Abstract
High-throughput pyrosequencing, carried out in millions of picoliter-sized reactors on a fiber-optic slide, is known for its longer read length. However, both optical crosstalk (which reduces the signal-to-noise ratio of CCD images) and chemical retention adversely affect the accuracy of chemiluminescence determination, and ultimately decrease the read length and the accuracy of pyrosequencing results. In this study, both titanium and oxidized aluminum films were deposited on the side walls and upper faces of micro-reactor slides to enhance optical isolation; the films reduced the inter-well crosstalk by one order of magnitude. Subsequently, chemical retention was shown to be caused by the lower diffusion coefficient of the side walls of the picoliter-sized reactors because of surface roughness and random pores. Optically isolated fiber-optic slides over-coated with silicon oxide showed smoother surface morphology, resulting in little chemical retention; this was further confirmed with theoretical calculations. Picoliter-sized micro-reactors coated with titanium-silicon oxide films showed the least inter-well optical crosstalk and chemical retention; these properties are expected to greatly improve the high-throughput pyrosequencing performance.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Sanger F, Nicklen S, Coulson A R. DNA sequencing with chain-terminating inhibitors. Proc Natl Acad Sci USA, 1977, 74: 5463–5467
Bains W, Smith G C. A novel method for nucleic acid sequence determination. J Theoret Biol, 1988, 135: 303–307
Drmanac R, Labat I, Brukner I, et al. Sequencing of megabase plus DNA by hybridization: Theory of the method. Genomics, 1989, 4: 114–128
Khrapko K R, Lysov Yu P, Khorlyn A A, et al. An oligonucleotide hybridization approach to DNA sequencing. FEBS Lett, 1989, 256: 118–122
Ronaghi M, Karamohamed S, Pettersson B, et al. Real-time DNA sequencing using detection of pyrophosphate release. Anal Biochem, 1996, 242: 84–89
Ronaghi M, Uhlen M, Nyren P. A sequencing method based on real-time pyrophosphate. Science, 1998, 281: 363–365
Brenner S, Williams S R, Vermaas E H, et al. In vitro cloning of complex mixtures of DNA on microbeads: Physical separation of differentially expressed cDNAs. Proc Natl Acad Sci USA, 2000, 97: 1665–1670
Margulies M, Egholm M, Altman W E. Genome sequencing in microfabricated high-density picolitre reactors. Nature, 2005, 437: 376–380
Meyer E, Aglyamova G V, Wang S, et al. Sequencing and de novo analysis of a coral larval transcriptome using 454 GSFlx. BMC Genomics, 2009, 10: 219–236
Ley T J, Mardis E R, Ding L, et al. DNA sequencing of a cytogenetically normal acute myeloid leukaemia genome. Nature, 2008, 456: 66–72
Li R Q, Fan W, Tian G, et al. The sequence and de novo assembly of the giant panda genome. Nature, 2010, 463: 311–317
Krober M, Bekel T, Diaz N N, et al. Phylogenetic characterization of a biogas plant microbial community integrating clone library 16S-rDNA sequences and metagenome sequence data obtained by 454-pyrosequencing. J Biotechnol, 2009, 142: 38–49
Petrosino J F, Highlander S, Luna R A, et al. Metagenomic pyrosequencing and microbial identification. Clin Chem, 2009, 55: 856–866
Leamon J H, Rothberg J M. Cramming more sequencing reactions onto microreactor chips. Chem Rev, 2007, 107: 3367–3376
Rothberg J M, Leamon J H. The development and impact of 454 sequencing. Nat Biotechnol, 2008, 26: 1117–1124
Walt D R. Fibre optic microarrays. Chem Soc Rev, 2010, 39: 38–50
Epstein J R, Leung P K, Lee K H, et al. High-density, microsphere-based fiber optic DNA microarrays. Biosens Bioelectron, 2003, 18: 541–546
Pantano P, Walt D R. Analytical applications of optical imaging fibers. Anal Chem, 1995, 65: 481–487
Yuan L N, Ren L F, Li Y T, et al. A complete genome assembly of Glaciecola mesophila sp. nov. sequenced by using BIGIS-4 sequencer system. Sci China Life Sci, 2011, 54: 835–840
Pantano P, Walt D R. Ordered nanowell arrays. Chem Mater, 1996, 8: 2832–2835
Pangaribuan T, Yamada K, Jiang S D, et al. Reproducible fabrication technique of nonametric tip diameter fiber probe for photon scanning tunneling microscope. Jpn J Appl Phys, 1992, 31: 1302–1304
Leamon J H, Lee W L, Tartaro K R, et al. A massively parallel Pico-TiterPlate based platform for discrete picoliter-scale polymerase chain reactions. Electrophoresis, 2003, 24: 3769–3777
Han W J, Wei Q Q, Li Y T, et al. Fabrication of SU8-based chip suitable for genomic sequencing. Acta Phys Sin, 2013, 14: 148701
Shoffner M A, Cheng J, Hvichia G E, et al. Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR. Nucl Acids Res, 1996, 24: 375–379
Wilding P, Kricka L J, Cheng J, et al. Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers. Anal Biochem, 1998, 257: 95–100
Taylor T B, Winn-Deen E S, Picozza E, et al. Optimization of the performance of the polymerase chain reaction in silicon-based microstructures. Nucl Acids Res, 1997, 25: 3164–3168
Ronaghi M. Pyrosequencing sheds light on DNA sequencing. Genome Res, 2001, 11: 3–11
Macleod H A. Thin-film Optical Filters. London: Institute of Physics Publishing, 1986
Li J X, Zhao Y M. Biocompatibility and antibacterial performance of titanium by surface treatment. J Coat Technol Res, 2012, 9: 223–228
Lin C C, Cheng H C, Huang C F, et al. Enhancement of biocompatibility on bioactive titanium surface by low-temperature plasma treatment. Jpn J Appl Phys, 2005, 44: 8590–8598
La Flammea K E, Popatb K C, Leonic L, et al. Biocompatibility of nanoporous alumina membranes for immunoisolation. Biomaterials, 2007, 28: 2638–2645
Tercero J E, Namin S, Lahiri D, et al. Effect of carbon nanotube and aluminum oxide addition on plasma-sprayed hydroxyapatite coating’s mechanical properties and biocompatibility. Mat Sci Eng C-Bio S, 2009, 29: 2195–2202
Coppens M O. Characterization of fractal surface roughness and its influence on diffusion and reaction. Colloid Surface A, 2001, 187: 257–265
Jun C, Penga X F, Lee D J. Diffusion coefficient of Brownian particle in rough micro-channel. J Colloid Interf Sci, 2006, 296: 737–742
Hay K M, Dragilab M I, Liburdy J. Theoretical model for the wetting of a rough surface. J Colloid Interf Sci, 2008, 325: 472–477
Ren J, Ganapathysubramanian B, Sundararajan S. Experimental analysis of the surface roughness evolution of etched glass for micro/nanofluidic devices. J Micromech Microeng, 2011, 21: 025012
Kuhner M, Tampe R, Sackmann E. Lipid mono- and bilayer supported on polymer films: Composite polymer-lipid films on solid substrates. Biophys J, 1994, 67: 217–226
Seu K J, Pandey A P, Haque F, et al. Effect of surface treatment on diffusion and domain formation in supported lipid bilayers. Biophys J, 2007, 92: 2445–2450
Burlatsky S F, Oshanin G, Cazabat A M, et al. Microscopic model of upward creep of an ultrathin wetting film. Phys Rev Lett, 1995, 76: 86–89
Author information
Authors and Affiliations
Corresponding authors
Additional information
Contributed equally to this work
This article is published with open access at Springerlink.com
Electronic supplementary material
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Han, W., Yuan, L., Wei, Q. et al. Improved picoliter-sized micro-reactors for high-throughput biological analysis. Sci. China Life Sci. 56, 1134–1141 (2013). https://doi.org/10.1007/s11427-013-4564-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11427-013-4564-3