvasive assessment of the digital volume pulse. Comparison with the peripheral pressure pulse. Hypertension 36(6):952–956

    Google Scholar 

  16. Nitzan M, Khanokh B, Slovik Y (2002) The difference in pulse transit time to the toe and finger measured by photoplethysmography. Physiol Meas 23(1):85–93

    Article  Google Scholar 

  17. Pasipoularides A, Shu M, Shah A et al (2002) Right ventricular diastolic function in canine models of pressure overload, volume overload, and ischemia. Am J Physiol Heart Circ Physiol 283(5):H2140–H2150

    Google Scholar 

  18. Peñaz J (1973) Photoelectric measurement of blood pressure volume and flow in the finger. In: Digest of the international conference on medicine and biological engineering, August 13–17, Dresden, 104

  19. Peñaz J, Honzikova N, Jurak P (1997) Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries. Med Biol Eng Comput 35(6):633–637

    Article  Google Scholar 

  20. Raamat R, Talts J, Jagomägi K et al (1999) Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion. Med Biol Eng Comput 37(6):784–788

    Article  Google Scholar 

  21. Shelley KH, Murray WB, Chang D (1997) Arterial-pulse oximetry loops: a new method of monitoring vascular tone. J Clin Monit 13(4):223–228

    Article  Google Scholar 

  22. Tanaka G, Sawada Y, Matsumura K et al (2002) Finger arterial compliance as determined by transmission of light during mental stress and reactive hyperaemia. Eur J Appl Physiol 87(6):562–567

    Article  Google Scholar 

  23. Wesseling KH, de Wit B, van der Hoeven GMA et al (1995) Physiocal, calibrating finger vascular physiology for Finapres. Homeostasis 36:67–82

    Google Scholar 

Download references

Acknowledgment

This work was supported by Grant 6487 from the Estonian Science Foundation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jaak Talts.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Talts, J., Raamat, R. & Jagomägi, K. Asymmetric time-dependent model for the dynamic finger arterial pressure–volume relationship. Med Bio Eng Comput 44, 829–834 (2006). https://doi.org/10.1007/s11517-006-0090-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-006-0090-9

Keywords

Navigation