A novel approach for non-invasive measurement of mean arterial pressure using pulse transit time

  • Published:
Multimedia Tools and Applications Aims and scope Submit manuscript

Abstract

Recent days many researches are carried out related to the heart of the human. As a result many remedies are found for the various heart disorders. Electrocardiography (ECG) is the exertion of the electrical response from heart by placing the electrodes over the chest. The Einthoven triangle is an imaginary formation of the three leads in the triangle used in electrocardiography; by that technique of placement of electrode we can analysis the electrocardiogram of the heart. The waveform is also known as PQR waveform which contains the information of arterial repolarization, arterial polarization, ventricular repolarization and ventricular polarization. In general the BP monitor is carried out using oscillometry. In the existing system separate techniques and devices are used to measure electrocardiography and BP. The proposed system is to integrate both electrocardiography and blood pressure measurement by means adopting transit pulse time. It is defined as the systematic time lay off betwixt oscillometric pulses and peaks of ECG especially R peaks of it. The major advantage of the system is to exhibit non-zero crossing and gives more accurate result. The mean arterial pressure estimation is done by using MatLab which is the unique estimation method for measuring pulse transit time interval. Thus the non invasive system designed which reduce the cuff deviations and errors in electrocardiography. It can be applied in detecting the arterial disorders at most efficient manner.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Ahmed S et al. (2012) Electrocardiogram assisted blood pressure estimation. IEEE Trans Biomed Eng 59

  2. Amoore JN et al (2008) Automatic blood pressure measurement: the Oscillometric waveform shape is a potential contributor to differences between Oscillometric and Auscultatory pressure measurements. J Hypertension 26(1):35–43

    Article  Google Scholar 

  3. Baktin I, Ahmad S, Bolic M, Groza VZ, Dajani HR, Forouzanfar M (2012) Apparatus and methods for ECG assisted blood pressure measurement. U.S. Patent

  4. Balasingam B, Forouzanfar M, Bolic M, Rajan S (2011) Arterial blood press parameter estimation and tracking using particle filters. Proc IEEE Int Workshop Med Meas Appl

  5. De La O Serna JA (2013) Taylor–fourier analysis of blood pressure oscillometric waveforms. IEEE Trans Instrument Meas 62(9):2511–2518

    Article  Google Scholar 

  6. Dhanalakshmi K, Rajamani V (2013) An intelligent mining system for diagnosing medical images using combined texture-histogram features. Int J Imaging Syst Technol 23(2):194–203

    Article  Google Scholar 

  7. Dhiravidachelvi E, Rajamani V (2015) A novel approach for diagnosing diabetic retinopathy in fundus images. J Comput Sci 11(1):262

    Article  Google Scholar 

  8. Forouzanfar M, Ahmad S, Batkin I, Dajani HR, Grozaand VZ, Bolic M (2012) Coefficient-free blood pressure estimation based on pulse transit time–cuff pressure dependence

  9. Forouzanfar M et al. (2014) Ratio- independent blood pressure estimation by modeling the oscillometric waveform envelope. IEEE Trans Instrument Meas 63

  10. Frouzanfar M, Ahmed S, Baktin I, Dajani HR, Groza VZ (2013) Coefficient free blood press estimation based on pulse transit time cuff pressure dependence 60

  11. Karthikeyan A, Kumar PS (2017) GALS implementation of randomly prioritized buffer-less routing architecture for 3D NoC. Clust Comput. https://doi.org/10.1007/s10586-017-0979-0

  12. Karthikeyan A, Senthil Kumar P (2017) Randomly prioritized buffer-less routing architecture for 3D network on Chip. Comput Electr Eng 59:39–50, ISSN 0045-7906. https://doi.org/10.1016/j.compeleceng.2017.03.006

    Article  Google Scholar 

  13. de la O Serna JA, Van Moer W, Barbe K (2013) Using alternating Kalman filtering to analyze Oscillometric blood pressure waveforms. IEEE Trans Instrum Meas 62(10):2621–2628

    Article  Google Scholar 

  14. Lee S et al (2013) Oscillometric blood pressure estimation based on maximum amplitude algorithm employing Gaussian mixture regression. IEEE Trans Instrument Meas 62(12):3387–3389

    Article  Google Scholar 

  15. Lin C-T, Liu S-H, Wang J-J, Wen Z-C (2003) Reduction of interference in oscillometric arterial blood press measurement using fuzzy logic. IEEE Trans Biomed Eng 50(4)

  16. Mafi M, Rajan S, Bolic M, Dajani HR (2011) Blood pressure estimation using oscillometric pulse morphology. Proc Annual International Conference, IEEE Eng Med Biol Soc USA

  17. Nichols W, O’Rourke M (2005) Eds. McDonald’s . Blood flow in arteries: Theoretical, experimental and clinical principles, 5th Edition. Bel Air, CA, USA: Hodder Arnold Publishers

  18. Nitzan M (2011) Automatic noninvasive measurement of arterial blood pressure. IEEE Instrum Meas Mag 14(1):32–37

    Article  Google Scholar 

  19. Prabhu V, Gunasekaran G (2016) Fuzzy logic based NAM speech recognition for Tamil syllables. Indian J Sci Technol 9(1). doi:https://doi.org/10.17485/ijst/2016/v9i1/85763

  20. Prabhu V, Kuppusamy PG, Karthikeyan A, Varatharajan R (2018) Evaluation and analysis of data driven in expectation maximization segmentation through various initialization techniques in medical images. Multimed Tools Appl. https://doi.org/10.1007/s11042-018-5792-0

  21. Ramaat R, Tailts J, Jakomagi K (2010) Mathematical modeling of non-invasive Oscillometric finger mean blood pressure measurement by maximum oscillation criterion. Med Biol Eng Comput 37

  22. Song SH, Kim DK, Lee JS (2009) Mean arterial pressure estimation method using morphological changes in oscillometric waveform. Proc IEEE Conf Comput Cardiol USA

  23. Van Montfrans GA (2001) Oscillometric blood press measurement: progress and problems. Blood Press Monitor 6(6):287–290

    Article  Google Scholar 

  24. Zheng D, Amoore JN (2011) Estimation of mean arterial pressure from oscillometric cuff pressure: comparison of different techniques. Med Biol Eng Comput Cardiol

  25. Zheng D, Murray A (2008) Estimation of mean blood pressure from Oscillometric and manual methods. Proc IEEE Conf Comput Cardiol Bologan, Italy: 941–944

  26. Zheng L et al (2008) Pulse pressure and mean arterial pressure in relation to ischemic stroke among patients with uncontrolled hypertension in rural areas of China. Stroke 39(7):1932–1937

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. Prabhu.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Prabhu, V., Kuppusamy, P.G., Karthikeyan, A. et al. A novel approach for non-invasive measurement of mean arterial pressure using pulse transit time. Multimed Tools Appl 79, 3775–3789 (2020). https://doi.org/10.1007/s11042-018-6971-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11042-018-6971-8

Keywords

Navigation