Abstract
The purpose of this study was to develop fully 3D image reconstruction techniques for pinhole SPECT imaging with our Micro-SPECT system. Our studies involve in the derivation of projection operators, analysis of the sampling characteristics of pinhole SPECT imaging in Radon space, development of effective geometric calibration method for system misalignment, and 3D image reconstruction development and implementation with quantitative degrading compensation for pinhole SPECT with both circular and helical scan. The performances of pinhole SPECT imaging were evaluated using computer simulations and experiments with the Ultra-Micro Hot-Spot phantom, Ultra-Micro Defrise phantom and small-animal imaging. The results from the computer simulations and phantom imaging experiments indicate that the statistically-based iterative algorithms with quantitative compensation provide overall image quality improvement, and the system resolution is significantly recovered for quantitative imaging. The helical pinhole SPECT improves the axial field-of-view (FOV) as compared with the standard pinhole SPECT with circular-orbit scan. The mouse bone imaging experiment shows that the helical pinhole SPECT imaging also provides decent high-resolution whole-body small animal imaging. In conclusion, we have successfully developed a set of valid fully 3D image reconstruction techniques for single-pinhole SPECT imaging. These techniques can be easily extended to multi-pinhole SPECT imaging.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Blankenberg F G. Molecular imaging with single photon emission computed tomography. IEEE Eng Med Biol, 2004, 23: 51–57
Meikle S R, Kench P, Kassiou M, et al. Small animal SPECT and its place in the matrix of molecular imaging technologies. Phys Med Biol, 2005, 50: R45–R61
Kupinski M A, Barrett H H. Small-animal SPECT Imaging. New York: Springer Press, 2005
Qi Y J. High-resolution SPECT for small-animal imaging. Nucl Sci Tech, 2006, 17: 164–169
Tsui B M W, Wang Y, Yoder B C, et al. Micro-SPECT. In: Proceedings of IEEE International Symposium on Biomedical Imaging, 2002, IEEE Press, 373–376
Furenlid L R, Wilson D W, Chen Y, et al. FastSPECT II: A second-generation high-resolution dynamic SPECT imager. IEEE Trans Nucl Sci, 2004, 51: 631–635
Beekman F, Have F, The pinhole: Gateway to ultra-high-resolution three-dimensional radionuclide imaging. Eur J Nucl Med Mol Imaging, 2007, 34: 151–161
Qi Y J. Optimized collimator designs for small animal SPECT imaging with a compact gamma camera. In: 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2005, IEEE Press, 1780–1782
Metzler S D, Bowsher J E, Jaszczak R J. Geometrical similarities of the Orlov and Tuy sampling criteria and a numerical algorithm for assessing sampling completeness. IEEE Trans Nucl Sci, 2003, 50: 1550–1555
Metzler S D, Greer K L, Jaszczak R J. Helical pinhole SPECT for small-animal imaging: A method for addressing sampling completeness. IEEE Trans Nucl Sci, 2003, 50: 1575–1583
Tuy H K. An inversion formula for cone-beam reconstruction. SIAM J Appl Math, 1983, 43: 546–552
Smith B D. Image reconstruction from cone-beam projections: Necessary and sufficient condition and reconstruction methods. IEEE Trans Med Imaging, 1985, 4: 14–25
Orlov S S. Theory of three dimensional reconstruction. I. condition for a complete set of projections. Sov Phys Crystallogr, 1975, 20 312–314
Cherry S R, Sorenson J, Phelps M. Physics in Nuclear Medicine. 3rd ed. Philadelphia, Pa: Saunders/Elsevier Science Press, 2003
Barrett H H, Mayer K J. Foundations of Image Science. New York Wiley-Interscience Press, 2003
Herman G T. Fundamentals of Computerized Tomography: Image Reconstruction from Projections. San Francisco: Academic Press, 1980
Natter F, Wubbeling F. Mathematical Methods in Imaging Reconstruction. SIAM Press, 2001
Shepp L A, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging, 1982, 1: 113–122
Lange K and Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr, 1984, 8: 306–316
Qi J Y, Leahy R M. Iterative reconstruction techniques in emission computed tomography. Phys Med Biol, 2006, 51: R541–R578
Hudson H M, Larkin R S. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging, 1994, 13: 601–609
Zhang X Z, Dai Q S, Qi Y J. Implementing analytical geometric and penetration response correction for keel-edge pinhole SPECT image reconstruction. In: IEEE Nuclear Science Symposium Conference Record, 2008, IEEE Press, 5255–5259
Zhang X Z, Chen F F, Qi Y J, et al. Unified Geometric Calibration and Image Registration for Detached Small Animal SPECT/CT. In: IEEE Nuclear Science Symposium Conference Record, 2009, IEEE Press, 3318–3321
Beque D, Nuyts J, Bormans G, et al. Characterization of pinhole SPECT acquisition geometry. IEEE Trans Med Imaging, 2003. 22: 599–612
Wang Y. Development and application of high-sensitivity and high-resolution fully 3D SPECT imaging techniques using two different collimator designs. Doctor Dissertation. Chapel Hill: The University of North Carolina, 2004
Wang Y, Tsui B M W. Pinhole SPECT with different data acquisition geometries: usefulness of unified projection operators in homogeneous coordinates. IEEE Trans Med Imaging, 2007, 26: 298–308
Press W H, Teukolsky S A, Vetterling W T, et al. Numerical Recipes in C: The Art of Scientific Computing, 2nd ed. Cambridge, U.K.: Cambridge University Press, 1992
Zhang M J, Qi Y J. Readout electronics of a high-resolution gamma camera (in Chinese). Nuclear Tech, 2007, 30: 629–632
Qi Y J, Zhang M J, Zhao C L, et al. Performance comparison of subtractive resistive readout with conventional resistive readout for high-resolution compact gamma camera. In: IEEE Nuclear Science Symposium Conference Record, 2007, IEEE Press, 3725–3728
Zhang M J. Study of readout electronics of Micro-SPECT (in Chinese). Master Thesis. Beijing: Graduate University of Chinese Academy of Sciences, 2007
Author information
Authors and Affiliations
Corresponding authors
Additional information
This article is published with open access at Springerlink.com
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Zhang, X., Qi, Y. Development of fully 3D image reconstruction techniques for pinhole SPECT imaging. Chin. Sci. Bull. 56, 340–348 (2011). https://doi.org/10.1007/s11434-010-3200-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11434-010-3200-x