The results of investigations of the oxygen permeability of an analytical solid electrolyte cell with a palladium–palladium oxide medium, which can be used in oxygen gas analyzers, are presented. The mechanism of the electrolytic permeability of oxygen through a solid electrolyte is considered theoretically. The temperature dependence of the oxygen interleakage for zirconia ceramic is determined. The useful working life of a solid electrolyte cell is considered.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. R. L. Pinkhusovich, Analysis of the Metrological Characteristics of Cells with a Solid Electrolyte, Angarsk (1969).

  2. D. P. Podrugin, Investigation and Development of Potentiometer Analyzers of Ultrasmall Concentrations of Oxygen with Solid Electrolyte Cells: Auth. Abstr. Dissert. Cand. Tekhn. Sci., MiKhM, Moscow (1975).

  3. B. J. Fouletier and G. Vitter, Proc. 2nd Int. Meeting on Chemical Sensors, Bordeaux, France (1986).

  4. Yu. A. Lipkin, A. D. Pudalov, and T. S. Voronova, “Investigation of a solid electrolyte cell with a Pd–PdO medium,” Sovrem. Tekh. Sist. Analiz. Modelir., 39, No. 3, 156–159 (2013).

    Google Scholar 

  5. A. A. Vecher and D. V. Vecher, Solid Electrolytes, Minsk (1988).

  6. C. Z. Wagner, “Beitrag zur Theorie des Anlaufvorgangs (Theory of the tarnishing process),” Zeitschr. Phys. Chem. Abt. B: Chem. Elementarproz., Aufbau Mater., No. 21, 25–41 (1933).

  7. A. A. Vecher and D. V. Vecher, Investigation of the Thermodynamic Properties of Materials Using High-Temperature Galvanic Elements and Quantitative Thermographic Analysis: Auth. Abstr. Dissert. Doct. Chem. Sci., Minsk (1973).

  8. J. V. Spirig, R. Ramamoorthya, S. A. Akbar, et al., “High temperature zirconia oxygen sensor with sealed metal/metal oxide internal reference,” Sens. Actuat. B, 124, 192–201 (2007).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. S. Voronova.

Additional information

Translated from Izmeritel’naya Tekhnika, No. 7, pp. 69–72, July, 2015.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Voronova, T.S., Lipnin, Y.A., Mazur, V.G. et al. The Oxygen Permeability of an Analytic Solid-Electrolyte Cell with a Palladium–Palladium Oxide Medium. Meas Tech 58, 829–834 (2015). https://doi.org/10.1007/s11018-015-0802-3

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11018-015-0802-3

Keywords

Navigation