Results of the Coomet 646/Ru/14 Pilot Comparison of National Standards of the Unit of Sound Oscillation Velocity of Water Particles

  • INTERNATIONAL COLLABORATION
  • Published:
Measurement Techniques Aims and scope

We present the results of comparison of national standards of the units of sound oscillation velocity of water particles within the range from 5 Hz to 10 kHz performed by the Hangzhou Applied Acoustics Research Institute (Pilot Laboratory) and the All-Russia Research Institute of Physicotechnical and Radio Measurements (VNIIFTRI) (COOMET 646/RU/14 Pilot Comparisons). The calibration capabilities of the participants were evaluated according to the results of measurements of the sensitivity of oscillation-velocity receivers: KGP-10, VHS56, and VHS90. At frequencies varying from 5 Hz to 500 Hz, inclusively, the calibrations were performed in a chamber as a result of comparison with a reference hydrophone performed by the method of oscillating water column. At frequencies higher than 500 Hz, we used the measuring procedure of the reciprocity method in the free field of traveling spherical sound waves. No significant inconsistencies in the calibration results were discovered at any frequency used for comparisons. The maximal discrepancies between the values of sensitivity obtained by the participants did not exceed 1.2 dB.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.

Similar content being viewed by others

References

  1. V. A. Gordienko, Vector-Phase Methods in Acoustics, Fizmatlit, Moscow (2007).

    Google Scholar 

  2. V. E. Ivanov and V. A. Kirshov, “Calibration of vector acoustic receivers,” Izmer. Tekhn., No. 9, 61–64 (1981).

    Google Scholar 

  3. A. E. Isaev, A. N. Matveev, G. S. Nekrich, and S. V. Sil’vestrov, “Standard installations for the reproduction and transfer of the unit of oscillation velocity of water medium within the frequency range from 5 to 10000 Hz,” Vestn. Metrol., No. 1, 14–20 (2007).

  4. A. E. Isaev, A. N. Matveev, G. S. Nekrich, and A. M. Polikarpov, “Complex calibration of the receiver of pressure gradient with the use of the procedure of reciprocity method,” Akust. Zh., 60, No. 1, 48–55 (2014).

    Google Scholar 

  5. IEC 60565(2006), Underwater Acoustics. Hydrophones. Calibration in the Frequency Range from 0.01 Hz to 1 MHz.

  6. A. E. Isaev and A. N. Matveev, “Calibration of hydrophones according to a field in the case of permanent emission in reverberating basins,” Akust. Zh., 55, No. 6, 727–736 (2009).

    Google Scholar 

  7. A. E. Isaev, Precise Calibration of the Receivers of Sound Pressure in Water Media under the Free-Field Conditions, VNIIFTRI, Mendeleevo (2008).

    Google Scholar 

  8. GOST 34100.3–2017/ISO/IEC Guide 98-3:2008, Uncertainty of Measurements. Part 3. Guide to the Expression of Uncertainty in Measurement.

  9. COOMET R/GM/11:2017, Recommendations of COOMET. Regulations of the Comparisons of Standards for the National Metrological Institutes of COOMET, www.coomet.org/DB/isapi/cmt_docs/2017/06/01F711415.pdf, acc. 04.14.2019.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. E. Isaev.

Additional information

Translated from Izmeritel’naya Tekhnika, No. 7, pp. 67–72, July, 2019.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Isaev, A.E., Matveev, A.N., Nekrich, G.S. et al. Results of the Coomet 646/Ru/14 Pilot Comparison of National Standards of the Unit of Sound Oscillation Velocity of Water Particles. Meas Tech 62, 651–658 (2019). https://doi.org/10.1007/s11018-019-01674-2

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11018-019-01674-2

Keywords

Navigation