Skip to main content
Log in

Prediction of the conducted EMI in PWM converter system with parasitic parameters considered

  • Published:
Science China Technological Sciences Aims and scope Submit manuscript

Abstract

This paper presents a new approach for modeling of the conducted electromagnetic interference (EMI) prediction for widely used converter systems. Coupling paths and mechanism of differential mode (DM) interference and common mode (CM) interference have been analyzed. Models to predict the high-frequency noise of PWM converter system are created. A direct calculation method in frequency domain is proposed for the deduction of frequency spectrum. A method is given for obtaining the parasitic parameters and topological structure of the model. An experimental investigation of the conducted emission from an actual high-power rectifier system is described. The validity of the models is confirmed by comparison to laboratory measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

We’re sorry, something doesn't seem to be working properly.

Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

References

  1. Qian Z M Chen H L. State of art of electromagnetic compatibility research on power electronic equipment (in Chinese). Trans China Electrotech Soc, 2007, 22(7): 1–11

    MathSciNet  Google Scholar 

  2. Zhao Z M, Bai H, Yuan L Q. Analysis of cutting-edge techniques in the high voltage and high power adjustable speed drive systems. Sci China Ser E-Tech Sci, 2009, 52(2): 442–449

    Article  Google Scholar 

  3. Yang L Y, Odendaal W G H. Measurement-based method to characterize parasitic parameters of the integrated power electronics modules. IEEE T Power Elect, 2007, 22(1): 54–62

    Article  Google Scholar 

  4. Pan Q J, MENG J, Li Y, et al. Electromagnetic interference research on a double-fed machine with AC double converter exciter (in Chinese). Proc CSEE, 2010, 30(15): 80–86

    Google Scholar 

  5. He J P, Jiang J G, Chen W. Study of the model of the EMI coupling paths of an off-line PWM converter (in Chinese). Trans China Electrotech Soc, 2004, 19(4): 56–60

    Google Scholar 

  6. Meng J, Ma W M, Zhang L, et al. High-frequency model of conduct ed EMI for PWM variable-speed drive systems (in Chinese). Proc CSEE, 2008, 28(15): 141–146

    Google Scholar 

  7. Pei X J, Zhang K, Kang Y, et al. Prediction of common mode conducted EMI in single phase PWM inverter (in Chinese). Proc CSEE, 2004, 24(8): 83–88

    Google Scholar 

  8. Ran L, Gokani S, Clare J, et al. Conducted electromagnetic emissions in induction motor drive systems. I. Time domain analysis and identification of dominant modes. IEEE T Power Elect, 1998, 13(4): 757–767

    Article  Google Scholar 

  9. Ran L, Gokani S, Clare J, et al. Conducted electromagnetic emissions in induction motor drive systems. II. Frequency domain models. IEEE T Power Elect, 1998, 13(4): 768–776

    Article  Google Scholar 

  10. Huang J, Xiong R, Wang Z, et al. SPWM control strategy to reduce inverter common-mode interferences based on three-phase four-leg structure (in Chinese). Trans China Electrotech Soc, 2009, 24(3): 110–115

    Google Scholar 

  11. Zhang Y G, Jiang Y Y, Fang H S, et al. Common mode EMI suppression based on simulated annealing algorithm (in Chinese). Trans China Electrotech Soc, 2008, 23(6): 1–6

    MATH  Google Scholar 

  12. Mihalic F, Kos D. Reduced conductive EMI in switched-mode DC-DC power converters without EMI filters: PWM versus randomized PWM. IEEE T Power Elect, 2006, 21(6): 1783–1794

    Article  Google Scholar 

  13. Wang S, Lee F C, Odendaal W G. Cancellation of capacitor parasitic parameters for noise reduction application. IEEE T Power Elect, 2006, 21(4): 1125–1132

    Article  Google Scholar 

  14. Tarateeraseth V, See K Y, Canavero F G. Accurate extraction of noise source impedance of a SMPS under operating. IEEE T Power Elect, 2010, 25(1): 111–117

    Article  Google Scholar 

  15. Zhu H B, Lai J S, Hefner A R, et al. Modeling-based examination of conducted EMI emissions from hard and soft-switching PWM inverters. IEEE T Power Elect, 2002, 37(5): 1383–1393

    Google Scholar 

  16. Wei K X, Liang B, Yue Y J. Prediction of the conducted EMI in converter system with asymmetric regular sampling modulation (in Chinese). Power Syst Technol, 2011, 35(6): 208–212

    Google Scholar 

  17. Yan D, Sun Y X, Sun L, et al. Analysis and suppression of crosstalk for T-saped microstrip line by using FDTD. J Electron Inform Technol, 2007, 29(9): 2283–2286

    Google Scholar 

  18. Chen W, Feng L M, Chen H L, et al. Near feld coupling effects on conducted EMI in power converter. IEEE PESC, 2006. 1–6

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bin Liang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Liang, B., Wei, K. & Yue, Y. Prediction of the conducted EMI in PWM converter system with parasitic parameters considered. Sci. China Technol. Sci. 55, 2829–2836 (2012). https://doi.org/10.1007/s11431-012-4925-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11431-012-4925-3

Keywords

Navigation