Microscratching Characterization of the Wear-in of UHMW Polyethylene in Prostheses

  • Original Paper
  • Published:
Tribology Letters Aims and scope Submit manuscript

Abstract

A new measurement technique of prosthesis wear by microscratching has been demonstrated. The technique has been applied in a study of the backside wear of a UHMW polyethylene tibial insert of a rotating platform knee prosthesis. Four disc-shaped UHMW polyethylene plugs, prepared with 5-μm deep microscratches, were carefully recessed into the backside of the tibial insert. It was demonstrated that the scratches are not affected by creep under static load. A realistic in vitro wear simulation experiment was performed over 0.8 × 106 flexion cycles. SEM and AFM show that following the experiment the initial microscratches are effectively absent in all four locations with only residual depressions observed. This implies that typically at least 5 μm of polyethylene material was worn over the first 0.8 × 106 cycles by processes other than creep. Evidence from AFM and SEM indicates the in-fill and reintegration of polyethylene wear particles into residual scratch depressions. This supports a two-phase model of the wear process that has been independently confirmed by radioisotope tracing. For an initial wear-in phase, the model implies large, but rapidly decreasing, wear, resulting from abrasive wear and a competition between the loss and the reintegration of wear particles. The in vitro wear-in of the backside may typically produce a wear debris volume of 8.5 mm3. In addition to wear-in, the model assumes a much lower, constant long-term wear rate. The model has been used to correct published backside wear rates for the effects of the wear-in phase. A best estimate of 0.7 mm3/106 cycles has been determined for the long-term in vitro backside wear rate of a tibial insert in a rotating platform design.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Colizza, W.A., Insall, J.N., Scuderi, G.R.: The posterior stabilized total knee prosthesis: assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. J. Bone Jt. Surg. (Am.) 77-A, 1713–1720 (1995)

    Google Scholar 

  2. Kop, A.M., Swarts, E.: Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the anterior-posterior-glide (APG) and rotating platform (RP) low contact stress (LCS) knee. Acta Orthop. 78, 364–370 (2007)

    Article  Google Scholar 

  3. Akisue, T., Yamaguchi, M., Bauer, T.W., Takikawa, S., Schils, J.P., Yoshiya, S., Kurosaka, M.: “Backside” polyethylene deformation in total knee arthroplasty. J. Arthroplast. 18, 784–790 (2003)

    Article  Google Scholar 

  4. Conditt, M.A., Thompson, M.T., Usrey, M.M., Ismaiy, S.K., Noble, P.C.: Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss. J. Bone Jt. Surg. 87-A, 326–331 (2005)

    Article  Google Scholar 

  5. Berry, D.J., Currier, J.H., Mayor, M.B., Collier, J.P.: Knee wear measured in retrievals. Clin. Orthop. Relat. Res. 470, 1860–1868 (2012)

    Article  Google Scholar 

  6. Muratoglu, O.K., Rubash, H.E., Bragdon, C.R., Burroughs, B.R., Huang, A., Harris, W.H.: Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert. J. Arthroplast. 22, 435–443 (2007)

    Article  Google Scholar 

  7. Muratoglu, O.K., Bragdon, C.R., Jasty, M., O’Connor, D.O., Von Knoch, R.S., Harris, W.H.: Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts. J. Arthroplast. 19, 887–897 (2004)

    Article  Google Scholar 

  8. Yao, Y.Q., Laurent, M.P., Johnson, T.S., Mimnaugh, K., Blakemore, D., Blanchard, C.R., Crowninshield, R.D.: Backside wear of conventional and highly crosslinked UHMWPE tibial inserts as tested in a knee wear simulator. In: 29th Annual Meeting Transactions, Society for Biomaterials, 609 (2003)

  9. Crowninshield, R.D., Yao, J.Q., Wimmer, M.A., Jacobs, J.J., Rosenberg, A.G., Blanchard, C.R.: An assessment of polyethylene backside wear in a module tibial total knee system. In: 50th Annual Meeting of the Orthopaedic Research Society (2005)

  10. Atwood, S.A., Kennedy, F.E., Currier, J.H., Van Citters, D.W., Collier, J.P.: In vitro study of backside wear mechanisms on mobile knee-bearing components. J. Tribol. 128, 275–281 (2006)

    Article  CAS  Google Scholar 

  11. Atwood, S.A., Currier, J.H., Mayor, M.B., Collier, J.P., Citters, D.W., Kennedy, F.E.: Clinical wear measurement on low contact stress rotating platform knee bearings. J. Arthroplast. 23, 431–440 (2008)

    Article  Google Scholar 

  12. Furman, B.D., Schmieg, J.J., Bhattacharyya, S., Li, S.: The determination of backside wear in retrieved tibial inserts with four different locking mechanisms. In: 29th Annual Meeting Transaction, Society for Biomaterials, 493 (1999)

  13. Engh, G.A., Zimmerman, R.L., Parks, N.L., Engh, C.A.: Analysis of wear in retrieved mobile and fixed bearing knee inserts. J. Arthroplast. 24, 28–32 (2009)

    Article  Google Scholar 

  14. Gates, B.D.: Nanofabrication with molds and stamps. Mater. Today 8, 44–49 (2005)

    Article  CAS  Google Scholar 

  15. Liu, Y., Gladkis, L.G., Timmers, H.: Micro-scratching of UHMW polyethylene surfaces. Mater. Sci. Forum 654–656, 2455–2458 (2010)

    Article  Google Scholar 

  16. Warner, J.A., Gladkis, L.G., Smith, P.N., Scarvell, J.M., Timmers, H.: Demonstration of a new technique using radioisotope tracers to measure the backside wear rate on tibial inserts. Tribol. Lett. 46, 139–145 (2012)

    Article  CAS  Google Scholar 

  17. ProSim knee simulator, Simulation Solutions Ltd., UK, http://www.prosim.co.uk/knee.shtml (2012). Accessed 25 Oct 2012

  18. Low contact stress rotating platform system, DePuy Orthopaedics, Inc., USA, http://www.depuy.com/healthcare-professionals/product-details/lcs-completetrade-knee-system (2012). Accessed 25 Oct 2012

  19. Goldsmith, A.A.J., Dowson, D., Isaac, J.H., Lancaster, J.G.: A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacement. Proc. Inst. Mech. Eng. 214 (H), 39–47 (2000)

    Google Scholar 

  20. Zum Gahr, K.H.: Microstructure and Wear of Materials. Elsevier, The Netherlands (1987)

    Google Scholar 

  21. Liu Y., Timmers, H.: Possible lubrication and temperature effects in the micro-scratching of polyethylene terephthalate (PET). In: 35th Annual Condensed Matter and Materials Meeting (2011)

  22. Sinha, S.K., Chong, W.L.M., Lim, S.C.: Scratching of polymers—modeling abrasive wear. Wear. 262, 1038–1047 (2006)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yanyan Liu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Liu, Y., Warner, J.A., Gladkis, L.G. et al. Microscratching Characterization of the Wear-in of UHMW Polyethylene in Prostheses. Tribol Lett 49, 439–450 (2013). https://doi.org/10.1007/s11249-012-0087-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11249-012-0087-5

Keywords

Navigation