Abstract
Two rainwater harvesting systems, which included first-flush diversion devices, connected to the roofs of two adjacent buildings, were monitored for water quality. The roofs were constructed from different materials, i.e., one roof was covered with ceramic tiles and the other was made of concrete. Water quality samples from the two storage tanks and the first-flush devices were collected and analyzed, showing satisfactory water quality in the tanks for residential non-potable use, while the water in the first-flush device was of poorer quality. Between the two collection surfaces, statistically significant differences were found only in the concentrations of NH4-N, orthophosphate, and Ca2+. Total coliforms were detected in both the storage tanks and the first-flush devices, indicating that disinfection of harvested rainwater may be necessary if it is collected for potable uses. Finally, first-flush water quality was related to antecedent dry days, showing that when the number of dry days increased, the accumulation of materials on the concrete roof was reduced while it was increased on the ceramic tile roof. This is attributed to the fact that the concrete roof is nearly horizontal (very slightly sloped), and the wind action easily removes various materials which accumulate on it.
Similar content being viewed by others
References
Adler I, Campos LC, Hudson-Edwards KA (2011) Converting rain into drinking water: quality issues and technological advances. Water Sci Technol 11(6):659–667
Adler I, Hudson-Edwards KA, Campos LC (2013) Evaluation of a silver-ion based purification system for rainwater harvesting at a small-scale community level. J Water Supply Res Technol AQUA 62(8):545–551
Ahmed W, Vieritz A, Goonetilleke A, Gardner T (2010) Health risk from the use of roof-harvested rainwater in Southeast Queensland, Australia, as potable or nonpotable water, determined using quantitative microbial risk assessment. Appl Environ Microbiol 76(22):7382–7391
Ahmed W, Gardner T, Toze Z (2011) Microbiological quality of roof harvested rainwater and health risks: a review. J Environ Qual 40:1–9
APHA, AWWA (1998) Standard methods for the examination of water and wastewater, (20th Edn). American Public Health Association, American Water Works Association, Washington, D.C.
Başak B, Alagha O (2004) The chemical composition of rainwater over Büyükçekmece Lake, Istanbul. Atmos Res 71:275–288
EU (1998) Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption. European Union, Official Journal of the European Communities 5.12.98
Evans CA, Coombes PJ, Dunstan RH (2006) Wind, rain and bacteria: the effect of weather on the microbial composition of roof-harvested rainwater. Water Res 40:37–44
Förster J (1999) Variability of roof runoff quality. Water Sci Technol 39(5):137–144
Gikas P, Angelakis AN (2009) Water resources management in Crete and in the Aegean Islands, with emphasis on the utilization of non-conventional water sources. Desalination 248:1049–1064
Gikas GD, Tsihrintzis VA (2012) Assessment of water quality of first-flush roof runoff and harvested rainwater. J Hydrol 466–467:115–126
Göbel P, Dierkes C, Coldewey WG (2007) Storm water runoff concentration matrix for urban areas. J Contam Hydrol 91:26–42
Gwenzi W, Nyamadzawo G (2014) Hydrological impacts of urbanization and urban roof water harvesting in water-limited catchments: a review. Environ Process 1:573–593
Gwenzi W, Dunjana N, Pisa C, Tauro T, Nyamadzawo G (2015) Water quality and public health risks associated with roof rainwater harvesting systems for potable supply: review and perspectives. Sustainability Water Qual Ecol 6:107–118
Haq SA (2017) Harvesting rainwater from buildings. Springer Nature, The Netherlands, 266p., ISBN 978-3-319-46360-6. doi:10.1007/978-3-319-46362-9
Helmreich B, Horn H (2009) Opportunities in rainwater harvesting. Desalination 248:118–124
Lee JY, Han MY, Kim H (2010) Review on codes and application of urban rainwater utilization: focused on case study in South Korea. Int J Urban Sci 14:307–319
Lim K-Y, Jiang SC (2013) Reevaluation of health risk benchmark for sustainable water practice through risk analysis of rooftop-harvested rainwater. Water Res 47:7273–7286
Londra PA, Theocharis AT, Baltas E, Tsihrintzis VΑ (2015) Optimal sizing of rainwater harvesting tanks for domestic use in Greece. Water Res Manag 29(12):4357–4377
Meera V, Ahammed MM (2006) Water quality of rooftop rainwater harvesting systems: a review. J Water Supply Res Technol AQUA 55:257–268
Melidis P, Akratos CS, Tsihrintzis VA, Trikilidou E (2007) Characterization of rain and roof drainage water quality in Xanthi, Greece. Environ Monit Assess 127:15–27
Mendez CB, Klenzendorf JB, Afshar BR, Simmons MT, Barrett ME, Kinney KA, Kirisits MJ (2011) The effect of roofing material on the quality of harvested rainwater. Water Res 45(5):2049–2059
Rouvalis A, Karadima C, Zioris IV, Sakkas VA, Albanis T, Iliopoulou-Georgudaki J (2009) Determination of pesticides and toxic potency of rainwater samples in western Greece. Ecotoxicol Environ Saf 72:828–833
Rowe MP (2011) Rainwater harvesting in Bermuda. J Am Water Res Assoc 47:1219–1227
Sazakli E, Alexopoulos A, Leotsinidis M (2007) Rainwater harvesting, quality assessment and utilization in Kefalonia Island, Greece. Water Res 41:2039–2047
Simmons G, Hope V, Lewis G, Whitmore J, Gao W (2001) Contamination of potable roof-collected rainwater in Auckland, New Zealand. Water Res 35(6):1518–1524
Taffere GR, Beyene A, Vuai SAH, Gasana J, Seleshi Y (2016) Characterization of atmospheric bulk deposition: implications on the quality of rainwater harvesting systems in the semi-arid City of Mekelle, Northern Ethiopia. Environ Process 3:247–261
Tsihrintzis VA, Baltas E (2014) Determination of rainwater harvesting tank size. Global NEST J 16(5):822–831
Valdez MC, Adler I, Barrett M, Ochoa R, Pérez A (2016) The water-energy-carbon nexus: optimising rainwater harvesting in Mexico City. Environ Process 3:307–323
Van Metre PC, Mahle BJ (2003) The contribution of particles washed from rooftops to contaminant loading to urban streams. Chemosphere 52:11127–11741
Vialle C, Sablayrolles C, Lovera M, Jacob S, Huau M-C, Montrejaud-Vignoles M (2011) Monitoring of water quality from roof runoff: interpretation using multivariate analysis. Water Res 45:3765–3775
WHO/UNICEF (2012) Progress on drinking water and sanitation 2012 update. World Health Organization/UNICEF Joint Monitoring Programme for Water Supply and Sanitation, Geneva ISBN: 972-924-1503297
Author information
Authors and Affiliations
Corresponding author
Additional information
Responsible editor: Philippe Garrigues
Rights and permissions
About this article
Cite this article
Gikas, G.D., Tsihrintzis, V.A. Effect of first-flush device, roofing material, and antecedent dry days on water quality of harvested rainwater. Environ Sci Pollut Res 24, 21997–22006 (2017). https://doi.org/10.1007/s11356-017-9868-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11356-017-9868-6