Device for comparative evaluation of the heat resistance of ceramic specimens by recording acoustic emission

  • Published:
Refractories and Industrial Ceramics Aims and scope

A device is described for comparative evaluation of the thermal shock resistance of ceramic specimens of identical shape and dimensions by recording acoustic emission (AE) pulses during air cooling from 1000C. The number of AE pulses in a unit of time, whose intensity exceeds the 10% level of maximum signal intensity, is used as a comparative characteristic for thermal shock resistance of ceramic materials. Comparison of the AE pulse distribution with respect to amplitude contains additional information about the thermal shock resistance of comparable specimens. With use of high-temperature furnaces with a considerable working volume and treatment of repeated cooling conditions the measurement part of the device may be used for evaluating the comparative thermal shock resistance of ceramic specimens and objects of any shape and size during cooling from above 1000°C.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. K. K. Strelov, Structure and Properties of Refractories [in Russian], Metallurgiya, Moscow (1982).

    Google Scholar 

  2. V. A. Greshnikov and Yu. B. Drobot, Acoustic Emission [in Russian], Izd. Standartov, Moscow (1976).

    Google Scholar 

  3. I. P. Tsibin, Yu. M. Rapoport, A. T. Kuznetsov, et al., “Study of thermal destruction of refractories with use of an acoustic emission method,” Ogneupory, No. 7, 15–20 (1984).

  4. G. A. Gogotsi, A. V. Drozdov, and N. N. Radin, “Automated system for studying the thermal shock resistance of ceramic and refractory materials,” Probl. Prochn., No. 6, 11–113 (1984).

    Google Scholar 

  5. A. A. Frolov, “Ceramic materials for preparation of high purity compounds of niobium and tantalum,” Steklo Keramika, No. 7, 14–15 (1992).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Novye Ogneupory, No. 5 pp. 44–47, May 2009.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Voinich, E.V., Frolov, A.A. Device for comparative evaluation of the heat resistance of ceramic specimens by recording acoustic emission. Refract Ind Ceram 50, 204–207 (2009). https://doi.org/10.1007/s11148-009-9169-9

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11148-009-9169-9

Keywords

Navigation