Skip to main content
Log in

Explosive Contamination from Substrate Surfaces: Differences and Similarities in Contamination Techniques Using RDX and C-4

  • Original Paper
  • Published:
Sensing and Imaging: An International Journal Aims and scope Submit manuscript

Abstract

Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that found on canvas or denim, suede leather such as might be found on jackets, purses, or shoes, and painted metal obtained from a car hood at a junk yard. The samples were not pre-cleaned prior to testing and contained sizing agents, and in the case of the metal, oil and dirt. The substrates were photographed using a Zeiss Discover V12 stereoscope with Axiocam ICc1 3 megapixel digital camera to determine the difference in the crystalline structure and surface contamination in an attempt to determine differences and similarities associated with current contamination deposition techniques. Some samples were analyzed using scanning electron microscopy (SEM) and some were extracted and analyzed with high performance liquid chromatography (HPLC) or gas chromatography with an electron capture detector (GC-ECD) to quantify the data.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Beveridge, A. (1998). Forensic investigation of exposions (pp. 65–69). Pennsylvania: Taylor and Francis, LTD.

    Google Scholar 

  2. Elias, L. (1995). NRC Procedures for laboratory evaluation of trace explosive detectors. In Proceeding of the third workshop of the international civil aviation organization (ICAO) Ad Hoc Grop of specialists in the detection of explosives. Federal Aviation Administration, William J. Hughes Technical Center, Aviation Security Laboratory, Atlantic City International Airport, NJ 16–19 Oct 1995.

  3. Fox, F. T., Sisk, S., DiBartolo, R., Greeen, D. A., & Miller, J. F. (1995). Preparation and characterization of plastic explosive suspensions as analogs of fingerprint derived contaminants for use in certification of explosives detection system. In Proceedings of the 5th international symposium on the analysis and detection of explosives, 4–8 Dec 1995, Washington, DC.

  4. Chamberlain, R. T. Dry transfer method for the preparation of explosives test samples, United States Patent 6470730.

  5. Gillen, G., Fletcher, R., Verkoutern, J., Verkouteren, M., Zeissler, C., Klouds, G., Benner, B., Santiago, M., and Evans, A. Advanced inkjet printing technology for trace explosive standards. http://www.cstl.nist.gov/div837/Division/Outputs/Explosives/ISADEinkjettalk.pdf.

  6. Gresham, G. L., Davies, J. P., Goodrich, L. D, Blackwood, L. G., Liu, B. Y., Thimsem, D., Yoo, S. H. & Hallowell, S. F. (1994). Development of particle standards for testing detection systems: Mass of RDX and particle size distribution of composition 4 residues. In Proceedings of SPIE, vol 2276, p. 34.

  7. Carmack, W. J. & Hembree, P. B. (1998). Particle size analysis of prepared solutions and fingerprint deposits of high explosive materials. INEEL/EXT-97-01202, April 1998.

  8. Hallowell, S. F. (2001). Screening people for illicit substances: A survey of current portal technology. Talanta, 54, 447–458.

    Article  Google Scholar 

  9. Verkouteren, J. R. (2007). Particle characteristics of trace high explosives: RDX and PETN. Journal of Forensic Science, 52(2), 335–340.

    Article  Google Scholar 

  10. Settles, G. S., Ferree, H. C. Tronosky, M. D., & Moyer, Z. M. Natural aerodynamic portal sampling of trace explosives from the human body. http://www.me.psu.edu/psgdl/Settles_TraceDetex_paper.pdf.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. J. Miller.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miller, C.J., Yoder, T.S. Explosive Contamination from Substrate Surfaces: Differences and Similarities in Contamination Techniques Using RDX and C-4. Sens Imaging 11, 77–87 (2010). https://doi.org/10.1007/s11220-010-0053-y

Download citation

  • Received:

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11220-010-0053-y

Keywords

Navigation