Amethod for measuring the mean molecular weight of dextrans by diffusion-ordered NMR spectroscopy was developed and validated. This method allows measurements of dextran self-diffusion coefficients to determine their mean molecular weight. The linearity, correctness, similarity, intralaboratory precision, and specificity of the method were evaluated. “Added/found” ratios for different dextrans were used to determine the standard deviations, coefficients of variation, significance intervals, systematic errors, Fisher’s F test, and Student’s t test for measurements of mean molecular weight. These statistical characteristics satisfied the criteria for validation parameters in the Russian and foreign normative documentation.
Similar content being viewed by others
Notes
Mp is the peak MW on measurement of mean MW. Mw is the weight average MW of the polymer. Mn is the number average MW of the polymer.
Ds is the mean self-diffusion coefficient. Dp is the peak self-diffusion coefficient on the distribution plot.
References
I. N. Gogotov, Proceedings of the International Scientific-Applied Conference “Perspectives and Problems in the Development of Biotechnology in the Framework of the Common Economic Space of the Commonwealth Countries” [in Russian], Minsk-Naroch (2005), pp. 54 – 55.
N. E. Kuz’mina, S. V. Moiseev, V. I. Krylov, et al., Zh. Analit. Khimii, 69(10), 1047 – 1053 (2014); N. E. Kuz’mina, S. V. Moiseev, V. I. Krylov, et al., Rus. J. Anal. Chem., 69(10), 953 – 959 (2014).
S. V. Moiseev, N. E. Kuz’mina, V. I. Krylov, et al., Vedomosti NTsÉMP, 2, 9 – 15, (2014).
S. W. Provencher, J. Chem. Phys., 64(7), 2772 – 2777 (1976).
N. V. Yurgel’ (red.), Guidelines for the Validation of Methods for the Analysis of Medicines (Methodological Guidelines), Sport i Kul’tura-2000, Moscow (2007).
V. V. Beregovykh (ed.), Validation of Analytical Methods for Drug Manufacturers. Model Guidelines for Businesses Making Drugs [in Russian], Literra, Moscow (2008).
General Pharmacopeia Monograph OFS 1.1.0012.15 Validation of Analytical Methods, State Pharmacopeia of the Russian Federation, XIII ed., Vol. 1, Moscow (2015).
A WHO Guide to Good Manufacturing Practice (GMP) Requirements, Part 2, Validation, WHO / VSQ / 97.02, Geneva (1999).
Recommended International Guidelines RMG 61 – 2003 GSI, Measures of the Accuracy, Correctness, and Precision of Quantitative Chemical Analysis Methods. Methods of Assessment [in Russian], Standards Press, Moscow (2004).
State Standard GOST R ISO 5725-2-2002, Accuracy (Correctness and Precision) of Measurement Methods and Results [in Russian], Standards Press, Moscow (2004). Part 2, A Basic Method for Determining Repeatability and Reproducibility of a Standard Method of Measurement.
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Khimiko-Farmatsevticheskii Zhurnal, Vol. 51, No. 9, pp. 60 – 63, September, 2017.
Rights and permissions
About this article
Cite this article
Moiseev, S.V., Kuz’mina, N.E., Krylov, V.I. et al. Validation of a Method of Measuring Mean Molecular Weight of Dextrans by Diffusion-Ordered Spectroscopy. Pharm Chem J 51, 829–832 (2017). https://doi.org/10.1007/s11094-017-1701-5
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11094-017-1701-5