Skip to main content
Log in

A real-size MRPC developed for CBM-TOF

  • Published:
Science China Technological Sciences Aims and scope Submit manuscript

Abstract

An MRPC prototype for the future CBM-TOF inner area has been developed. The counter assembled with low resistive glass consists of 10×0.22 mm gas gaps and 2×8 readout pads. The size of each pad is 20 mm×20 mm with an interval of 2 mm between pads. The signals of the counter are collected by 4 eight-pin connectors. Preliminary tests performed with cosmic-rays showed an efficiency over 98% and a time resolution around 60 ps. The measured crosstalk, dark current and dark rate were at a very low levels. Results under uniform irradiation performed at JINR with high energy deuteron showed a time resolution of 40–50 ps and over 98% efficiency at a low flux rate, meanwhile at a flux up to 70 kHz/cm2, 93% efficiency and 77 ps time resolution still remained. These excellent performances call fully meet the demand of CBM-TOF inner wall.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Santonico R, Cardarelli R. Development of resistive plate counters. Nucl Instr Meth A, 1981, 187: 377–380

    Article  Google Scholar 

  2. Akindinov A, Alici F, Anselmo P, et al. Latest results on the performance of the multi-gap resistive plate chamber used for the ALICE TOF. Nucl Instr Meth A, 2004, 533: 74–78

    Article  Google Scholar 

  3. Wang Y, Wang J B, Cheng J P, et al. Production and quality control of STAR-TOF MRPC. Nucl Instr Meth A, 2010, 613: 200–206

    Article  Google Scholar 

  4. Schüttauf A. Timing RPCs in FOPI. Nucl Instr Meth A, 2004, 533: 65–68

    Article  Google Scholar 

  5. Alvarez Pol H, Alves R, Blanco A, et al. A large area timing RPC prototype for ion collisions in the HADES spectrometer. Nucl Instr Meth A, 2004, 533: 277–282

    Article  Google Scholar 

  6. Deppner I, Herrmann N. A Multistrip-MRPC prototype for the CBM Time-of-Flight wall. PoS, 2012, 1: 16–22

    Google Scholar 

  7. Deppner I, Herrmann N, Gonzalez-Diaz D, et al. The CBM Time-of-flight wall. Nucl Instr Meth A, 2012, 661: 121–124

    Article  Google Scholar 

  8. Wang J B, Wang Y, Gonzalez-Diaz D, et al. Development of high-rate MRPCs for high resolution time-of-flight system. Nucl Instr Meth A, 2013, 713: 40–51

    Article  Google Scholar 

  9. Ciobanu M, Schuttauf A, Cordier E, et al. A Front-end electronics card comprising a high gain/high bandwidth amplifier and a fast discriminator for time-of-flight measurements. IEEE, 2007, 54: 1201–1206

    Google Scholar 

  10. Ciobanu M, Herrmann N, Hildenbrand K D, et al. PADI, a fast Preamplifier-discriminator for time-of-flight measurements. IEEE, 2008: 2018–2024

    Google Scholar 

  11. Ciobanu M, Herrmann N, Hildenbrand K D, et al. PADI-2,-3 and-4: The second iteration of the fast Preamplifier—Discriminator ASIC for time-of-flight measurements at CBM. IEEE, 2009: 401–406

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yi Wang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhu, W., Wang, Y., Feng, S. et al. A real-size MRPC developed for CBM-TOF. Sci. China Technol. Sci. 56, 2821–2826 (2013). https://doi.org/10.1007/s11431-013-5353-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11431-013-5353-8

Keywords

Navigation