Design and development of optical fiber Bragg grating based device for measurement of handgrip force

  • Published:
Optical and Quantum Electronics Aims and scope Submit manuscript

Abstract

A non-invasive optical fiber Bragg grating based handgrip device for the dynamic measurement of the handgrip force is proposed. The handgrip force is an indicator of biomechanical parameters like fracture of vertebral bones, limb strength, etc. The proposed device converts the grip force exerted at the surface into strain variation on the vertical bars, which is sensed by the bonded fiber Bragg grating sensors. Ansys Multiphysics is used for modeling and analysis of the handgrip device. The developed device is calibrated using a micro universal testing machine (μUTM) to determine the relationship between the load/force applied on the device and the Bragg wavelength shift of the fiber Bragg grating sensor and a calibration factor of 5.35 µϵ/Kg is obtained. The device shows a sensitivity of 1.21 pm/μϵ. The developed device is used to measure the handgrip force of a subject with a fractured arm. 10 volunteers (both men and women) with fractured arms were involved in the study. Additionally, the fiber Bragg grating based handgrip device is clinically evaluated in comparison to an X-ray image. The radiations due to X-rays harm the healthy tissues, concerning this developed device offers benefits such as being immune to electromagnetic interference, small size, lightweight, highly sensitive and applicable for a variation in the force exerted by the handgrip, aiding in monitoring the rehabilitation of patients with arm injuries.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

Availability of data and materials

Available on demand.

References

  • Ambastha, S., Umesh, S., Dabir, S., Asokan, S.: Spinal needle monitoring during lumbar puncture using fiber Bragg grating force device. J. Biomed. Opt. 21, 117002–117006 (2016)

    Article  ADS  Google Scholar 

  • Babatunde, O.M., Fragomen, A.T., Rozbruch, S.R.: Noninvasive quantitative assessment of bone healing after distraction osteogenesis. HSS J. 6, 71–78 (2010)

    Article  Google Scholar 

  • Black, R.J., Zare, D., Oblea, L., Park, Y.L., Moslehi, B., Neslen, C.: On the gage factor for optical fiber grating strain gages. Int. SAMPE Symp. Exhib. 8, 18–22 (2008)

    Google Scholar 

  • Bohannon, R.W.: Method a −percept. Mot. Skills. 93, 323–328 (2001)

    Article  Google Scholar 

  • Campanella, C.E., Cuccovillo, A., Campanella, C., Yurt, A., Passaro, V.M.N.: Fibre Bragg Grating based strain sensors Review of technology and applications. Sensors 18, 3115 (2018)

    Article  ADS  Google Scholar 

  • Chethana, K., Prasad, A.G., Ravi, M., Omkar, S.N., Asokan, S.: Fiber Bragg grating sensor based device for the measurement of hand grip strength. JETIR 6, 1–14 (2019)

    Google Scholar 

  • Chethana, K., Honnungar, R.V., Ibrar Jahan, M.A., Asokan.: Comparison studies on hand grip measurement techniques using FBG sensor and sEMG. In: Proceedings of CONECCT 2020—6th IEEE Int. Conf. Electron. Comput. Commun. Technol. 4–8 (2020)

  • Chethana, K., Honnungar, R.V., Ibrar Jahan, M.A., Guruprasad, A.S., Asokan.: Design and calibration of Fiber Bragg Grating sensor for analysis of real time wrist angular grip strength. Mater. Today Proc. (2021). https://doi.org/10.1016/j.matpr.2020.10.471

  • Cruz-Jentoft, A.J., et al.: Sarcopenia European consensus on definition and diagnosis. Age Age. 39, 412–423 (2010)

    Article  Google Scholar 

  • Hill, K.O., Meltz, G.: Fiber Bragg grating technology fundamentals and overview. J. Light. Technol. 15, 1263–1276 (1997)

    Article  ADS  Google Scholar 

  • Kalfas, I.H.: Principles of bone healing. Neurosurg. Focus. 10, 1–4 (2001)

    Article  Google Scholar 

  • Kumar, G., Narayan, B.: The biology of fracture healing in long bones. Class. Pap. Orthop. 60, 531–533 (2014)

    Article  Google Scholar 

  • Li, K., Hewson, D.J., Duchêne, J., Hogrel, J.Y.: Predicting maximal grip strength using hand circumference Man. Ther. 15, 579–585 (2010)

    Google Scholar 

  • Marsell, R., Einhorn, T.A.: The biology of fracture healing. Injury 42, 551–555 (2011)

    Article  Google Scholar 

  • Massaroni, C., Zaltieri, M., Presti, L., Nicolò, A., Tosi, D., Schena, E.: Fiber Bragg grating sensors for cardiorespiratory monitoring: a review. IEEE Sens. J. 20, 1–12 (2020)

    Article  Google Scholar 

  • Mihailov, S.J.: Fiber Bragg grating sensors for harsh environments. Sensors. 12, 1898–1918 (2012)

    Article  ADS  Google Scholar 

  • Mühldorfer-Fodor, M., et al.: Grip force monitoring on the hand: manugraphy system versus Jamar dynamometer. Arch. Orthop. Trauma Surg. 134, 1179–1188 (2014)

    Article  Google Scholar 

  • Nicholson, J.A., Tsang, S.T.J., MacGillivray, T.J., Perks, F., Simpson, A.H.R.W.: What is the role of ultrasound in fracture management? Bone Jt. Res. 8, 304–312 (2019)

    Article  Google Scholar 

  • Nicolay, C.W., Walker, A.L.: Grip strength and endurance influences of anthropometric variation, hand dominance, and gender. Int. J. Ind. Ergon. 35, 605–618 (2005)

    Article  Google Scholar 

  • Norman, K., Schütz, T., Kemps, M., Lübke, H.J., Lochs, H., Pirlich, M.: The subjective global assessment reliably identifies malnutrition-related muscle dysfunction. Clin. Nutr. 24, 143–150 (2005)

    Article  Google Scholar 

  • Othonos, A.: Fiber Bragg gratings. Rev. Sci. Instrum. 68, 4309–4341 (1997)

    Article  ADS  Google Scholar 

  • Paul, J., Zhao, L., Ngoi, B.K.A.: Fiber-optic sensor for handgrip-strength monitoring: conception and design. Appl. Opt. 44, 3696–3704 (2005)

    Article  ADS  Google Scholar 

  • Presti, D.L., et al.: Fiber Bragg gratings for medical applications and future challenges a review. IEEE Access 8, 156863–156888 (2020)

    Article  Google Scholar 

  • Shefelbine, S.J., et al.: Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis. Bone 36, 480–488 (2005)

    Article  Google Scholar 

  • Trinidad Fernandez, M., et al.: Muscle activity and architecture as a predictor of handgrip strength. Physiol. Meas. 41, 0–30 (2017)

    Google Scholar 

  • Vermeulen, J., Neyens, J.C.L., Spreeuwenberg, M.D., Van Rossum, E., Hewson, D.J., De Witte, L.P.: Measuring grip strength in older adults Comparing the grip-ball with the Jamar dynamometer. J. Geriatr. Phys. Ther. 38, 148–153 (2015)

    Article  Google Scholar 

  • Vigneswari, S.V., Savithri, D., Mahendran, V.S.: Gripping force measurement and EMG classification for hand functions. Int. J. Appl. Eng. Res. 10, 17315–17326 (2015)

    Google Scholar 

  • Wall, B.F., Kendall, G.M., Edwards, A.A., Bouffler, S., Muirhead, C.R., Meara, J.R.: What are the risks from medical X-rays and other low dose radiation? Br. J. Radiol. 79, 285–294 (2006)

    Article  Google Scholar 

  • Wolynski, J.G., et al.: Utilizing multiple BioMEMS sensors to monitor orthopaedic strain and predict bone fracture healing. J. Orthop. Res. 37, 1873–1880 (2019)

    Article  Google Scholar 

  • Wong, L.C.Y., Chiu, W.K., Russ, M., Liew, S.: Review of techniques for monitoring the healing fracture of bones for implementation in an internally fixated pelvis. Med. Eng. Phys. 34, 140–152 (2012)

    Article  Google Scholar 

Download references

Acknowledgements

We thank Prof Asokan S, Dept of Applied Physics & Instrumentation and Prof T Srinivas, Applied Photonics Lab, Indian Institute of Science, Bengaluru for providing the laboratory to do simulations and experiments.

Author information

Authors and Affiliations

Authors

Contributions

Ibrar Jahan M A—Conceptualization, Simulation, Methodology and Writing original draft preparation. Chethana K—Conceptualization, Methodology and Reviewing. Rajini V Honnungar—Conceptualization, Supervision, Reviewing and Editing. S Asokan—Conceptualization, Supervision.

Corresponding author

Correspondence to M. A. Ibrar Jahan.

Ethics declarations

Conflict of interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Consent for publication

All authors have agreed and have given their consent for the publication of this research paper.

Research involving human participants

Approval was obtained from the Human Ethics Committee (HEC) of the Indian Institute of Science, Bengaluru and all the volunteers involved in the study gave their consent.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jahan, M.A.I., Chethana, K., Honnungar, R.V. et al. Design and development of optical fiber Bragg grating based device for measurement of handgrip force. Opt Quant Electron 54, 68 (2022). https://doi.org/10.1007/s11082-021-03429-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s11082-021-03429-2

Keywords

Navigation