Skip to main content
Log in

Plasmonic Biosensor for Low-Index Liquid Analyte Detection Using Graphene-Assisted Photonic Crystal Fiber

  • Published:
Plasmonics Aims and scope Submit manuscript

Abstract

We report a sensitive D-shaped photonic crystal fiber-based surface plasmon resonance (PCF-SPR) sensor with linear sensing performance and a broad detection range for low refractive index (RI) liquid analytes ranging from 1.27 to 1.37 with possible extension beyond this range. We examine three combinations of materials (silver only, graphite on silver, and graphene on silver) as plasmonic nanofilm for the PCF-SPR and demonstrate that graphene-assisted PCF has the best overall performance. We show that graphene coating of silver nanofilm improves the sensitivity and the overall figure of merit of the sensor, besides the practical benefit of protecting the silver nanofilm from surface oxidation. Furthermore, we propose two distinct ways of analyte sensing based on filling patterns where the liquid analyte can be filled internally into the top two air holes of the PCF, or externally into a rectangle channel at the top of the fiber. In the internal filling detection scheme, the graphene-assisted PCF-SPR sensor demonstrates ultra-linearity, a detection range of 0.1 refractive index unit (RIU) between 1.27 and 1.37, an average linear spectral sensitivity of 2320 nm/RIU, and a maximum amplitude sensitivity of 192 RIU−1 for 1150 nm excitation. In the external filling detection scheme, the PCF-SPR exhibits extremely large sensitivities with a maximum spectral sensitivity of 22,400 nm/RIU close to analyte RI of 1.33, and a maximum figure of merit (FOM) of 127 which is approximately five times larger than that of the similar reported PCF-SPR sensors in the literature. The combination of a broad detection range for low-index analytes, large sensitivities, design flexibility, and stability against surface oxidation renders our proposed sensor as an interesting candidate for biosensing applications in chemistry, biology, and medicine.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Stockman MI (2011) Nanoplasmonics: past, present, and glimpse into future. Opt Express 19:22029–22106

    Article  Google Scholar 

  2. Allsop R, Neal R (2019) A review: evolution and diversity of optical fibre plasmonic sensors. Sensors 19(22):4874

    Article  Google Scholar 

  3. Monfared YE (2020) Refractive index sensor based on surface plasmon resonance excitation in a D-shaped photonic crystal fiber coated by titanium nitride. Plasmonics 15:535–542

    Article  Google Scholar 

  4. Monfared Y E, Hajati M, Liang C, Yang S, Qasymeh M, Quasi-D-shaped fiber optic plasmonic biosensor for high-index analyte detection. IEEE Sensors (2019), in press.

  5. Choi SH, Kim YL, Byun KM (2011) Graphene-on-silver substrates for sensitive surface plasmon resonance imaging biosensors. Opt Express 19:458–466

    Article  CAS  Google Scholar 

  6. Dash JN, Jha R (2014) Graphene-based birefringent photonic crystal fiber sensor using surface plasmon resonance. IEEE Photon Tech Lett 26(11):1092–1095

    Article  CAS  Google Scholar 

  7. Johnson PB, Christy RW (1972) Optical constants of the noble metals. Phys Rev B 6:4370–4379

    Article  CAS  Google Scholar 

  8. He S, Zhang X, He Y (2013) Graphene nano-ribbon waveguides of record-small mode area and ultra-high effective refractive indices for future VLSI. Opt Express 21:30664–30673

    Article  Google Scholar 

  9. Qasymeh M, Eleuch H (2019) Quantum microwave-to-optical conversion in electrically driven multilayer graphene. Opt Express 27:5945–5960

    Article  CAS  Google Scholar 

  10. Taft E, Philipp H (1965) Optical properties of graphite. Phys Rev 138:A197-202

    Article  Google Scholar 

  11. Santos DF, Guerreiro A, Baptista JM (2017) SPR optimization using metamaterials in a D-type PCF refractive index sensor. Opt Fiber Technol 33:83–88

    Article  CAS  Google Scholar 

  12. Yang X, Lu Y, Liu B, Yao J (2017) Analysis of graphene-based photonic crystal fiber sensor using birefringence and surface plasmon resonance. Plasmonics 12:489–496

    Article  CAS  Google Scholar 

  13. Liu C, Yang L, Liu Q, Wang F, Sun Z, Sun T, Mu H, Chu PK (2018) Analysis of a surface plasmon resonance probe based on photonic crystal fibers for low refractive index detection. Plasmonics 13:779–784

    Article  CAS  Google Scholar 

  14. Wang F, Liu C, Sun Z, Sun T, Liu B, Chu PK (2018) A highly sensitive SPR sensors based on two parallel PCFs for low refractive index detection. IEEE Photonics 10(4):1–10

    Google Scholar 

Download references

Acknowledgments

The authors thank Dalhousie University for providing resources.

Funding

This study was financially supported by an Abu Dhabi Award for Research Excellence grant (AARE-114).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yashar Esfahani Monfared.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Esfahani Monfared, Y., Qasymeh, M. Plasmonic Biosensor for Low-Index Liquid Analyte Detection Using Graphene-Assisted Photonic Crystal Fiber. Plasmonics 16, 881–889 (2021). https://doi.org/10.1007/s11468-020-01308-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11468-020-01308-2

Keywords

Navigation