The a posteriori reliability of verification of measurement instrumentation under conditions of unequal measurement accuracy of tolerance monitoring systems is calculated and a computer program is used to estimate it.
Similar content being viewed by others
References
S. F. Levin, “Support for the uniformity of measurements during verification of means of measurement,” Izmer. Tekhn., No. 8, 14–18 (2005).
MI 2916–2005, GSI. Identification of Probability Distributions for Solving Measurement Problems.
MI 1317–2004, GSI. Results and Characteristics of Measurement Errors. Forms of Representation. Methods for Their Use in Tests of Production Samples and Monitoring Their Parameters.
RMG 29–2013, GSI. Metrology. Basic Terminology and Definitions.
MI 187–86, MU GSI. Means of Measurement. Tests for Reliability and Parameters for Verification Methods.
GOST R ISO/IEC 17025–2009, General Specifications for Competence of Test and Calibration Laboratories.
R 50.2.004–2000, GSI. Determination of the Characteristics of Mathematical Models of the Relationships Between Physical Quantities for Solution of Measurement Problems. Basic Assumptions.
R. 50.1.037–2002, Applied Statistics. Rules for Verification of Agreement between Experimental and Theoretical Distributions. Part II. Nonparametric Tests.
GOST 8.061–80, GSI. Verification Schemes. Content and Construction.
S. S. Gogin, “The program MMI-Poverka,” Izmer. Tekhn., No. 7, 20–21 (2006).
I. A. Suleiman, “Method for solving the measurement problem of verifying means of measurement,” Izmer. Tekhn., No. 1, 28–30 (2012).
E. E. Nevskaya, “Program for estimating the reliability of verification of means of measurement,” in: Engineering-Physical Problems in New Technology: Proc 12th All-Russ. Conf.-Seminar, NUK IU MGTU im. Baumana, Moscow (2016), pp. 103–109.
TE1.415313.003RE, DKS-96 Dosimeter-Radiometers, doza.ru>doks/radiation_control/DKS-96_UIK-0.4pdf, acces. May 1, 2016.
GOST 8.033–96, GSI. National Verification Scheme for Means of Measuring Activity of Radionuclides, Flux, and Flux Density of Alpha- and Beta-Particles and Photons from Radionuclide Sources.
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izmeritel’naya Tekhnika, No. 1, pp. 13–15, January, 2017.
Rights and permissions
About this article
Cite this article
Nevskaya, E.E. Evaluating the A Posteriori Reliability of Verification of Means of Measurement of the Characteristics of Ionizing Radiation. Meas Tech 60, 15–18 (2017). https://doi.org/10.1007/s11018-017-1142-2
Received:
Published:
Issue Date: