Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger

  • Published:
Science China Technological Sciences Aims and scope Submit manuscript

Abstract

In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Allan M L. Thermal Conductivity of Cementitious Grouts for Geothermal Heat Pumps. FY Progress Report, BNL 65129, 1997

  2. Allan M L, Philippacopoulos A. Thermally Conductive Cementitious Grouts for Geothermal Heat Pumps. FY Progress Report, BNL 66103, 1998

  3. Allan M L, Kavanaugh S P. Thermal conductivity of cementitious grouts and impact on heat exchanger length design for ground source heat pumps. Int J HVAC&R Res, 1999, 5: 87–98

    Google Scholar 

  4. Lee C, Lee K, Choi H, et al. Characteristics of ther-mally-enhanced bentonite grouts for geothermal heat exchanger in South Korea. Sci China Tech Sci, 2010, 53: 123–128

    Article  Google Scholar 

  5. Ministry of Construction and Transportation in Korea. Gwirae-Maejiri Geologic Profile. BB1-BB5, 1998

  6. Jun G, Xu Z, Jun L, et al. Thermal performance and ground temperature of vertical pile-foundation heat exchanger: A case study. Appl Therm Eng, 2008, 28: 2295–2304

    Article  Google Scholar 

  7. Niekamp A, Unklesbay K, Unklesbay N, et al. Thermal properties of bentonite-water dispersions used for modeling foods. J Food Sci, 1984, 49: 28–31

    Article  Google Scholar 

  8. Caslaw H S, Jaeger J C. Conduction of Heat in Solids. Oxford: Claremore Press, 1947

    Google Scholar 

  9. Gehlin S. Thermal response test-method development and evaluation. Dissertation of Doctoral Degree. Sweden: Lulea University of Technology, 2002

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hangseok Choi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Choi, J.M., Lee, C., Park, M. et al. Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger. Sci. China Technol. Sci. 54, 1668–1673 (2011). https://doi.org/10.1007/s11431-011-4389-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11431-011-4389-x

Keywords

Navigation