Copper is an essential element in the environment and the human body, but at the same time, exposure to high concentrations of Cu2+ ions will potentially lead to acute toxicity and various neurodegenerative diseases. Thus, it is of great significance for the development of highly sensitive and selective strategies for the detection of Cu2+ ions. Here, we report a highly efficient poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) (PEDOT:PSS) based organic electrochemical transistor (OECT) sensor, for real-time Cu2+ ions detection. The detection limit of the OECT device is as low as 100 nM, far beyond the sensitivity required for practical uses. The detection mechanism may base on the chemical reactivity of Cu2+ ions oxiding the PEDOT:PSS in solution both in absence and presence of the base potential. The OECT devices also exhibit excellent selective response to Cu2+ ions rather than other metal ions. Finally, we also demonstrate the determination of Cu2+ ions in tap water with the OECT Cu2+ sensor. Considering the high sensitivity and selectivity, as well as the real-time and low cost features of our Cu2+ OECT sensor, it is ideal for portable and disposable applications for environment monitoring and public health.
This is a preview of subscription content, access via your institution.
References
Fraga CG. Mol Aspects Med, 2005, 26: 235–244
Kanumakala S, Boneh A, Zacharin M. J Inherit Metab Dis, 2002, 25: 391–398
Uriu-Adams JY, Keen CL. Mol Aspects Med, 2005, 26: 268–298
Schaefer M, Schellenberg M, Merle U, Weiss KH, Stremmel W. BMC Gastroenterol, 2008, 8: 29
Drew SC, Barnham KJ. Acc Chem Res, 2011, 44: 1146–1155
Mohd-Taufek N, Cartwright D, Davies M, Hewavitharana AK, Koorts P, Shaw PN, Sumner R, Lee E, Whitfield K. Food Anal Methods, 2016, 9: 2068–2075
Mendil D, Karatas M, Tuzen M. Food Chem, 2015, 177: 320–324
Chen YZ, Jiang HL. Chem Mater, 2016, 28: 6698–6704
Ocypa M, Michalska A, Maksymiuk K. Electrochim Acta, 2006, 51: 2298–2305
Lin M, Cho MS, Choe WS, Son Y, Lee Y. Electrochim Acta, 2009, 54: 7012–7017
Gao W, Nyein HYY, Shahpar Z, Fahad HM, Chen K, Emaminejad S, Gao Y, Tai LC, Ota H, Wu E, Bullock J, Zeng Y, Lien DH, Javey A. ACS Sens, 2016, 1: 866–874
Yan F, Tang H. Expert Rev Mol Diagn, 2010, 10: 547–549
Tang H, Lin P, Chan HLW, Yan F. Biosens Bioelectron, 2011, 26: 4559–4563
Liao C, Zhang M, Niu L, Zheng Z, Yan F. J Mater Chem B, 2014, 2: 191–200
Liao C, Mak C, Zhang M, Chan HLW, Yan F. Adv Mater, 2015, 27: 676–681
Liao J, Lin S, Yang Y, Liu K, Du W. Sensor Actuat B-Chem, 2015, 208: 457–463
He RX, Zhang M, Tan F, Leung PHM, Zhao XZ, Chan HLW, Yang M, Yan F. J Mater Chem, 2012, 22: 22072–22076
Lin P, Luo X, Hsing IM, Yan F. Adv Mater, 2011, 23: 4035–4040
Lin P, Yan F, Yu J, Chan HLW, Yang M. Adv Mater, 2010, 22: 3655–3660
Dabke RB, Singh GD, Dhanabalan A, Lal R, Contractor AQ. Anal Chem, 1997, 69: 724–727
Mousavi Z, Ekholm A, Bobacka J, Ivaska A. Electroanalysis, 2009, 21: 472–479
Wang Y, Zhou Z, Qing X, Zhong W, Liu Q, Wang W, Li M, Liu K, Wang D. Anal Bioanal Chem, 2016, 408: 5779–5787
Bernards DA, Malliaras GG. Adv Funct Mater, 2007, 17: 3538–3544
Lin P, Yan F, Chan HLW. ACS Appl Mater Interfaces, 2010, 2: 1637–1641
Xia Y, Ouyang J. Org Electron, 2010, 11: 1129–1135
Tian Y, Wang Y, Xu Y, Liu Y, Li D, Fan C. Sci China Chem, 2015, 58: 514–518
Wang Y, Cui Y, Liu R, Gao F, Gao L, Gao X. Sci China Chem, 2015, 58: 819–824
de Bethune AJ, Loud NAS, King CV. J Electrochem Soc, 1965, 112: 107C–108C
Acknowledgments
This work was supported by the Key Science & Technology Specific Projects of Anhui Province (15czz03117), the Funds for Huangshan Professorship of Hefei University of Technology (407-037019), Anhui Science and Technology Research Projects of China (1401b042018), and the Fundamental Research Funds for the Central Universities (JZ2017HGTB0195, JZ2016HGBZ1047).
Author information
Authors and Affiliations
Corresponding authors
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Xiong, C., Qu, H., Chen, W. et al. Real-time detection of Cu(II) with PEDOT:PSS based organic electrochemical transistors. Sci. China Chem. 60, 1205–1211 (2017). https://doi.org/10.1007/s11426-016-9013-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11426-016-9013-0