Abstract
A mini-vane four-rod radio frequency quadruple (RFQ) accelerator has been built for neutron imaging. The RFQ will operate at 201.5 MHz, and its length is 2.7 m. The original electric field distribution along the electrodes is not flat. The resonant frequency needs to be tuned to the operating value. And the frequency needs to be compensated for temperature change during high power RF test and beam test. As tuning such a RFQ is difficult, plate tuners and stick tuners are designed. This paper will present the tuners design, the tuning procedure, and the RF properties of the RFQ.
Similar content being viewed by others
References
Gillespie G H, McMichael G E. Applications of MeV Proton and Deuteron Linear Accelerators. In: Proceedings of Particle Accelerator Conference. Dallas: IEEE, 1995
Zhang C, Guo Z Y, Schempp A, et al. Design of a high current RFQ for neutron production. Nucl Instrum Methods Phys Res Sect A, 2003, 521(2–3): 326–331
Wen W W, Li H, Zou Y B, et al. Neutronic design and simulated performance of Peking University Neutron Imaging Facility (PKU-NIFTY). Nucl Instrum Methods Phys Res Sect A, 2011, 651(1): 67–72
Fischer P, Schempp A. Tuning a CW 4-Rod RFQ. In: Proceedings of LINAC, 2006
Zhu K, Guo Z Y, Fang J X, et al. Simulation and experimental studies on a 4 rod RFQ RF property. Chin Phys C, 2005, 29(05): 512–516
Lu Y R, Guo J F, Li W G, et al. Investigation of 26 MHz RFQ accelerators. Nucl Instrum Methods Phys Res Sect A, 1999, 420(1–2): 1–5
Fang J X, Schempp A. Equivalent Circult of a 4-Rod RFQ. In: 3rd European Particle Accelerator Conference, 1992
Schempp A, Brendel L, Hofmann B, et al. Tuner Design for High Power 4-Rod RFQs. In: Proceedings of LINAC, 2004
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zhou, Q., Zhu, K., Guo, Z. et al. Tuner design and RF test of a four-rod RFQ. Sci. China Phys. Mech. Astron. 54 (Suppl 2), 271–273 (2011). https://doi.org/10.1007/s11433-011-4504-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11433-011-4504-9