Skip to main content
Log in

A customized model for 3D human segmental kinematic coupling analysis by optoelectronic stereophotogrammetry

  • Published:
Science China Technological Sciences Aims and scope Submit manuscript

Abstract

The study of three-dimensional human kinematics has significant impacts on medical and healthcare technology innovations. As a non-invasive technology, optoelectronic stereophotogrammetry is widely used for in-vivo locomotor evaluations. However, relatively high testing difficulties, poor testing accuracies, and high analysis complexities prohibit its further employment. The objective of this study is to explore an improved modeling technique for quantitative measurement and analysis of human locomotion. Firstly, a 3D whole body model of 17 rigid segments was developed to describe human locomotion. Subsequently, a novel infrared reflective marker cluster for 17 body segments was constructed to calibrate and record the 3D segmental position and orientation of each functional body region simultaneously with high spatial accuracy. In addition, the novel calibration procedure and the conception of kinematic coupling of human locomotion were proposed to investigate the segmental functional characteristics of human motion. Eight healthy male subjects were evaluated with walking and running experiments using the Qualisys motion capture system. The experimental results demonstrated the followings: (i) The kinematic coupling of the upper limbs and the lower limbs both showed the significant characteristics of joint motion, while the torso motion of human possessed remarkable features of segmental motion; (ii) flexion/extension was the main motion feature in sagittal plane, while the lateral bending in coronal plane and the axial rotation in transverse plane were subsidiary motions during an entire walking cycle regarding to all the segments of the human body; (iii) compared with conventional methods, the improved techniques have a competitive advantage in the convenient measurement and accurate analysis of the segmental dynamic functional characteristics during human locomotion. The modeling technique proposed in this paper has great potentials in rehabilitation engineering as well as ergonomics and biomimetic engineering.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Medved V. Measurement of Human Locomotion. Boca Raton: CRC Press, 2001

    Google Scholar 

  2. Cappozzo A, Della C U, Leardini A, et al. Human movement analysis using stereophotogrammetry. Part 1: Theoretical background. Gait Posture, 2005, 21(2): 186–196

    Google Scholar 

  3. Della C U, Cappozzo A. A spot-check for estimating stereophotogrammetric errors. Med Biol Eng Comput, 2000, 38(3): 260–266

    Article  Google Scholar 

  4. Lucchetti L, Cappozzo A, Della C U. Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics. J Biomech, 1998, 31(11): 977–984

    Article  Google Scholar 

  5. Ehara Y, Fujimoto H, Miyazaki S, et al. Comparison of the performances of 3D camera systems. Gait Posture, 1995, 3(3): 166–169

    Article  Google Scholar 

  6. Branca F P, Cappa P. An experimental study of the accuracy and precision associated to an opto-electronic system utilized for gait analysis. In: 12th Triennial World Congress of the International Measurement Confederation (I.ME.KO.), Measurements Applications, 1991, Beijing, China

  7. Siegler S, Seliktar R, Hyman W. Simulation of human gait with the aid of a simple mechanical model. J Biomech, 1982, 15(6): 415–425

    Article  Google Scholar 

  8. McMahon T A. Mechanics of locomotion. Int J Robot Res, 1984, 3(2): 4–28

    Article  Google Scholar 

  9. Pandy M G, Berme N. A numerical method for simulating the dynamics of human walking. J Biomech, 1988, 21(12): 1043–1051

    Article  Google Scholar 

  10. Audu M L, Davy D T. The influence of muscle model complexity in musculoskeletal motion modeling. J Biomech Eng, 1985, 107(2): 147–157

    Article  Google Scholar 

  11. Buchanan T S, Shreeve D A. An evaluation of optimization techniques for the prediction of muscle activation patterns during isometric tasks. J Biomech Eng, 1996, 118(4): 565–574

    Article  Google Scholar 

  12. Piazza S J, Delp S L. The influence of muscles on knee flexion during the swing phase of gait. J Biomech, 1996, 29(6): 723–733

    Article  Google Scholar 

  13. Devita P. Effects of asymmetric load carrying on the biomechanics of walking. J Biomech, 1991, 24(12): 1119–1129

    Article  Google Scholar 

  14. Zhao G R, Ren L, Ren L Q, et al. Segmental kinematic coupling of the human spinal column during locomotion. J Bionic Eng, 2008, 5(4): 328–334

    Article  MathSciNet  Google Scholar 

  15. Cappozzo A. Gait analysis methodology. Hum Movement Sci, 1984, 3(1–2): 27–50

    Article  Google Scholar 

  16. Gamage S H U, Lasenby J. New least squares solutions for estimating the average centre of rotation and the axis of rotation. J Biomech, 2002, 35(1): 87–93

    Article  Google Scholar 

  17. Ren L, Jones R K, Howard D. Whole body inverse dynamics over a complete gait cycle based only on measured kinematics. J Biomech, 2008, 41(12): 2750–2759

    Article  Google Scholar 

  18. Ren L, Jones R, Howard D. Generalized approach to three-dimensional marker-based motion analysis of biomechanical multi-segment systems. In: International Society of Biomechanics XXth Congress, 2005, Cleveland, USA

  19. Winter D, Sidwall H, Hobson D A. Measurement and reduction of noise in kinematics of locomotion. J Biomech, 1974, 7(2): 157–159

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to LuQuan Ren.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhao, G., Ren, L., Tian, L. et al. A customized model for 3D human segmental kinematic coupling analysis by optoelectronic stereophotogrammetry. Sci. China Technol. Sci. 53, 2947–2953 (2010). https://doi.org/10.1007/s11431-010-4143-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11431-010-4143-9

Keywords

Navigation