Abstract
We developed and evaluated the specificity and sensitivity of a simple loop-mediated isothermal amplification (LAMP) method for rapid detection of P. aeruginosa strains. The optimal reaction condition was found to be 65°C for 45 min, with the detection limit as 100 fg DNA/tube and 10 CFU/reaction. Application of LAMP assays were performed 426 clinical samples (including 252 P. aeruginosa and 174 non- P. aeruginosa isolates) using a rapid procedure and easy result confirmation. Sensitivity of LAMP and PCR assays was found to be 97.6% (246/252) and 90.5% (228/252), respectively; with a 100% specificity for both assays.
References
Deschaght P, de Baere T, van Simaey L, van Daele S, de Baets F, de Vos D, Pirnay JP, Vaneechoutte M (2009) Comparison of the sensitivity of culture, PCR and quantitative real-time PCR for the detection of Pseudomonas aeruginosa in sputum of cystic fibrosis patients. BMC Microbiol 9:244
Jarvis WR, Martone WJ (1992) Predominant pathogens in hospital infections. J Antimicrob Chemother 29(Suppl A):19–24
Lodeng AGG, Ahlen C, Lysvand H, Mandal LH, Iversen OJ (2006) Development and evaluation of a new PCR assay for detection of Pseudomonas aeruginosa D genotype. Clin Microbiol Infect 12:761–768
Schwartz T, Volkmann H, Kirchen S, Kohnen W, Schon-Holz K, Jansen B, Obst U (2006) Real-time PCR detection of Pseudomonas aeruginosa in clinical and municipal wastewater and genotyping of the ciprofloxacin-resistant isolates. FEMS Microbiol Ecol 57:158–167
Spencer RC (1996) Predominant pathogens found in the European prevalence of infection in intensive care study. Eur J Clin Microbiol Infect Dis 15:281–285
Xu Z, Shi L, Zhang C, Zhang L, Li X, Cao Y, Li L, Yamasaki S (2007) Nosocomial infection caused by class 1 integron-carrying Staphylococcus aureus in a hospital in South China. Clin Microbiol Infect 13:980–984
Xu Z, Li L, Alam MJ, Zhang L, Yamasaki S, Shi L (2008a) First confirmation of integron-bearing methicillin-resistant Staphylococcus aureus. Curr Microbiol 57:264–268
Xu Z, Shi L, Alam MJ, Li L, Yamasaki S (2008b) Integron-bearing methicillin-resistant coagulase-negative staphylococci in South China, 2001–2004. FEMS Microbiol Lett 278:223–230
Xu Z, Li L, Shirtliff ME, Alam MJ, Yamasaki S, Shi L (2009) Occurrence and characteristics of class 1 and 2 integrons in Pseudomonas aeruginosa isolates from patients in Southern China. J Clin Microbiol 47:230–234
Zhao X, Li Y, Wang L, You L, Xu Z, Li L, He X, Liu Y, Wang J, Yang L (2009) Development and application of a loop-mediated isothermal amplification method on rapid detection Escherichia coli O157 strains from food samples. Mol Biol Rep. doi: 10.1007/s11033-009-9700-6
Acknowledgments
This work was supported by Science Foundation of Ministry of Education of China (706046), National Natural Science Foundation of China (20436020) and State Scholarship Fund of China Scholarship Council (2008615044).
Author information
Authors and Affiliations
Corresponding authors
Additional information
Xihong Zhao and Li Wang contributed equally to this work.
Rights and permissions
About this article
Cite this article
Zhao, X., Wang, L., Li, Y. et al. Development and application of a loop-mediated isothermal amplification method on rapid detection of Pseudomonas aeruginosa strains. World J Microbiol Biotechnol 27, 181–184 (2011). https://doi.org/10.1007/s11274-010-0429-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11274-010-0429-0