Abstract
In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger.
Similar content being viewed by others
References
Allan M L. Thermal Conductivity of Cementitious Grouts for Geothermal Heat Pumps. FY Progress Report, BNL 65129, 1997
Allan M L, Philippacopoulos A. Thermally Conductive Cementitious Grouts for Geothermal Heat Pumps. FY Progress Report, BNL 66103, 1998
Allan M L, Kavanaugh S P. Thermal conductivity of cementitious grouts and impact on heat exchanger length design for ground source heat pumps. Int J HVAC&R Res, 1999, 5: 87–98
Lee C, Lee K, Choi H, et al. Characteristics of ther-mally-enhanced bentonite grouts for geothermal heat exchanger in South Korea. Sci China Tech Sci, 2010, 53: 123–128
Ministry of Construction and Transportation in Korea. Gwirae-Maejiri Geologic Profile. BB1-BB5, 1998
Jun G, Xu Z, Jun L, et al. Thermal performance and ground temperature of vertical pile-foundation heat exchanger: A case study. Appl Therm Eng, 2008, 28: 2295–2304
Niekamp A, Unklesbay K, Unklesbay N, et al. Thermal properties of bentonite-water dispersions used for modeling foods. J Food Sci, 1984, 49: 28–31
Caslaw H S, Jaeger J C. Conduction of Heat in Solids. Oxford: Claremore Press, 1947
Gehlin S. Thermal response test-method development and evaluation. Dissertation of Doctoral Degree. Sweden: Lulea University of Technology, 2002
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Choi, J.M., Lee, C., Park, M. et al. Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger. Sci. China Technol. Sci. 54, 1668–1673 (2011). https://doi.org/10.1007/s11431-011-4389-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11431-011-4389-x