Abstract
A reliable reversed-phase high-performance liquid chromatographic method has been developed for analysis of related impurities in industrial phthalic anhydride (PA). Maleic acid (hydrolysis product of maleic anhydride), phthalimide, and benzoic acid were separated from phthalic acid (Pa, hydrolysis product of PA) on a C18 column by gradient elution with acetonitrile and 0.1% (v/v) aqueous perchloric acid solution. This method is simple, sensitive, and accurate, and has been successfully applied to quality control of PA for industrial use.
Similar content being viewed by others
References
X.D. Zhang, P.D. Siegel, D.M. Lewis, Int. Immunopharmacol. 2, 239 (2002). doi:10.1016/S1567-5769(01)00176-X
C. Fumagalli, G. Golinelli, G. Mazzoni, M. Messori, G. Stefani, F. Trifiro, Catal. Lett. 21, 19 (1993). doi:10.1007/BF00767366
M.C. Cucarell, F. Crespo, J. Gas Chromatogr. 6, 39 (1968)
N.R. Foste, M.S. Wainwright, Chromatographia 11, 19 (1978). doi:10.1007/BF02262948
M.S. Wainwright, T.W. Hoffman, J. Chromatogr. Sci. 14, 159 (1976)
M.S. Wainwright, R.P. Chaplin, F. Leonardi, Chromatographia 20, 96 (1985). doi:10.1007/BF02280604
B. Rietz, Anal. Lett. 18, 1193 (1985)
M.P. Gimeno, J. Gascon, C. Tellez, J. Herguido, M. Menendez, Chem. Eng. Process 47, 1844 (2008). doi:10.1016/j.cep.2007.10.010
A.I. Anastasov, Chem. Eng. J. 109, 57 (2005). doi:10.1016/j.cej.2005.03.010
A.I. Anastasov, Chem. Eng. Process 42, 449 (2003). doi:10.1016/S0255-2701(02)00063-6
H.Z. Lian, Y.N. Wei, Talanta 71, 264 (2007). doi:10.1016/j.talanta.2006.03.054
F.J. Healy, H.P. Dengler, United States Patent 005214157A, 1993
C.A. Bunton, N.A. Fuller, S.G. Perry, V.J. Shiner, J. Chem. Soc. 2918 (1963). doi:10.1039/JR9630002918
J.M. Rosenfelda, C.B. Murphy, Talanta 14, 91 (1967). doi:10.1016/0039-9140(67)80050-X
H.Z. Lian, L. Mao, X.L. Ye, J. Miao, J. Pharm. Biomed. Anal. 19, 621 (1999). doi:10.1016/S0731-7085(98)00101-0
ISO, Guide to the expression of uncertainty in measurement (ISO, 1995)
EURACHEM/CITAC, Quantifying uncertainty in analytical measurement, 2nd edn. (EURACHEM, 2000). http://www.measurementuncertainty.org/mu/guide/
Acknowledgments
This work was supported by the National Basic Research Program of China (973 program, 2009CB421601, 2011CB911003), the National Natural Science Foundation of China (20575027, 90913012), the National Science Funds for Creative Research Groups (20821063), and the Analysis and Test Fund of Nanjing University.
Author information
Authors and Affiliations
Corresponding authors
Rights and permissions
About this article
Cite this article
Zhou, Lf., Qiao, Jq., Lian, Hz. et al. An example of quality control of fine chemical intermediates: related impurity analysis of industrial phthalic anhydride by reversed-phase high-performance liquid chromatography. Res Chem Intermed 37, 617–625 (2011). https://doi.org/10.1007/s11164-010-0234-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11164-010-0234-2