Abstract
We briefly describe equipment and methods for a study of the influence of deep cooling on the parameters of sensors of millimeter-wave receivers, which are not designed for operation under such conditions, and present the data on improvement of their sensitivity and the ranges of optimal temperatures.
Similar content being viewed by others
References
V. I. Krivoruchko, Radiophys. Quantum Electron., 46, Nos. 8–9, 703 (2003).
V. I. Krivoruchko, in: Proc. Anniversary Scientific and Technical Conference of the Federal State Unitary Enterprise “TsNIRTI,” Moscow, May 2230, 2003, p. 58.
V. G. Bozhkov, V. F. Vdovin, V. N. Voronov, et al., Radiotekh. Elektron., 42, No. 4, 736 (1993).
V. G. Bozhkov, V. A. Genneberg, V. N. Romanovskaya, L. I. Fedoseev, et al., J. Commun. Technol. Electron., 41, No. 9, 818 (1996).
V. G. Bozhkov, V. A. Genneberg, L. M. Koukin, and L. I. Fedoseev, Radiophys. Quantum Electron., 43, No. 8, 658 (2000).
V. G. Bozhkov, V. A. Genneberg, K. I. Kurkan, and V. I. Perfil’ev, Elektron. Prom., No. 5, 77 (2001).
Author information
Authors and Affiliations
Additional information
__________
Translated from Izvestiya Vysshikh Uchebnykh Zavedenii, Radiofizika, Vol. 48, No. 10–11, pp. 863–868, October–November 2005.
Rights and permissions
About this article
Cite this article
Vdovin, V.F., Korotaev, D.V., Krivoruchko, V.I. et al. Study of the influence of cooling on the parameters of millimeter-wave high-frequency amplifiers, mixers, and mixer-amplifier modules of industrial manufacturing. Radiophys Quantum Electron 48, 767–771 (2005). https://doi.org/10.1007/s11141-006-0006-4
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s11141-006-0006-4