A version of the basic reference standard of the power of electromagnetic oscillations in coaxial transmission lines in the frequency range 30 MHz–67 GHz is presented. It is shown that through the use of coaxial reference feedthrough wattmeters it is possible to reproduce and disseminate the unit of power of electromagnetic oscillations with the degree of precision necessary for testing the most precise wattmeters.
Similar content being viewed by others
References
V. A. Perepelkin, V. A. Semenov, I. P. Chirkov, and V. G. Chuiko, “State Primary Standard of the unit of power of electromagnetic oscillations in waveguide and coaxial transmission lines in the range of frequencies 0.03–37.5 GHz,” Izmer. Tekhn., No. 1, 7–9 (2012).
J. T. Ashcroft, “Developments in coaxial power standards at NPL,” IEEE Trans. Instrum. Mesaur., 48, No. 2, 647–649 (1999).
M. Bourghes, D. Allal, D. Belieres, and A. Kazemipour, “Development of a 2.4 mm coaxial microcal or i meter for power measurements up to 50 GHz,” CPEM, Daejeon, S. Korea (2010), pp. 324–325.
A. S. Brush, “A new 50 GHz coaxial DC-substitution microwave bolometer,” CPEM, Daejeon, S. Korea (2010), p. 326.
Jae-Yong Kwon, Tae-Won Kang, Jeong-Hwan, and Crowley T. Kim, “Development of a 2.4-mm coaxial microcalorimeter for RF and microwave power standards of KRISS,” CPEM, Washington, USA (2012), pp. 734–735.
J. W. Allen, F. R. Clague, N. T. Larsen, and M. P. Weidmann, “NIST microwave power standard in waveguide,” NIST Tech. Note 1511 (Feb. 1999).
GOST 8.562–2007, GSI. State Measurement Chain for Instruments for the Measurement of the Power and AC Voltage of Sinusoidal Electromagnetic Oscillations.
I. P. Chirkov, “Methods of reducing the error in the dissemination of the unit of UHF power in coaxial transmission lines,” Izmer. Tekhn., No. 1, 56–60 (2012).
I. P. Chirkov, “Calculation of the modulus of the gain factor of segments of a coaxial transmission line in the dissemination of the unit of UHF power with nonexcluded mismatch error,” Metrology in the 21st Century: Proc. Sci. Pract. Conf. Young Scientists, Postgraduates, and Specialists, Mendeleevo (2014), pp. 10–14.
I. P. Chirkov, “A practical method of determining the effective reflectance of the yield of coaxial feedthrough wattmeters,” in: Metrology in the 21st Century: Proc. Sci. Pract. Conf. Young Scientists and Postgraduates, Mendeleevo (2013), pp. 47–52.
GOST 8.381–2009, GSI. Standards. Methods of Expression of Precision.
I. P. Chirkov, “Modern coaxial UHF power calibrators in the range of frequencies to 50 GHz,” Izmer. Teknh., No. 10, 48–52 (2014).
I. P. Chirkov, “Investigations of methods of measuring the modulus of the gain factor of junctions for expanding the range of frequencies of GET 26–2010 in coaxial transmission lines to 50 GHz,” Metrology and Radio Electronics: Proc. Sci. Techn. Conf., Mendeleevo (2014), pp. 76–79.
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izmeritel’naya Tekhnika, No. 9, pp. 61–65, September, 2015.
Rights and permissions