Abstract
In this work, we chose tris(2,2′-bipyridyl)ruthenium(II)hexafluorophosphate (Ru(bpy)3(PF6)2), a metal-organic complex material, to prepare nanowires, which were subsequently applied for the construction of electrochemiluminescence (ECL) biosensor by immobilizing them onto a glassy carbon electrode (GCE) with graphene-Nafion composite films. The graphene therein, being a two-dimensional carbon nanomaterial with outstanding electronic properties, can obviously improve the conductivity of the Nafion film, as well as enhance the electrochemical signal and ECL intensity of the Ru(bpy)3(PF6)2 nanowires (RuNWs) at low graphene concentration. The developed biosensor exhibited excellent ECL stability with tripropylamine (TPrA) as co-reactant. The ECL biosensor exhibited high sensitive ECL response in a wide linear range and low detection limit for the detection of proline. It is considered that the oxidation products of proline would be responsible for the ECL enhancement. The large electro-active area of the nanowires and the enhancement effect of the graphene played critical roles in the high detection performance of the ECL biosensor. The results demonstrated herein may provide a useful enlightenment for the design of more sensitive ECL biosensors.
Similar content being viewed by others
References
Richter MM. Chem Rev, 2004, 104: 3003–3036
Tian D, Duan C, Wang W, Cui H. Biosens Bioelectron, 2010, 25: 2290–2295
Chai Y, Tian D, Gu J, Cui H. Analyst, 2011, 136: 3244–3251
Chen XM, Wu GH, Chen JM, Jiang YQ, Chen GN, Oyama M, Chen X, Wang XR. Biosens Bioelectron, 2010, 26: 872–876
Wang J, Xu Y, Liu M, Niu F, Liu J. Electroanalysis, 2016, 28: 936–939
Gu W, Deng X, Gu X, Jia X, Lou B, Zhang X, Li J, Wang E. Anal Chem, 2015, 87: 1876–1881
Guo Z, Dong S. Anal Chem, 2004, 76: 2683–2688
Chen L, Cai Q, Luo F, Chen X, Zhu X, Qiu B, Lin Z, Chen G. Chem Commun, 2010, 46: 7751–7753
Zhao YS, Wu J, Huang J. J Am Chem Soc, 2009, 131: 3158–3159
Dong Y, Chen C, Lin J, Zhou N, Chi Y, Chen G. Carbon, 2013, 56: 12–17
Cui QH, Zhao YS, Yao J. Sci Sin Chim, 2011, 41: 1240
Yao W, Han G, Huang F, Chu M, Peng Q, Hu F, Yi Y, Jiang H, Yao J, Zhao YS. Adv Sci, 2015, 2: 1150–1158
Zheng JY, Yan Y, Wang X, Shi W, Ma H, Zhao YS, Yao J. Adv Mater, 2012, 24: OP194–OP199
Zheng JY, Zhang C, Zhao YS, Yao J. Phys Chem Chem Phys, 2010, 12: 12935–12938
Guo GM, Chen QA, Chen X. Sci China Chem, 2011, 54: 1777–1781
Omer KM, Bard AJ. J Phys Chem C, 2009, 113: 11575–11578
Suk J, Wu Z, Wang L, Bard AJ. J Am Chem Soc, 2011, 133: 14675–14685
Deng S, Ju H. Analyst, 2013, 138: 43–61
Feng Q, Chen H, Xu J. Sci China Chem, 2015, 58: 810–818
Li LL, Liu KP, Yang GH, Wang CM, Zhang JR, Zhu JJ. Adv Funct Mater, 2011, 21: 869–878
Wang CZ, E YF, Fan LZ, Wang ZH, Liu HB, Li YL, Yang SH, Li YL. Adv Mater, 2007, 19: 3677–3681
Li Q, Zheng JY, Yan Y, Zhao YS, Yao J. Adv Mater, 2012, 24: 4745–4749
Long TR, Richter MM. Inorg Chim Acta, 2005, 358: 2141–2145
Li Y, Huang C, Zheng J, Qi H, Cao W, Wei Y. Biosens Bioelectron, 2013, 44: 177–182
Miao C, Wu B, Cao H, Jia N. Anal Methods, 2014, 6: 8592–8597
Wei H, Du Y, Kang J, Wang E. Electrochem Commun, 2007, 9: 1474–1479
Robinson WD, Richter MM. Luminescence, 2015, 30: 67–71
Jang J, Lee WY. J Electroanal Chem, 2015, 736: 55–60
Zhang A, Miao C, Shi H, Xiang H, Huang C, Jia N. Sensor Actuat B-Chem, 2016, 222: 433–439
Mao L, Yuan R, Chai Y, Zhuo Y, Yang X, Yuan S. Talanta, 2010, 80: 1692–1697
Wang XF, Zhou Y, Xu JJ, Chen HY. Adv Funct Mater, 2009, 19: 1444–1450
Ding SN, Xu JJ, Chen HY. Chem Commun, 2006, 3631
Gui G, Zhuo Y, Chai Y, Liao N, Zhao M, Han J, Xiang Y, Yuan R. RSC Adv, 2014, 4: 1955–1960
Wang Y, Lu J, Tang L, Chang H, Li J. Anal Chem, 2009, 81: 9710–9715
Sohn K, Joo Na Y, Chang H, Roh KM, Dong Jang H, Huang J. Chem Commun, 2012, 48: 5968–5970
Avouris P, Freitag M. IEEE J Sel Top Quan, 2014, 20: 72–83
Tian Y, Wang Y, Xu Y, Liu Y, Li D, Fan C. Sci China Chem, 2015, 58: 514–518
Gu W, Xu Y, Lou B, Lyu Z, Wang E. Electrochem Commun, 2014, 38: 57–60
Li G, Yu X, Liu D, Liu X, Li F, Cui H. Anal Chem, 2015, 87: 10976–10981
Fan FRF, Park S, Zhu Y, Ruoff RS, Bard AJ. J Am Chem Soc, 2009, 131: 937–939
Kulkarni GS, Reddy K, Zhong Z, Fan X. Nat Commun, 2014, 5: 4376
Sun H, Li L, Wu Y. Drug Test Anal, 2009, 1: 87–92
Che Y, Yang X, Loser S, Zang L. Nano Lett, 2008, 8: 2219–2223
Bruce D, Richter MM. Anal Chem, 2002, 74: 1340–1342
Gómez-Mingot M, Alcaraz LA, MacIntyre DA, Jiménez B, Pineda-Lucena A, Montiel V, Banks CE, Iniesta J. Anal Methods, 2012, 4: 284–290
Mandrioli R, Morganti E, Mercolini L, Kenndler E, Raggi MA. Electrophoresis, 2011, 32: 2809–2815
Wang S, Yu J, Wan F, Ge S, Yan M, Zhang M. Anal Methods, 2011, 3: 1163–1167
Du Y, Wei H, Kang J, Yan J, Yin X, Yang X, Wang E. Anal Chem, 2005, 77: 7993–7997
Acknowledgments
This work was supported by the National Natural Science Foundation of China (21406053, 21521062), the Ministry of Science and Technology of China (2012YQ120060), Natural Science Foundation of Hebei Province (B2016208082), Science and Technology Research Projects in Hebei Universities (QN2015243, YQ2014015), and Five Platform Open Fund Projects of Hebei University of Science and Technology (2014YY25).
Author information
Authors and Affiliations
Corresponding authors
Electronic supplementary material
11426_2016_457_MOESM1_ESM.pdf
Electrochemiluminescence of Metal-Organic Complex Nanowires Based on Graphene-Nafion Modified Electrode for Biosensing Application
Rights and permissions
About this article
Cite this article
Li, Q., Kang, C., Li, K. et al. Electrochemiluminescence of metal-organic complex nanowires based on graphene-Nafion modified electrode for biosensing application. Sci. China Chem. 60, 642–648 (2017). https://doi.org/10.1007/s11426-016-0457-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11426-016-0457-9