Causes of the deformation of a building in Magadan are examined. It is established that the cause of crack formation in the administrative building is loss of strength by brick masonry as a result of waterlogging of the lower section of the wall due to entry of atmospheric moisture and ground water of the seasonally thawing layer through the poorly protected socle and rubble-concrete foundation, which is devoid of waterproofing.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Translated from Osnovaniya, Fundamenty i Mekhanika Gruntov, No. 4, pp. 28-31, July-August, 2009.
Rights and permissions
About this article
Cite this article
Vlasov, V.P. Causes of deformations and crack formation in an administrative building in Magadan. Soil Mech Found Eng 46, 158–162 (2009). https://doi.org/10.1007/s11204-009-9058-8