Abstract
Beam angular divergence is one of the indicators to evaluate the beam quality. Operating parameters of the beam extraction system could be adjusted to gain better beam quality following the measurement results, which will be helpful not only to study the transmission characteristics of the beam and the power distribution on the heat load components, but also to understand the real-time working condition of the ion source and beam extraction system. This study includes: (1) the theoretical analysis of beam extraction pulse duration for measurement of beam angular divergence; (2) the theoretical analysis of beam intensity distribution during beam transmission for Experimental Advanced Superconducting Tokomak (EAST) neutral beam injector. Those theoretical analyses could point the way to the measurement of beam divergence angle for EAST neutral beam injector.
Similar content being viewed by others
References
Fowler R H, Morris R N, Rome J A. A study of neutral beam injection for the advanced toroidal facility. Fusion Tech, 1991, 20: 200–207
Listopad A A, Coenen J W, Davydenko V I, et al. Operation and upgrade of diagnostic neutral beam injector RUDI at TEXTOR tokamak. Rev Sci Instrum, 2010, 81: 02B104
Kuroda T, Kaneko O, Takeiri Y, et al. Energetic negative ion source for fusion at NIFS. Rev Sci Instrum,1996, 67: 1114–1119
Itoh T, Akino N, Ebisawa N, et al. Beam performance of negative-ion based NBI system for JT-60. Fusion Eng Des, 2000, 51-2: 1039–1047
Yoo S J, Yang H L, Hwang S M. Measurement of angular divergence and ion species ratios of an rf-driven multicusp ion source for diagnostic neutral beam by Doppler shift spectroscopy. Rev Sci Instrum, 2000, 71: 1421–1425
Hu L, Kuriyama M, Akino N, et al. Beam divergence and power loading on the beamline components of the negative-ion based NBI system for JT-60U. Fusion Eng Des, 2001, 54: 321–330
Oka Y, Tsumori K, Takeiri Y, et al. High current H− ion sources for the large helical device neutral beam injector. Rev Sci Instrum, 1998, 69: 920–922
Kugel H W, Gammel G M, Grisham L R, et al. Measurements of neutral beam species, impurities, spatial divergence, energy dispersion, pressure, and reionization using the TFTR U.S. Common long pulse ion source. Rev Sci Instrum, 1989, 60: 37–52
Day I E, Gee S. Direct measurement of neutral/ion beam power using thermocouple analysis. Fusion Eng Des, 2007, 82: 806–812
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xu, Y., Hu, C. Theoretical analysis of some problems in the measurement of beam divergence angle for EAST neutral beam injector. Sci. China Phys. Mech. Astron. 54 (Suppl 2), 300–304 (2011). https://doi.org/10.1007/s11433-011-4546-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11433-011-4546-z