Skip to main content
Log in

The effect of spot size on linearity improvement of tetra-lateral position sensitive detector

  • Published:
Optical and Quantum Electronics Aims and scope Submit manuscript

Abstract

Linearity improvement of tetra-lateral position sensitive detector (PSD) is highly desired in many applications where accurate measurements of the PSD are required. The effect of beam size on our newly proposed linearity improvement scheme is discussed in this paper. Theoretical studies on the electrical potential and collected photocurrents are presented to simplify the numerical calculation when the beam size of the spot is considered. Simulation results show that our new formula can still give a nearly perfect linearity and measurement accuracy even if the spot has a considerable beam size.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Connors W.P.: Lateral photodetector operating in the fully reverse-biased mode. IEEE Trans. Electron Devices 18, 591–596 (1971)

    Article  Google Scholar 

  • Cui S., Soh Y.C.: Improved measurement accuracy of the quadrant detector through improvement of linearity index. Appl. Phys. Lett 96, 081102 (2010a)

    Article  ADS  Google Scholar 

  • Cui S., Soh Y.C.: Linearity indices and linearity improvement of 2-D tetra-lateral position sensitive detector. IEEE Trans. Electron Devices 57, 2310–2316 (2010b)

    Article  ADS  Google Scholar 

  • Cui S., Soh Y.C.: Convergent conductivity corrections to the Casimir force via exponential basis functions. Phys. Rev. A 82, 062510 (2010c)

    Article  ADS  Google Scholar 

  • Haberman R.: Elementary Applied Partial Differential Equations: With Fourier Series and Boundary Value Problems. Prentice-Hall, Englewood Cliffs (1987)

    Google Scholar 

  • Huang M.Z., Shi L.Z., Wang Y.X., Ni Y., li Z.Q., Ding H.F.: Development of a new signal processor for a tetralateral position sensitive detector based on single-chip microcomputer. Rev. Sci. Instrum 77, 083301 (2006)

    Article  ADS  Google Scholar 

  • Lucovsky G.: Photoeffects in nonuniformly irradiated p-n junctions. J. Appl. Phys 31, 1088–1095 (1960)

    Article  ADS  Google Scholar 

  • MacLachlan R.A., Riviere C.N.: High-speed microscale optical tracking using digital frequency-domain multiplexing. IEEE Trans. Instrum. Meas. 58, 1991–2001 (2009)

    Article  Google Scholar 

  • Position-Sensitive Detectors, Hamamatsu Photonics K.K., Solid State Division, Product Catalog (1987)

  • Prudnikov A.P., Brychkov Y.A., Marichev O.I.: Integrals and Series. Volume 2: Special Functions. Gordon and Breach Science, London (1986)

    Google Scholar 

  • Wang W., Busch-Vishniac I.J.: The linearity and sensitivity of lateral effect position sensitive devices—an improved geometry. IEEE Trans. Electron Devices 36, 2475–2480 (1989)

    Article  ADS  Google Scholar 

  • Woltring H.J.: Single- and dual-axis lateral photodetectors of rectangular shape. IEEE Trans. Electron Devices 22, 581–586 (1975)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yeng Chai Soh.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cui, S., Soh, Y.C. The effect of spot size on linearity improvement of tetra-lateral position sensitive detector. Opt Quant Electron 42, 721–728 (2011). https://doi.org/10.1007/s11082-011-9462-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11082-011-9462-y

Keywords

Navigation